Ingersoll Rand

  1. Home
  2. Products
  3. Ingersoll Rand
  4. Ingersoll Rand 47579352001 47578393001 8,000-Hour Water-Cooled Service and Cooler Maintenance Configuration
Ingersoll Rand 47579352001 47578393001 8,000-Hour Water-Cooled Service and Cooler Maintenance Configuration

Ingersoll Rand 47579352001 47578393001 8,000-Hour Water-Cooled Service and Cooler Maintenance Configuration

0.0
Points

Brand:Ingersoll Rand
Item No.:47579352001 47578393001
Product Origin:USA
Product Dimensions:110 × 66.8 × 50 mm
Product Weight:0.08 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

24509200-224509200-124509200-424509200-3

Introduction

The Ingersoll Rand 47579352001 47578393001 8,000-Hour Water-Cooled Service and Cooler Maintenance Configuration combines two service references for compatible Sierra 37–75 kW oil-free rotary screw compressors. The primary reference, 47579352001, is specified as an 8,000-hour water-cooled maintenance kit, while 47578393001 provides the associated cooler maintenance reference.

Cooler condition is an important part of compressor thermal management. In a water-cooled installation, effective heat transfer depends on the condition of the cooler assembly, its internal passages, sealing interfaces, and associated cooling circuit. Scheduled maintenance helps identify contamination, fouling, leakage, or component deterioration before these conditions interfere with normal compressor operation.

This complete configuration is intended to simplify planned service preparation for compatible Sierra equipment. The exact compressor model, cooling arrangement, serial number, and current parts documentation should be confirmed before installation because service requirements can vary between equipment configurations.

Technical Specifications

SpecificationDetails
BrandIngersoll Rand
Complete Configuration47579352001 47578393001
Primary Maintenance Reference47579352001
Primary Package Type8,000-hour water-cooled maintenance kit
Associated Service Reference47578393001
Associated Component TypeCooler maintenance package
Compressor PlatformSierra 37–75 kW oil-free rotary screw compressors
Cooling ConfigurationWater-cooled
Service Interval8,000 hours
Primary FunctionScheduled compressor maintenance and cooler servicing
Thermal Management FunctionSupport of cooler condition and heat-transfer performance
ApplicationIndustrial oil-free compressed-air systems
InstallationCompressor-specific water-cooled cooler assembly
DimensionsNot separately specified for the complete 47579352001 47578393001 configuration; verify current parts documentation
WeightNot separately specified for the complete 47579352001 47578393001 configuration; verify current packing or parts documentation
CompatibilityVerify compressor model, serial number, cooling arrangement, and current service documentation

Recommended Companion Models

ModelProduct Name
L50Ingersoll Rand Sierra 37 kW oil-free rotary screw compressor
L60Ingersoll Rand Sierra 45 kW oil-free rotary screw compressor
L75Ingersoll Rand Sierra 55 kW oil-free rotary screw compressor
L100Ingersoll Rand Sierra 75 kW oil-free rotary screw compressor

Frequently Selected Alternatives

Model / Part NumberTypical Use
47579185001Sierra 37–75 4,000-hour maintenance package
47578983001Sierra 37–75 2,000-hour maintenance package
47579611001Sierra 37–75 8,000-hour air-cooled maintenance package
47578393001Cooler maintenance package for applicable Sierra compressor configurations


Where It Excels in Industrial Use

• Designed for scheduled 8,000-hour maintenance on compatible Ingersoll Rand Sierra 37–75 kW oil-free rotary screw compressor systems.

• Combines the 47579352001 water-cooled maintenance kit with the specified 47578393001 cooler maintenance package as one complete service configuration.

• Supports maintenance programs where cooler condition, heat-transfer performance, sealing integrity, and scheduled service requirements must be managed together.

• Well suited to industrial compressed-air installations in manufacturing, process, electronics, pharmaceutical, food and beverage, and other applications requiring oil-free compressed air.

• Helps maintenance teams coordinate major scheduled service work with cooler-related maintenance rather than treating thermal-management components as an unrelated task.


Key Strengths at a Glance

Integrated maintenance configuration: 47579352001 and 47578393001 provide a combined reference for planned 8,000-hour service and cooler maintenance.

Water-cooled application: The primary 47579352001 package is specified for Sierra 37–75 water-cooled compressor configurations.

Cooler service support: 47578393001 is identified as a cooler maintenance package for the applicable compressor platform.

Thermal-performance focus: Proper cooler maintenance supports heat transfer and helps maintain compressor operating temperatures within the intended range.

Scheduled service planning: The configuration provides a structured reference for coordinating long-interval maintenance activities on compatible Sierra equipment.


Technical FAQs

1. What does the 47579352001 47578393001 configuration represent?

It represents a complete requested maintenance configuration combining the 8,000-hour water-cooled service kit 47579352001 with the specified cooler maintenance package 47578393001.

2. Which compressor platform is associated with 47579352001?

47579352001 is specified as an 8,000-hour water-cooled maintenance kit for Ingersoll Rand Sierra 37–75 compressor systems.

3. What is the purpose of 47578393001?

47578393001 is a cooler maintenance package intended to support service of the applicable compressor cooling assembly and its associated maintenance requirements.

4. Why is cooler maintenance important on a water-cooled compressor?

The cooler is part of the compressor's thermal-management system, so maintaining its heat-transfer surfaces, seals, and related service components helps support stable operating temperatures.

5. Does 47578393001 replace the complete cooler assembly?

No. It should be treated as a maintenance package for the applicable cooler system rather than automatically as a replacement for the complete cooler assembly.

6. What should be checked before installing the cooler maintenance package?

The compressor model, serial number, cooler configuration, existing cooler assembly, and current Ingersoll Rand parts documentation should be verified before installation.

7. Can the 47579352001 service kit be used on air-cooled Sierra models?

47579352001 is specifically identified as a water-cooled maintenance kit, so the compressor cooling configuration should be confirmed before ordering or installation.

8. What conditions can affect cooler service requirements?

Cooling-water quality, contamination, operating temperature, fouling, corrosion, pressure conditions, and the general condition of the cooler circuit can influence maintenance requirements.

9. What should be inspected during cooler maintenance?

Technicians should inspect cooler surfaces, sealing interfaces, connections, water passages, associated piping, and evidence of leakage or contamination in accordance with the applicable maintenance procedure.

10. What should be recorded after completing this service configuration?

The maintenance record should document the compressor operating hours, service date, installed part numbers, cooler maintenance performed, inspection findings, and any corrective work completed.