Brand:Schneider PLC Item No.:MT08N1 Product Origin:France Product Dimensions:301 x 276 x 196 mm Product Weight:14 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Schneider MT08N1 Circuit Breaker is identified as a circuit protection component for electrical distribution applications. In industrial electrical systems, circuit breakers provide switching capability and help interrupt current when specified fault conditions occur.
Selecting a suitable breaker requires evaluating the electrical characteristics of the installation. Rated current, operating voltage, short-circuit breaking capacity, trip characteristics, pole configuration, and compatibility with the existing switchgear are important factors in determining whether a device is appropriate for a particular application.
The supplied dimensions for the MT08N1 are 301 × 276 × 196 mm, and the stated weight is 14 kg. These specifications can assist with preliminary enclosure-space assessment, handling arrangements, and replacement planning. The complete electrical ratings should be confirmed before procurement or installation.
Technical Specifications
Parameter
Specification
Brand
Schneider Electric
Model
MT08N1
Product Type
Circuit Breaker
Dimensions
301 × 276 × 196 mm
Dimensions (inches)
11.85 × 10.87 × 7.72 in
Weight
14.00 kg / 30.86 lb
Application
Electrical power distribution and circuit protection
Rated Current
Not provided
Rated Voltage
Not provided
Number of Poles
Not provided
Breaking Capacity
Not provided
Trip Unit
Not provided
Mounting Configuration
To be verified
Note: Dimensions and weight are reproduced from the supplied information. Confirm the dimension order, exact product designation, and electrical ratings against the product nameplate before ordering or installation.
Recommended Related Models
The following Schneider Electric circuit breaker product families may be useful for comparison. They are not confirmed direct replacements for the MT08N1.
Model / Series
Product Type
Schneider Electric MasterPact MTZ
Low-Voltage Air Circuit Breaker Series
Schneider Electric MasterPact NT
Low-Voltage Air Circuit Breaker Series
Schneider Electric MasterPact NW
Low-Voltage Air Circuit Breaker Series
Schneider Electric ComPact NS
Molded-Case Circuit Breaker Series
Schneider Electric ComPact NSX
Molded-Case Circuit Breaker Series
Popular Related Models
Model / Series
Product Type
Schneider Electric MasterPact MTZ1
Air Circuit Breaker
Schneider Electric MasterPact MTZ2
Air Circuit Breaker
Schneider Electric MasterPact NT
Air Circuit Breaker
Schneider Electric MasterPact NW
Air Circuit Breaker
Schneider Electric ComPact NSX
Molded-Case Circuit Breaker
Schneider Electric ComPact NS
Molded-Case Circuit Breaker
Applications
The Schneider MT08N1 Circuit Breaker is identified by the supplied product name as a circuit breaker for electrical power distribution and circuit protection applications. In industrial environments, circuit breakers provide switching functionality and help interrupt current under specified fault conditions. The exact electrical ratings and configuration of the MT08N1 should be verified before installation or replacement.
Industrial Power Distribution: Supports circuit protection in compatible electrical distribution assemblies.
Manufacturing Facilities: Can be evaluated for electrical systems supplying machinery, production lines, and industrial equipment.
Switchgear Integration: May be considered for compatible switchgear installations after confirming mounting arrangements and electrical ratings.
Electrical Equipment Protection: Helps interrupt specified fault currents when correctly selected for the circuit.
Maintenance and Replacement: Supports maintenance planning where the exact model and configuration have been confirmed.
Electrical System Upgrades: Can be evaluated for projects requiring a compatible circuit breaker within an existing distribution system.
Advantages
1. Circuit Protection Function
Circuit breakers help protect electrical circuits by interrupting current under specified abnormal conditions within their rated operating limits.
2. Controlled Switching
A circuit breaker provides a means of switching an electrical circuit, supporting operating procedures and maintenance activities.
3. Industrial Integration
The MT08N1 can be assessed for compatible electrical installations once its rated current, operating voltage, and breaking capacity have been confirmed.
4. Practical Installation Planning
The supplied dimensions of 301 × 276 × 196 mm provide a reference for checking enclosure space, mounting arrangements, and installation clearances.
5. Maintenance Support
Accurate model identification helps maintenance teams select replacement equipment and reduce the risk of component mismatches.
6. Protection Coordination
Selecting suitable trip characteristics and breaking capacity helps coordinate the breaker with other protective devices in the electrical distribution system.
Technical FAQs
Q1: What is the primary function of the Schneider MT08N1 Circuit Breaker?
Its stated product category is a circuit breaker. Circuit breakers are designed to switch electrical circuits and interrupt current under specified fault conditions according to their design and ratings.
Q2: What types of electrical faults can a circuit breaker interrupt?
Depending on its design, a circuit breaker can interrupt overload and short-circuit currents. The exact protection functions of the MT08N1 should be confirmed from the applicable technical documentation.
Q3: Is the MT08N1 compatible with every electrical distribution panel?
No. Compatibility depends on the panel design, mounting arrangement, terminal configuration, voltage and current ratings, breaking capacity, and required clearances.
Q4: Why must rated current be checked before installation?
The rated current must match the requirements of the protected circuit, conductors, and connected equipment. Incorrect selection can result in inadequate protection or unwanted tripping.
Q5: What does breaking capacity mean?
Breaking capacity is the maximum prospective fault current a breaker can safely interrupt under specified conditions. It must be suitable for the expected short-circuit current at the installation point.
Q6: What is the difference between overload and short-circuit protection?
Overload protection addresses excessive current that persists over time, while short-circuit protection addresses high fault currents that can develop rapidly. Available functions depend on the breaker's design and trip mechanism.
Q7: What might cause repeated circuit breaker tripping?
Possible causes include excessive load, short circuits, faulty downstream equipment, unsuitable protection settings, or an incorrectly selected breaker. The underlying issue should be identified before restoring power.
Q8: What should be inspected during routine maintenance?
Follow the manufacturer's instructions and applicable electrical safety procedures. Depending on the design, inspections may include terminals, mounting hardware, signs of overheating, insulation condition, mechanical operation, and trip-unit indicators.
Q9: Can the MT08N1 replace another breaker with similar dimensions?
Not necessarily. Replacement compatibility also depends on electrical ratings, breaking capacity, pole configuration, mounting requirements, terminal arrangements, and accessory compatibility.
Q10: What details should be verified before purchasing the MT08N1?
Confirm the full model designation, rated current, rated voltage, number of poles, breaking capacity, trip-unit configuration, mounting requirements, and accessory compatibility using the product nameplate or applicable technical documentation.