Brand:Ingersoll Rand Item No.:47579352001 39332333 Product Origin:USA Product Dimensions:109 × 64 × 58 mm Product Weight:0.36 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Ingersoll Rand 47579352001 39332333 8,000-Hour Water-Cooled Service and Two-Position Solenoid Valve Configuration combines a scheduled maintenance package with the specified 39332333 solenoid valve for compatible Sierra oil-free compressor systems. The primary service reference, 47579352001, is associated with the 8,000-hour water-cooled maintenance program, while 39332333 provides electrically controlled valve operation within the applicable compressor circuit.
A correctly functioning solenoid valve is important wherever the compressor relies on electrically controlled flow switching. The normally-open configuration provides a defined default valve state, while electrical actuation allows the compressor control system to change the valve position when required by the operating sequence.
This configuration is intended for professional preventive maintenance and service planning. Before installation, maintenance personnel should verify the compressor model, serial number, valve application, coil voltage, connection arrangement, and current Ingersoll Rand parts documentation.
Technical Specifications
Specification
Details
Brand
Ingersoll Rand
Complete Configuration
47579352001 39332333
Primary Maintenance Reference
47579352001
Maintenance Package
8,000-hour water-cooled maintenance package
Associated Component
39332333
Component Type
Two-position normally-open solenoid valve
Valve Function
Electrically controlled flow switching
Compressor Platform
Sierra 37–75 kW oil-free compressor systems
Cooling Configuration
Water-cooled
Service Interval
8,000 hours
Primary Function
Scheduled maintenance and controlled valve actuation
Installation
Compressor-specific control or flow circuit
Electrical Specification
Verify coil voltage and connector configuration against current parts documentation
Dimensions
Not separately specified for the complete configuration; verify current parts documentation
Weight
Not separately specified for the complete configuration; verify current parts documentation
Compatibility
Verify compressor model, serial number, valve application, electrical requirements, and current parts documentation
Recommended Companion Models
Model
Product Name
L50
Ingersoll Rand Sierra L50 37 kW Oil-Free Rotary Screw Compressor
L60
Ingersoll Rand Sierra L60 45 kW Oil-Free Rotary Screw Compressor
L75
Ingersoll Rand Sierra L75 55 kW Oil-Free Rotary Screw Compressor
L100
Ingersoll Rand Sierra L100 75 kW Oil-Free Rotary Screw Compressor
Frequently Selected Alternatives
Model / Part Number
Product Name
47579611001
Sierra 37–75 8,000-Hour Air-Cooled Maintenance Package
47579185001
Sierra 37–75 4,000-Hour Maintenance Package
47578983001
Sierra 37–75 2,000-Hour Maintenance Package
39332333
Two-Position Normally-Open Solenoid Valve
Where It Excels in Industrial Use
• Designed for scheduled 8,000-hour maintenance on compatible Ingersoll Rand Sierra 37–75 kW oil-free compressor systems in water-cooled configurations.
• Combines the 47579352001 water-cooled maintenance package with the specified 39332333 two-position normally-open solenoid valve as one complete service configuration.
• Supports compressor control circuits that require dependable electrically actuated valve operation for the applicable air, fluid, or control function.
• Well suited to production facilities, process-air installations, utilities, and industrial plants where reliable compressor valve actuation contributes to stable operation.
• Helps maintenance teams coordinate scheduled compressor service with replacement of a specified solenoid valve within the machine's service architecture.
Key Strengths at a Glance
• Water-cooled service focus: 47579352001 provides the scheduled 8,000-hour maintenance reference for applicable Sierra 37–75 kW water-cooled systems.
• Normally-open operation: 39332333 is identified as a two-position normally-open solenoid valve for applicable Ingersoll Rand compressor systems.
• Electrical actuation: The valve provides controlled opening and closing through the compressor's applicable electrical control circuit.
• Integrated maintenance planning: Treating the two references as one complete configuration simplifies preparation for scheduled compressor service.
• Configuration-specific replacement: Correct voltage, connection arrangement, valve function, and compressor application should be confirmed before installation.
Technical FAQs
1. What is the 47579352001 39332333 configuration used for?
It combines the 47579352001 8,000-hour water-cooled maintenance package with the specified 39332333 two-position normally-open solenoid valve as one complete service configuration for compatible Sierra compressor systems.
2. What maintenance interval is associated with 47579352001?
47579352001 is associated with an 8,000-hour scheduled maintenance interval for applicable Sierra 37–75 kW water-cooled compressor configurations.
3. What is the function of 39332333?
39332333 is a two-position normally-open solenoid valve that provides electrically controlled flow through the applicable compressor circuit.
4. What does normally open mean for this solenoid valve?
A normally open valve is designed to remain in its open state when the solenoid is not energized, with electrical actuation used to change the valve to its alternate position.
5. Why is correct solenoid-valve selection important?
The valve must match the required electrical characteristics, flow function, connection arrangement, pressure conditions, and compressor control logic to operate correctly within the intended system.
6. What should be checked before installing 39332333?
The technician should verify the valve part number, coil voltage, electrical connector, flow-path connections, installation orientation, sealing interfaces, and applicable control-circuit requirements.
7. What symptoms can indicate a solenoid-valve problem?
Failure to change position, continuous or interrupted flow, abnormal electrical response, coil overheating, or control-system faults can indicate that the solenoid valve requires inspection.
8. Can another solenoid valve be substituted solely because it has the same connection size?
No. Electrical rating, valve function, normal state, pressure rating, flow characteristics, connection configuration, and control-system compatibility must also be verified.
9. Is 39332333 a complete compressor control system?
No. 39332333 is a solenoid valve component within the applicable compressor system and does not represent the complete control system or controller.
10. What should be verified after installing the solenoid valve?
The technician should confirm secure mechanical and electrical connections, verify correct valve orientation and normal state, test actuation through the applicable control circuit, and inspect the system for leakage or abnormal operation.