Allen Bradley PLC

  1. Home
  2. Products
  3. Allen Bradley PLC
  4. Allen Bradley 1788-EN2PAR Redundant EtherNet/IP to Profibus PA Gateway
Allen Bradley 1788-EN2PAR Redundant EtherNet/IP to Profibus PA Gateway

Allen Bradley 1788-EN2PAR Redundant EtherNet/IP to Profibus PA Gateway

0.0
Points

Brand:Allen Bradley PLC
Item No.:1788-EN2PAR
Product Origin:USA
Product Dimensions:152 x 80 x 136 mm
Product Weight:0.54 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart


Introduction

The Allen Bradley 1788-EN2PAR Redundant EtherNet/IP to PROFIBUS PA Gateway is an industrial network integration product intended to support communication between EtherNet/IP-based control systems and PROFIBUS PA process instrumentation.

In process automation, control systems often need to exchange data with field devices that use different communication technologies. A suitable gateway can provide an interface between these networks, helping engineers integrate instrument information into control and monitoring applications. This can be especially useful when a facility is upgrading its automation architecture while retaining compatible field instrumentation.

For system integrators, maintenance engineers, and industrial equipment buyers, selecting the correct gateway requires verification of protocol compatibility, redundancy requirements, supported devices, configuration tools, and network architecture. The term “redundant” in the model description should not be treated as a guarantee of complete end-to-end network redundancy; the overall system design and supported operating modes must be confirmed.

The supplied dimensions of 152 × 80 × 136 mm and weight of 0.54 kg provide useful preliminary information for cabinet planning, handling, and logistics. Before installation or replacement, consult the exact product documentation to confirm mounting, power, wiring, and configuration requirements.

Technical Specifications

Parameter

Specification

Brand

Allen Bradley

Model

1788-EN2PAR

Product Type

Redundant EtherNet/IP to PROFIBUS PA Gateway

EtherNet/IP Interface

Confirm the exact interface specifications in the product documentation

PROFIBUS PA Interface

Confirm supported segment and device requirements

Redundancy Function

Verify supported redundancy architecture and operating modes

Dimensions (W × H × D)

152 × 80 × 136 mm

Weight

0.54 kg / 1.19 lb

Power Requirements

Verify from the product nameplate and installation manual

Configuration

Confirm supported software and firmware versions

Mounting Requirements

Verify the specified mounting method and clearances

Environmental Ratings

Confirm the manufacturer's specified operating conditions

Typical Application

Industrial network integration and process instrumentation communication

Technical note: Dimensions and weight are based on the supplied product information. Confirm interface details, power requirements, redundancy behavior, firmware compatibility, and environmental specifications against the exact unit before purchase or commissioning.

Recommended Related Models

The following Allen Bradley product families and gateway-related designations may be relevant when evaluating industrial network integration requirements. Their functions and compatibility should be confirmed before selecting an alternative.

  • Allen Bradley 1788-EN2PAR — The specified gateway model for EtherNet/IP and PROFIBUS PA integration.

  • Allen Bradley 1788-EN2DN — A network interface product designation to investigate when reviewing EtherNet/IP integration requirements.

  • Allen Bradley 1756-EN2TR — An EtherNet/IP communication module used in compatible ControlLogix architectures; it is not a direct substitute for the 1788-EN2PAR.

  • Allen Bradley 1756-EN2T — An EtherNet/IP communication module for compatible ControlLogix systems; verify the intended network role before comparison.

  • Allen Bradley 1756-L83E — A ControlLogix controller model that may be relevant to broader EtherNet/IP system planning, subject to project requirements.

Popular Related Models

These Allen Bradley products may also be of interest when sourcing communication and network-integration equipment for industrial automation projects:

  • Allen Bradley 1756-EN2TR EtherNet/IP Communication Module

  • Allen Bradley 1756-EN2T EtherNet/IP Communication Module

  • Allen Bradley 1756-EN3TR EtherNet/IP Communication Module

  • Allen Bradley 1756-L83E ControlLogix Controller

  • Allen Bradley 1788-EN2PAR Redundant EtherNet/IP to PROFIBUS PA Gateway

The products listed above serve different roles within an automation architecture and should not be considered interchangeable. Before purchasing a replacement or alternative, verify the exact catalog number, supported protocols, redundancy functions, controller compatibility, configuration requirements, and network design.


Applications

The Allen Bradley 1788-EN2PAR Redundant EtherNet/IP to PROFIBUS PA Gateway is designed for industrial automation architectures that need to connect EtherNet/IP-based control systems with PROFIBUS PA field instrumentation. It supports communication between different industrial network environments, helping integrate process instruments into a broader control and monitoring system.

Typical application areas include:

  • Process automation: Connecting compatible PROFIBUS PA field devices with EtherNet/IP-based automation systems.

  • Distributed control systems: Supporting communication between process instrumentation and control-system infrastructure.

  • Industrial network integration: Bridging compatible fieldbus and Ethernet-based control networks.

  • Instrumentation modernization: Helping integrate existing PROFIBUS PA devices into an automation architecture that uses EtherNet/IP.

  • Chemical and pharmaceutical facilities: Supporting network integration for process instrumentation when the selected configuration meets site requirements.

  • Oil, gas, and energy installations: Providing a potential communication interface for compatible field instruments in appropriately engineered systems.

  • Industrial maintenance and upgrades: Supporting replacement planning and network architecture reviews for existing automation installations.

Before deployment, confirm compatibility with the installed controller, network topology, PROFIBUS PA segment design, gateway configuration, and applicable hazardous-area requirements.


Advantages

1. Integration Between Industrial Networks

The 1788-EN2PAR is intended to bridge EtherNet/IP and PROFIBUS PA communication environments, helping automation engineers connect compatible control equipment and process instrumentation.

2. Support for Process Instrumentation

PROFIBUS PA is commonly used for process field devices such as transmitters and other instruments. A suitable gateway can help make compatible device information available to the control system.

3. Reduced Network Integration Complexity

Using an appropriate protocol gateway can simplify communication between network technologies that would otherwise require separate interfaces or a different integration approach.

4. Suitable for Industrial Automation Architectures

The gateway can be evaluated for applications involving PLC-based control, process instrumentation, and industrial network infrastructure, subject to confirmed configuration and compatibility.

5. Useful for System Upgrades

When modernizing an existing control system, engineers can assess whether a gateway-based architecture offers a practical way to retain compatible field devices while integrating them with an EtherNet/IP environment.

6. Compact Installation Footprint

The supplied dimensions of 152 × 80 × 136 mm help engineers estimate mounting space and plan cabinet layouts. Actual clearances, mounting requirements, and wiring access should be checked before installation.

7. Easier Spare-Parts Identification

Using the complete Allen Bradley model number, 1788-EN2PAR, helps maintenance teams and procurement specialists identify the intended product when requesting quotations or planning replacements.


Technical FAQs

Q1: What is the Allen Bradley 1788-EN2PAR used for?

It is identified as a redundant EtherNet/IP-to-PROFIBUS PA gateway. Its intended role is to support communication between compatible EtherNet/IP control infrastructure and PROFIBUS PA field-device networks. Confirm the supported functions and architecture in the product documentation.

Q2: What is the difference between EtherNet/IP and PROFIBUS PA?

EtherNet/IP uses standard Ethernet technology with the Common Industrial Protocol (CIP) for industrial communication. PROFIBUS PA is a fieldbus technology commonly used to connect process instruments. A compatible gateway helps bridge the two communication environments.

Q3: Does the 1788-EN2PAR support redundant communication?

The model is identified as a redundant gateway, but the exact redundancy architecture, supported operating modes, and required external components should be confirmed from the product's technical documentation. Do not assume that every network path or fieldbus segment is automatically redundant.

Q4: Which controllers can communicate with this gateway?

Controller compatibility depends on the supported EtherNet/IP implementation, firmware, configuration, and system architecture. Confirm compatibility with the specific Allen Bradley controller and engineering software used in the installation.

Q5: Can it connect directly to PROFIBUS PA instruments?

It is intended for PROFIBUS PA integration, but the fieldbus segment must follow the gateway's interface requirements. Verify segment power, wiring, termination, device addressing, and any required couplers or accessories before connecting instruments.

Q6: What configuration is required before commissioning?

The setup may involve configuring the EtherNet/IP connection, assigning network parameters, defining the PROFIBUS PA segment and devices, and mapping process data into the control system. Follow the configuration procedures for the exact hardware and software versions.

Q7: What should I check if the controller cannot communicate with the gateway?

Check power, status indicators, Ethernet cabling, IP settings, network switches, controller configuration, and communication diagnostics. Also confirm that the gateway's configuration matches the controller project and that no network addressing conflicts exist.

Q8: Why might PROFIBUS PA field devices fail to appear in the control system?

Possible causes include incorrect fieldbus wiring, segment power issues, addressing errors, configuration mismatches, unsupported device descriptions, or faults in the fieldbus segment. Review gateway diagnostics and verify each field device against the approved configuration.

Q9: What should be considered when installing the gateway in a control cabinet?

Confirm the mounting method, environmental limits, grounding and bonding requirements, wiring separation, ventilation, and access for maintenance. Follow the manufacturer's installation instructions and the site's electrical and hazardous-area standards where applicable.

Q10: What information is needed when ordering a replacement gateway?

Provide the complete model number, nameplate details, product condition requirements, required quantity, and any available hardware or firmware information. For an operating system, document the network topology and configuration before replacement so the new unit can be evaluated for compatibility.


Look forward to your comments!Comment
Latest comments
Tags:
Need Assistance? Chat with Us on WhatsApp!
Need Assistance? Click to Inquire
Back to top