ProSoft ILX34-MBS485 Modbus Serial Communication Module
ProSoft ILX34-MBS485 Modbus Serial Communication Module
0.0
Points
Brand:Allen Bradley PLC Item No.:ILX34-MBS485 Product Origin:USA Product Dimensions:56 x 12 x 75.5 mm Product Weight:0.02 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The ProSoft ILX34-MBS485 provides an efficient way to integrate RS-485 Modbus devices into Rockwell Automation control systems. Designed for CompactLogix L1 processors and distributed POINT I/O applications, it supports serial data exchange between PLCs and industrial equipment such as meters, drives, process instruments, and third-party controllers.
A key advantage of the module is its ability to support both Modbus Master and Slave configurations. This allows it to fit different communication architectures, whether the controller needs to collect data from several field devices or make information available to an external Modbus Master. Its RS-485 interface also supports longer communication distances, making it suitable for installations where connected equipment is distributed across a production area or facility.
The module integrates with RSLogix 5000 and Studio 5000 through an Add-On Instruction, providing structured data and diagnostic information for the controller application. Configuration backup within the CompactLogix project further supports maintenance and replacement procedures.
For industrial facilities upgrading existing serial networks or integrating Modbus equipment into a Logix-based system, the ILX34-MBS485 offers a compact communication interface without requiring a separate protocol gateway for the supported applications.
Technical Specifications
Parameter
Specification
Brand
ProSoft Technology
Model
ILX34-MBS485
Product Type
Modbus RS-485 Serial Communication Module
Compatible Platform
CompactLogix L1 / POINT I/O Adapter Systems
Serial Interface
RS-485
Communication Protocol
Modbus
Operating Modes
Modbus Master / Modbus Slave
Modbus Formats
RTU / ASCII
Baud Rates
2,400 / 4,800 / 9,600 / 19,200 / 38,400 bps
Data Size
7 or 8 bits
Stop Bits
1 or 2
Parity
None / Even / Odd
Node Address
1–247
Maximum Data Capacity
Up to 1,000 words
Maximum Modbus Commands
30
Maximum Words per Command
36
Configuration Software
RSLogix 5000 / Studio 5000
Power Supply
10–28.8 VDC
POINTBus Current
75 mA at 5 VDC
Serial Line Voltage
-7 to +12 VDC
Communication Distance
Up to 4,000 ft (1,219 m), application-dependent
Module Installation
Compatible POINT I/O wiring base
Status Indicators
Module Status, Network Status, TXD, RXD
Operating Temperature
0 to +55°C
Storage Temperature
0 to +55°C
Relative Humidity
5–95% RH, non-condensing
Dimensions
56 x 12 x 75.5 mm
Weight
0.02 kg / 0.04 lb
Recommended Related Models
Model
Product Type
ILX34-MBS232
Modbus RS-232 Serial Communication Module
ILX56-PBM
PROFIBUS DP Master/Slave Communication Module
ILX56-PBS
PROFIBUS DP Slave Communication Module
1734-AENTR
POINT I/O Dual-Port EtherNet/IP Adapter
1734-TB
POINT I/O Terminal Base
Popular Related Models
Model
Product Type
1769-L16ER-BB1B
CompactLogix 5370 L1 Controller
1769-L18ER-BB1B
CompactLogix 5370 L1 Controller
1734-AENT
POINT I/O EtherNet/IP Adapter
1734-AENTR
POINT I/O Dual-Port EtherNet/IP Adapter
1734-IB8
POINT I/O 8-Point Digital Input Module
1734-OB8
POINT I/O 8-Point Digital Output Module
1734-IE2C
POINT I/O 2-Channel Analog Input Module
1734-OE2C
POINT I/O 2-Channel Analog Output Module
Applications
The ILX34-MBS485 is suitable for industrial systems that need to connect multiple serial devices to a CompactLogix L1 controller or POINT I/O architecture.
SCADA Systems: Connects Modbus-compatible field equipment to PLC-based supervisory systems for centralized monitoring and data acquisition.
Distributed Instrumentation: Communicates with meters, transmitters, analyzers, and other process instruments across RS-485 networks.
Industrial Equipment Integration: Links PLC systems with drives, controllers, and other Modbus-enabled equipment for data exchange and operational coordination.
Building and Utility Automation: Supports serial communication with monitoring and control devices used in energy management and utility applications.
Legacy System Upgrades: Integrates existing Modbus serial equipment into newer Rockwell Automation control architectures without replacing every field device.
Remote Field Device Communication: Uses the extended transmission range of RS-485 to connect equipment located farther from the controller than typical RS-232 links allow.
Advantages and Key Features
RS-485 Serial Communication
The ILX34-MBS485 provides an RS-485 interface for industrial Modbus communication. Its differential signaling is suitable for multi-device networks and helps maintain communication reliability in electrically noisy industrial environments.
Extended Communication Distance
The module is designed to connect devices located up to 4,000 feet (1,219 meters) from the processor under appropriate installation conditions. This makes it useful for distributed equipment and larger machine or process installations.
Modbus Master and Slave Modes
The serial port can be configured as either a Modbus Master or Slave. In Master mode, the module initiates requests to connected devices. In Slave mode, it responds to requests from an external Modbus Master.
Support for Modbus RTU and ASCII
The module supports both Modbus RTU and ASCII communication formats. RTU uses CRC-16 error checking, while ASCII uses LRC error checking, providing compatibility with a broad range of serial Modbus equipment.
Flexible Data Handling
The ILX34-MBS485 supports up to 1,000 words of data and up to 30 Modbus commands, with up to 36 words per command. This allows users to organize register and coil exchanges around the requirements of their application.
Logix Controller Integration
Configuration is performed through RSLogix 5000 or Studio 5000. The associated Add-On Instruction provides structured access to I/O, status, and control data, reducing the need to develop communication handling from scratch.
Diagnostic Information
Communication and module status information is available through controller tags. Dedicated TXD and RXD indicators provide a quick visual reference for serial activity, helping maintenance personnel investigate communication problems.
Project-Based Configuration Backup
Module configuration can be backed up within the CompactLogix project file. This helps preserve communication settings as part of the control system project and supports maintenance and system restoration.
Technical FAQs
Q1: What is the primary function of the ILX34-MBS485?
A: The ILX34-MBS485 provides an RS-485 serial interface for Modbus communication between CompactLogix L1 or compatible POINT I/O systems and external Modbus devices.
Q2: Can the module communicate with multiple Modbus devices?
A: Yes. Its RS-485 interface supports multi-device communication networks. The actual number of connected devices depends on network electrical characteristics, device loading, wiring, and the selected communication configuration.
Q3: Does the ILX34-MBS485 support both Modbus Master and Slave modes?
A: Yes. It can be configured as a Modbus Master to initiate requests or as a Modbus Slave to respond to requests from another Modbus Master.
Q4: Which Modbus communication formats are supported?
A: The module supports Modbus RTU and Modbus ASCII. RTU uses CRC-16 error checking and requires an 8-bit data size, while ASCII uses LRC error checking.
Q5: Which baud rates are supported?
A: The published specifications list 2,400, 4,800, 9,600, 19,200, and 38,400 bps. The baud rate and other serial parameters must match the settings of the connected Modbus devices.
Q6: How many Modbus commands can be configured?
A: The module supports up to 30 Modbus commands and up to 36 words per command. The total supported data capacity is up to 1,000 words.
Q7: Which Modbus function codes are supported?
A: Supported function codes include reading coils, discrete inputs, holding registers, and input registers, as well as writing single or multiple coils and registers. Function code 8 is supported for the specified Slave diagnostic subfunction.
Q8: How is the module configured in a CompactLogix system?
A: Configuration is performed using RSLogix 5000 or Studio 5000 and the associated Add-On Instruction. Users configure the communication role, serial parameters, Modbus node addresses, and data exchange commands according to the application.
Q9: What should be checked if the module cannot communicate with a field device?
A: Check the RS-485 wiring polarity, network termination, baud rate, parity, stop bits, data size, and Modbus node address. Also inspect the TXD and RXD indicators and review diagnostic information in the controller tags.
Q10: Which wiring base is required for installation?
A: The ILX34-MBS485 requires a compatible POINT I/O wiring base, such as the 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS. The wiring base is a separate component and is not included with the communication module.