Brand:Siemens Item No.:6AG2193-6AR00-4AA0 Product Origin:Germany Product Dimensions:20 × 69.5 × 59 mm Product Weight:0.058 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Siemens 6AG2193-6AR00-4AA0 is a specialized BusAdapter for the SIMATIC ET 200SP distributed I/O system. It provides two RJ45 Ethernet ports for PROFINET communication and uses an integrated switch to support network connections between compatible automation devices.
As a SIPLUS extreme RAIL product, it is designed for applications where environmental conditions require additional protection beyond that offered by standard ET 200SP accessories. Its conformal coating improves resistance to environmental contaminants, while its extended temperature capability supports installations operating under wider temperature variations.
The adapter is particularly relevant to railway automation, transportation infrastructure, and industrial control systems that use distributed ET 200SP stations. By providing the physical Ethernet interface for compatible PROFINET interface modules, it helps connect remote I/O stations to central PLC controllers and industrial networks.
For system integrators and maintenance teams, the 6AG2193-6AR00-4AA0 offers a compact network connection solution within the ET 200SP platform. Correct selection of the interface module, cable type, network topology, and installation conditions is important for reliable operation.
Technical Specifications
Parameter
Specification
Brand
Siemens
Model
6AG2193-6AR00-4AA0
Product Type
SIPLUS ET 200SP BA 2xRJ45 TX RAIL BusAdapter
Base Model
6ES7193-6AR00-0AA0
Product Designation
BA 2xRJ45
System
SIMATIC ET 200SP
Communication Protocol
PROFINET IO
Number of PROFINET Interfaces
1
Number of RJ45 Ports
2
Integrated Switch
Yes
Transmission Medium
Copper Ethernet
Maximum Cable Length
100 m general specification; 50 m in railway-specific selection data
Environmental Protection
Conformal coating
Railway Application
SIPLUS extreme RAIL
Operating Temperature
-40 to +70°C
Short-Term Temperature
+85°C for 10 minutes under specified conditions
Compatible Interface Modules
ET 200SP PROFINET interface modules, standard function class or higher
Dimensions
20 × 69.5 × 59 mm
Weight
0.058 kg / 0.13 lb
Recommended Related Models
Model
Product Type
6ES7193-6AR00-0AA0
ET 200SP BA 2xRJ45 BusAdapter
6AG1193-6AR00-7AA0
SIPLUS ET 200SP BA 2xRJ45 BusAdapter
6AG2193-6AF00-4AA0
SIPLUS ET 200SP BA 2xFC TX RAIL BusAdapter
6AG2193-6AM00-4AA0
SIPLUS ET 200SP BA 2xM12 RAIL BusAdapter
6ES7155-6AU01-0BN0
ET 200SP PROFINET Interface Module
Popular Related Models
Model
Product Type
6ES7155-6AU00-0CN0
ET 200SP PROFINET Interface Module
6ES7155-6AU01-0BN0
ET 200SP PROFINET Interface Module
6ES7131-6BH01-0BA0
ET 200SP Digital Input Module
6ES7132-6BH01-0BA0
ET 200SP Digital Output Module
6ES7134-6GD01-0BA1
ET 200SP Analog Input Module
6ES7135-6HD00-0BA1
ET 200SP Analog Output Module
6ES7193-6BP00-0BA0
ET 200SP BaseUnit
6ES7193-6BP20-0BA0
ET 200SP BaseUnit
Applications
PROFINET Network Connectivity: Provides Ethernet connections between ET 200SP stations and industrial PROFINET networks.
Railway Automation: Supports communication in railway control and monitoring installations requiring enhanced environmental protection.
Distributed I/O Systems: Connects compatible ET 200SP interface modules to PROFINET controllers and network infrastructure.
Industrial Machine Automation: Enables network communication between distributed I/O stations and central PLC systems.
Production Line Networking: Supports communication links between automation stations in manufacturing environments.
Harsh Industrial Installations: Offers additional protection for applications exposed to temperature variations, dust, moisture, and chemically active substances.
Advantages and Key Features
Two RJ45 Ethernet Ports
The BusAdapter provides two RJ45 sockets for PROFINET communication. This allows flexible network cabling and supports connection arrangements using the integrated switch.
Integrated PROFINET Switch
The two ports belong to one PROFINET interface with an integrated switch. This helps simplify Ethernet connections between compatible ET 200SP stations and reduces the need for separate switching hardware in suitable network layouts.
SIPLUS Conformal Coating
The circuit board assembly features conformal coating designed to improve resistance to environmental contaminants. This is particularly valuable in railway and industrial applications where conventional electronic components may be exposed to more demanding conditions.
Extended Temperature Capability
The specified operating temperature range is -40 to +70°C, with +85°C permitted for 10 minutes under the specified OT4 and ST1/ST2 conditions. This makes the adapter suitable for installations with wider temperature variations.
Railway Application Design
The product is part of the SIPLUS extreme RAIL portfolio and supports railway-related environmental and EMC requirements. It is designed for use with compatible PROFINET interface modules in standard function class or higher.
Reliable Copper Ethernet Connection
The RJ45 interfaces support copper Ethernet cabling with a maximum cable length of 100 m under standard technical conditions. For the railway-specific product configuration, Siemens specifies a maximum cable length of 50 m in its selection data.
ET 200SP System Integration
The adapter is designed for compatible ET 200SP interface modules. It provides the physical Ethernet connection required for communication between the distributed I/O station and the PROFINET network.
Compact Modular Design
Its compact form factor supports installation in space-conscious ET 200SP configurations while keeping network connections accessible for commissioning and maintenance.
Technical FAQs
Q1: What is the main function of the Siemens 6AG2193-6AR00-4AA0?
A: It is a SIPLUS ET 200SP BA 2xRJ45 TX RAIL BusAdapter. Its primary function is to provide two RJ45 connections for PROFINET communication with compatible ET 200SP interface modules.
Q2: How many Ethernet ports does this BusAdapter have?
A: It has two RJ45 ports connected through an integrated switch. Both ports belong to one PROFINET interface.
Q3: Is the 6AG2193-6AR00-4AA0 a PROFINET communication module?
A: It is a BusAdapter rather than an independent communication processor. It provides the physical RJ45 network connections for a compatible ET 200SP interface module.
Q4: Which standard Siemens model is this product based on?
A: It is based on the standard 6ES7193-6AR00-0AA0 BA 2xRJ45 BusAdapter, with SIPLUS extreme RAIL environmental protection.
Q5: What is the maximum Ethernet cable length?
A: Siemens lists a maximum copper cable length of 100 m in the general technical data. The railway-specific selection information specifies a maximum cable length of 50 m. The applicable limit should be selected according to the installation requirements and product documentation.
Q6: What is the operating temperature range?
A: The specified range is -40 to +70°C, with +85°C permitted for 10 minutes under the applicable OT4 and ST1/ST2 conditions. Installation orientation and environmental requirements should also be considered.
Q7: What does the SIPLUS conformal coating provide?
A: It provides additional protection for the electronic assembly against environmental influences, including chemically and mechanically active substances. This helps improve suitability for demanding industrial and railway environments.
Q8: Can the BusAdapter be used with any ET 200SP interface module?
A: It is intended for compatible ET 200SP PROFINET interface modules in standard function class or higher. The exact interface module and BusAdapter compatibility should be checked before installation.
Q9: Can the two RJ45 ports be used for network line connections?
A: Yes. The integrated switch supports network connection arrangements using both ports. The actual topology must comply with the supported PROFINET configuration and network design.
Q10: What should be checked if the PROFINET connection is unavailable?
A: Check the RJ45 cable connections, connector condition, network configuration, interface module compatibility, and PROFINET device status. Also verify that unused interfaces remain protected with the supplied plug covers during operation.