Hima DCS Modules

  1. Home
  2. Products
  3. Hima DCS Modules
  4. HIMA F2108 Fail-safe Delay Module
HIMA F2108 Fail-safe Delay Module

HIMA F2108 Fail-safe Delay Module

0.0
Points

Brand:Hima DCS Modules
Item No.:F2108
Product Origin:Germany
Product Dimensions:150 x 30 x 100 mm
Product Weight:0.231 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

F2108-2F2108-1F2108-3F2108-4

Introduction

The HIMA F2108 Fail-safe Delay Module is a high-integrity timing module for safety-critical applications. It provides precise, configurable delay for outputs, ensuring deterministic and fail-safe operation of relays, actuators, and other safety devices. Its compact, industrial-grade design and seamless integration with HIMA F2 and F2000 systems make it ideal for modular expansion and reliable operation in safety-critical environments.

Technical Specifications

CategoryDetails
Product TypeFail-safe Delay Module
FunctionProvides configurable fail-safe delay for safety outputs
Output TypeRelays, actuators, and other safety-critical devices
CompatibilityHIMA F2 and F2000 safety systems
RedundancySupports fault-tolerant redundant system architectures
ProtectionIsolation, short-circuit, and surge protection
DiagnosticsDelay and output status reporting
Operating EnvironmentIndustrial, high-integrity safety applications
Dimensions150 × 30 × 100 mm
Weight0.231 kg

Recommended Related Models

ModelDescriptionKey Function
F2103aTimer ModuleProvides configurable timing functions for outputs
F2102Safety Related Application ModuleExecutes safety-related output logic
F21014x Relay Amplifier ModuleAmplifies control signals for relays
F2 DO 8 01Safety digital output moduleHigh-integrity 8-channel output control
F2 CPU 01Safety controller CPUExecutes safety logic and monitoring
F2 I/O ExpansionExpansion unitAdds slots for additional I/O modules
F2 Relay 01Relay interface moduleDrives external relays and actuators
F2 Power 01Power supply moduleProvides conditioned power for F2 system
F2 Signal 01Signal conditioning moduleEnsures accurate field signal representation
F2 HMI 01Operator interfaceLocal monitoring and control

Popular Related Models

ModelDescriptionKey Function
F2 DO 16 01Digital output module16-channel high-integrity output control
F2 DI 8 01Digital input module8-channel digital input monitoring
F2 AI 8 01Analog input moduleSafety-critical analog input acquisition
F2 CPU 02Safety controller CPUAdvanced logic processing and redundancy
F2 Comm 02Communication moduleRedundant and secure field communication
F2 Relay 02Relay interface moduleHigh-reliability relay actuation
F2 Power 02Power supply moduleIndustrial-grade conditioned power
F2 HMI 02Operator interfaceLocal system monitoring and control
F2 Signal 02Signal conditionerEnhanced analog/digital signal quality
F2 Expansion 02I/O expansionIncreases module capacity in F2 systems



Applications

The HIMA F2108 Fail-safe Delay Module is engineered for safety-critical industrial automation systems that require precise, fail-safe timing of control actions. It is widely used in oil & gas facilities, chemical plants, power generation, and other high-integrity environments. The module provides controlled delay for safety outputs such as emergency shutdown systems, actuators, and relays, ensuring predictable and safe operation under all conditions.


Advantages

  •  Provides precise, fail-safe delay for safety-critical outputs
  • Ensures deterministic timing in emergency shutdown and safety systems
  • Compact, modular design for easy integration into HIMA F2 and F2000 systems
  • High immunity to electrical noise, transients, and voltage fluctuations
  • Supports redundant and fault-tolerant safety architectures
  • Industrial-grade construction ensures reliable operation under harsh conditions


FAQs

  1.  What is the primary function of the F2108 module? It introduces a controlled, fail-safe delay for safety-critical outputs such as relays and actuators.
  2. Can the delay duration be configured? Yes, the module supports configurable delay times to match system requirements.
  3. Is the module compatible with HIMA F2 safety systems? Yes, it integrates seamlessly with F2 and F2000 architectures.
  4. How does the module ensure fail-safe operation? The internal circuitry guarantees that outputs transition safely in the event of a fault or loss of power.
  5. Can the F2108 be used in redundant system configurations? Yes, it is designed to operate reliably in fault-tolerant redundant safety systems.
  6. What protection features are included for outputs? Each output is isolated and protected against short-circuits and voltage spikes.
  7. Does the module provide diagnostic feedback? Yes, it reports output and delay status to the main safety controller.
  8. What types of devices can the module control? It is suitable for relays, solenoids, actuators, and other safety-critical output devices.
  9. Can the module operate in high-noise industrial environments? Yes, filtering and surge suppression ensure reliable operation even in electrically noisy conditions.
  10. What environmental conditions can the F2108 tolerate? It is rated for operation in industrial conditions with vibration, dust, humidity, and temperature variations.