Ingersoll Rand 47625673001 23650633 8,000-Hour Maintenance and Check Valve Configuration
Ingersoll Rand 47625673001 23650633 8,000-Hour Maintenance and Check Valve Configuration
0.0
Points
Brand:Ingersoll Rand Item No.:47625673001 23650633 Product Origin:USA Product Dimensions:108 × 7.2 × 7.2 mm Product Weight:0.36 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Ingersoll Rand 47625673001 23650633 8,000-Hour Maintenance and Check Valve Configuration combines the 47625673001 scheduled maintenance reference with the specified 23650633 check valve. Parts listings identify 47625673001 as an 8,000-hour air-cooled maintenance package, while 23650633 is identified as a check-valve reference used in applicable Ingersoll Rand compressor equipment.
The check valve contributes to controlled one-way flow within the compressor discharge system. Maintaining the valve and associated connections in proper condition helps support the intended pressure-flow relationship and reduces the risk of unwanted reverse flow.
This complete configuration is intended to simplify preventive-maintenance planning and parts identification. Because valve applications can vary by compressor generation and configuration, the compressor model, serial number, connection arrangement, and current parts documentation should be verified before installation.
Technical Specifications
Specification
Details
Brand
Ingersoll Rand
Complete Configuration
47625673001 23650633
Primary Maintenance Reference
47625673001
Valve Reference
23650633
Primary Product Type
8,000-Hour Maintenance and Check Valve Configuration
Maintenance Interval
8,000 hours
Maintenance Package Type
Air-cooled maintenance package
Component Type
Check Valve / Discharge Check Valve
Primary Function
One-way compressed-air flow control
Application
Compatible Ingersoll Rand compressor systems
Installation
Compressor discharge circuit, subject to exact configuration verification
Service Purpose
Scheduled preventive maintenance and valve replacement
Operating Environment
Industrial compressed-air installations
Dimensions
Not separately specified for the complete 47625673001 23650633 configuration; verify current parts documentation
Weight
Not separately specified for the complete 47625673001 23650633 configuration; verify current parts documentation
Compatibility
Verify compressor model, serial number, valve arrangement, and current parts documentation before installation
Recommended Companion Models
Model
Product Name
S90
Ingersoll Rand Sierra S90 oil-free rotary screw compressor
S110
Ingersoll Rand Sierra S110 oil-free rotary screw compressor
S132
Ingersoll Rand Sierra S132 oil-free rotary screw compressor
S150
Ingersoll Rand Sierra S150 oil-free rotary screw compressor
Frequently Selected Alternatives
Model / Part Number
Product Name
47625671001
Sierra S90 2,000-Hour Maintenance Package
47625672001
Sierra S90 4,000-Hour Maintenance Package
47625674001
Sierra S90 8,000-Hour Water-Cooled Maintenance Package
23650619
Ingersoll Rand Check Valve Reference for Applicable Compressor Systems
Where It Excels in Industrial Use
• Designed around the 8,000-hour air-cooled maintenance package 47625673001 for applicable Ingersoll Rand compressor systems.
• Combines 47625673001 with the specified 23650633 check valve as one complete service configuration for planned maintenance and component replacement.
• Supports industrial compressed-air installations where scheduled service and reliable discharge-flow control are important to compressor operation.
• Provides maintenance teams with a consolidated reference for long-interval servicing and inspection of the associated check-valve assembly.
• Well suited to production environments where maintaining correct valve operation helps support stable compressor pressure and controlled airflow.
Key Strengths at a Glance
• 8,000-hour service basis: 47625673001 is identified as an 8,000-hour air-cooled maintenance package.
• Discharge check-valve function: 23650633 is identified in parts listings as a check valve and is also described as a discharge check-valve replacement.
• Flow-control support: The valve helps prevent unintended reverse flow within the applicable compressor discharge circuit.
• Long-interval maintenance planning: The configuration combines the scheduled maintenance reference with a specified valve component for service preparation.
• Application verification: The complete configuration should be matched against the compressor model, serial number, valve arrangement, and current parts documentation before installation.
Technical FAQs
1. What is the 47625673001 23650633 configuration used for?
It combines the 8,000-hour air-cooled maintenance package reference 47625673001 with the specified 23650633 check valve as one complete maintenance configuration.
2. What maintenance interval is associated with 47625673001?
47625673001 is identified as an 8,000-hour air-cooled maintenance package for the applicable compressor configuration.
3. What is 23650633?
23650633 is an Ingersoll Rand check-valve reference and is identified in parts listings as a discharge check valve for applicable compressor equipment.
4. What function does a discharge check valve provide?
A discharge check valve permits compressed air to flow in the intended direction while helping prevent reverse flow when pressure conditions change or the compressor stops.
5. Why is correct check-valve operation important?
A properly functioning check valve helps maintain the intended discharge-flow path and can reduce unwanted pressure reversal or backflow within the compressor system.
6. What symptoms can indicate a check-valve problem?
Abnormal pressure behavior, unexpected reverse flow, unusual discharge-side noise, or changes in compressor shutdown behavior can indicate that the valve and associated circuit require inspection.
7. What should be checked before installing 23650633?
The technician should verify the compressor identification, valve part number, connection arrangement, flow direction, sealing surfaces, and current equipment-specific service documentation.
8. Can 23650633 be substituted solely because another valve has similar dimensions?
No. Valve selection should also account for flow direction, pressure rating, connection configuration, operating conditions, and compressor-specific application.
9. What operating conditions can affect check-valve service life?
Frequent cycling, contamination, pressure fluctuations, elevated operating temperatures, and abnormal flow conditions can contribute to valve wear or impaired sealing.
10. What should be recorded after completing the service?
The maintenance record should include the compressor operating hours, service date, installed part numbers, valve condition, and any abnormal pressure or flow conditions identified during inspection.