Brand:Schneider PLC Item No.:MTE06N Product Origin:France Product Dimensions:301 x 346 x 196 mm Product Weight:18 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Schneider MTE06N Breaker is a model-specific circuit protection component to evaluate for suitable electrical distribution applications. Correct breaker selection is important for protecting connected equipment, maintaining a coordinated protection system, and ensuring compatibility with the existing electrical installation.
For industrial maintenance teams and equipment buyers, confirming the exact model and configuration before ordering can help prevent mismatches during replacement or commissioning. Electrical ratings, connection arrangements, mounting requirements, and accessory options should all be checked against the intended application.
Whether sourcing a unit for planned maintenance, spare-parts inventory, or an equipment refurbishment project, verify the product nameplate and applicable technical documentation before purchase. This helps establish a reliable basis for selecting the appropriate breaker.
Technical Specifications
Parameter
Specification
Brand
Schneider Electric
Model
MTE06N
Product Type
Circuit Breaker
Product Category
Electrical Power Distribution and Protection
Dimensions
301 × 346 × 196 mm
Shipping Weight
18 kg / 39.68 lb
Application
Electrical distribution and circuit protection
Rated Voltage
Verify against the product nameplate
Rated Current
Verify against the product nameplate
Breaking Capacity
Verify against the product documentation
Pole Configuration
Confirm the exact version
Trip Unit
Confirm the installed configuration
Accessories
Subject to model compatibility
Installation
According to the confirmed product specifications and system design
Recommended Related Models
The following Schneider Electric circuit breaker models and product families may be useful when comparing requirements for electrical distribution projects. They are not confirmed direct replacements for the MTE06N.
Schneider MVS08N Breaker — A model to review when comparing circuit protection requirements in distribution systems.
Schneider MVS10N Breaker — Another model designation for equipment sourcing and specification comparison.
Schneider MVS12N Breaker — May be considered during a broader review of Schneider circuit breaker options.
Schneider MVS16N Breaker — A related model designation to evaluate against the installation's electrical and mechanical requirements.
Verify the complete model number, ratings, mounting configuration, and terminal arrangement before choosing an alternative.
Popular Related Models
Other Schneider Electric circuit breaker product families that may be relevant to industrial procurement include:
Schneider Masterpact MTZ Circuit Breakers
Schneider Masterpact NW Circuit Breakers
Schneider Masterpact NT Circuit Breakers
Schneider Compact NSX Circuit Breakers
These families serve different application and rating requirements. Confirm suitability and compatibility before using any model as an alternative to the MTE06N.
Applications
The Schneider MTE06N Breaker is identified by its model designation as a circuit breaker for electrical distribution applications. When selecting this unit for an industrial installation, its electrical ratings and configuration should be verified to ensure that it meets the system's protection and operating requirements.
Potential application areas include:
Industrial Power Distribution: Supports circuit protection arrangements in suitable electrical distribution systems.
Control and Distribution Panels: May be considered for compatible panel assemblies where its mounting and connection requirements are satisfied.
Manufacturing Facilities: Can be evaluated for electrical systems supplying industrial machinery and auxiliary equipment.
Facility Electrical Maintenance: May be considered during equipment replacement or distribution system refurbishment.
Spare Parts Procurement: Provides a specific model designation for sourcing and inventory identification.
Before installation, confirm the MTE06N's rated current, operating voltage, breaking capacity, pole configuration, and compatibility with the intended electrical assembly.
Advantages
Selecting a circuit breaker that matches the system's electrical and mechanical requirements is essential for dependable power distribution. The Schneider MTE06N Breaker can be evaluated as part of a properly specified protection arrangement.
Circuit Protection: Supports protection against specified electrical fault conditions when correctly rated and configured.
System Integration: Can be assessed for installation in compatible electrical distribution assemblies.
Equipment Replacement Planning: The model designation helps procurement and maintenance teams identify the intended component.
Maintenance Efficiency: Accurate configuration checks can help reduce replacement errors and installation delays.
Industrial Procurement Support: Suitable for evaluation in spare-parts sourcing and electrical equipment maintenance workflows.
Application-Based Selection: Allows buyers to compare the unit's verified technical characteristics with project requirements.
Actual protection performance depends on the confirmed breaker specifications, installation conditions, and coordination with other protective devices.
Technical FAQs
Q1: What is the Schneider MTE06N Breaker used for?
It is identified as a circuit breaker. Its specific application depends on its verified electrical ratings, configuration, and the requirements of the distribution system.
Q2: What should I check before ordering this breaker?
Confirm the complete model number, rated operational voltage, rated current, short-circuit breaking capacity, number of poles, and connection arrangement.
Q3: How do I determine whether the breaker is suitable for my electrical system?
Compare its nameplate ratings with the system voltage, expected load current, and prospective short-circuit current. Suitability should be established by a qualified electrical professional.
Q4: Can the MTE06N replace another Schneider circuit breaker?
Not necessarily. Similar-looking breakers may have different ratings, mounting arrangements, terminal configurations, or protection characteristics. Verify compatibility before replacement.
Q5: What is the difference between rated current and breaking capacity?
Rated current describes the current the breaker is designed to carry under specified conditions. Breaking capacity describes the fault current it can interrupt under defined test conditions.
Q6: What role does a trip unit play in circuit protection?
A trip unit detects specified abnormal current conditions and initiates the opening of the breaker when its protection criteria are met. The available functions depend on the particular design and configuration.
Q7: Does the MTE06N support auxiliary contacts or other accessories?
Accessory availability must be confirmed for the exact model and version. Check the product configuration before ordering auxiliary contacts or additional components.
Q8: How should the breaker be coordinated with other protective devices?
Coordination requires comparing protection characteristics, fault-current levels, and the requirements of upstream and downstream equipment. The complete protection scheme should be assessed by a qualified engineer.
Q9: What inspections are recommended during maintenance?
Follow the manufacturer's maintenance instructions. Typical checks may include examining terminals, connections, the operating mechanism, insulation, and visible signs of overheating or damage.
Q10: What information helps confirm a compatible replacement?
Provide the complete model designation, nameplate information, electrical ratings, trip unit details, terminal arrangement, and any installed accessories. Photographs of the existing breaker can also assist identification.