Allen Bradley 1420-V2P-ENT Powermonitor 500 Ethernet Power Meter
Allen Bradley 1420-V2P-ENT Powermonitor 500 Ethernet Power Meter
0.0
Points
Brand:Allen Bradley PLC Item No.:1420-V2P-ENT Product Origin:USA Product Dimensions:89.5 x 20 x 63 mm Product Weight:0.4 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Allen Bradley 1420-V2P-ENT PowerMonitor 500 Ethernet Power Meter provides a compact method of integrating electrical power measurement into industrial automation and monitoring systems. Rather than treating electrical consumption as an isolated utility parameter, the meter allows power information to become part of a broader plant information architecture.
In manufacturing environments, electrical demand can vary significantly with machine loading, production schedules, process conditions, and equipment status. Monitoring these changes gives engineers additional information when evaluating equipment performance and energy usage.
The 1420-V2P-ENT is designed for installations where both measurement capability and compact physical dimensions are important. Its 89.5 × 20 × 63 mm size makes it suitable for space-conscious control panels and electrical assemblies.
Ethernet connectivity also makes the PowerMonitor 500 useful for distributed monitoring. Power information from equipment or electrical sections can be incorporated into an industrial network and used alongside other automation data for operational analysis, maintenance activities, and energy-management programs.
Technical Specifications
Specification
Details
Brand
Allen Bradley
Model
1420-V2P-ENT
Product Family
PowerMonitor 500
Product Type
Ethernet Power Meter
Communication
Ethernet
Application
Industrial Power Monitoring
Dimensions
89.5 × 20 × 63 mm
Weight
0.4 kg (0.88 lb)
Installation
Industrial Control / Electrical Panel
Recommended Related Models
Model
Product Type
1420-V1P-ENT
PowerMonitor 500 Ethernet Power Meter
1420-V2P-ENT1
PowerMonitor 500 Power Meter
1420-V1P-ENT1
PowerMonitor 500 Power Meter
1420-V2P-ENT
PowerMonitor 500 Ethernet Power Meter
1408-TS3A-18B
PowerMonitor Power Monitoring Module
Popular Related Models
Model
Product Type
1408-EM3A-ENT
PowerMonitor Energy Monitor
1408-TR2A-ENT
PowerMonitor Energy Monitor
1408-TS3A-18B
PowerMonitor Power Monitor
1408-BC3A-ENT
PowerMonitor Communication Module
1420-V1P-ENT
PowerMonitor 500 Ethernet Power Meter
1420-V2P-ENT1
PowerMonitor 500 Power Meter
Applications
The Allen Bradley 1420-V2P-ENT PowerMonitor 500 is an Ethernet-enabled power meter designed for monitoring electrical parameters in industrial automation and power distribution systems. It provides a compact solution for bringing electrical measurement data into control, energy-management, and plant-monitoring applications.
The meter can be used around production equipment, machine control panels, electrical distribution systems, and facility utilities where engineers need better visibility into power usage and operating conditions.
Typical applications include:
Industrial power monitoring
Machine and production-line energy measurement
Electrical distribution monitoring
Factory energy-management systems
Control-panel power measurement
Utility and facility monitoring
Equipment load analysis
Industrial Ethernet monitoring architectures
Advantages
Compact Power Monitoring Solution
The 1420-V2P-ENT combines power measurement and Ethernet connectivity in a compact device. Its small footprint makes it practical for control panels and electrical assemblies with limited available space.
Ethernet-Based Data Access
With Ethernet communication, electrical measurement information can be incorporated into a plant network and accessed by compatible automation or supervisory systems.
Useful for Energy Management
Power data can help engineering and maintenance teams understand equipment consumption, identify changing load conditions, and support plant energy-management activities.
Integration with Industrial Automation
The meter can be incorporated into automation architectures where electrical measurements need to be considered alongside PLC, HMI, process, and equipment information.
Lightweight Panel Installation
The unit measures 89.5 × 20 × 63 mm and weighs only 0.4 kg, making it suitable for compact electrical and automation installations.
Technical FAQs
1. What is the Allen Bradley 1420-V2P-ENT used for?
The 1420-V2P-ENT is a PowerMonitor 500 Ethernet power meter used to monitor electrical power parameters and provide measurement information for industrial monitoring and energy-management applications.
2. What is the purpose of Ethernet communication on the 1420-V2P-ENT?
Ethernet communication allows the meter to exchange measurement information with compatible industrial monitoring, automation, and supervisory systems.
3. Where is the PowerMonitor 500 typically used?
It can be installed in industrial control panels, electrical distribution systems, production equipment, manufacturing lines, and facility power-monitoring applications.
4. Can the 1420-V2P-ENT be incorporated into an Allen Bradley automation system?
Yes. Its Ethernet capability allows it to serve as an electrical monitoring component within compatible industrial automation and network architectures.
5. How can power monitoring help manufacturing operations?
Electrical measurements can provide information about equipment loading and consumption. Engineers can use this information to analyze operating conditions, compare production periods, and identify unusual changes in electrical behavior.
6. Can the meter be used for machine-level energy monitoring?
Yes. It can be applied to individual machines or equipment groups where electrical consumption and operating parameters need to be monitored as part of an industrial energy-management strategy.
7. What should be checked if Ethernet communication is unavailable?
Check the meter's power supply, Ethernet cable, connectors, network port, communication settings, and the configuration of the connected automation or monitoring system.
8. What factors should be considered when installing the meter?
The electrical system characteristics, measurement wiring, installation environment, network requirements, protection arrangements, and applicable electrical installation practices should be reviewed before commissioning.
9. How can abnormal power readings be investigated?
Start by checking the measurement wiring and electrical connections. Then verify the meter configuration and compare the readings with expected system values or an appropriate reference measurement.
10. Can the 1420-V2P-ENT support long-term energy monitoring?
It can be incorporated into systems that collect and analyze electrical measurement information over time, allowing users to study consumption patterns and equipment operating behavior.