Allen Bradley PLC

  1. Home
  2. Products
  3. Allen Bradley PLC
  4. Allen Bradley 440R-W23224 Guardmaster Safety Relays
Allen Bradley 440R-W23224 Guardmaster Safety Relays

Allen Bradley 440R-W23224 Guardmaster Safety Relays

0.0
Points

Brand:Allen Bradley PLC
Item No.:440R-W23224
Product Origin:USA
Product Dimensions:114.5 x 22.5 x 99 mm
Product Weight:0.2 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

Introduction

The Allen Bradley 440R-W23224 Guardmaster MSR338P Group 1 Time Delay Expansion Module is designed to extend the output functions of compatible MSR300 modular safety relay systems. It provides three delayed normally open safety outputs and one delayed normally closed auxiliary output, making it suitable for machine applications that require a controlled delay before selected circuits change state.

Unlike the MSR330P standard output modules, the MSR338P is intended for time-delay safety applications. Its Group 1 designation identifies its position in the modular output arrangement, so correct group selection is essential when maintaining or expanding an existing installation.

The module receives its 24V DC supply from the base unit and uses removable terminal connections. Rockwell Automation has discontinued this model, effective February 28, 2022. It remains relevant to maintenance teams and spare-parts buyers supporting existing MSR300 installations.

Technical Specifications

Parameter

Specification

Brand

Allen Bradley

Product Family

Guardmaster MSR300

Model

440R-W23224

Product Type

MSR338P Time Delay Expansion Module

Group Number

Group 1

Safety Outputs

3 delayed normally open (N.O.)

Auxiliary Outputs

1 delayed normally closed (N.C.)

Input Channels

None

Power Supply

24V DC from base unit

Terminal Type

Removable

Mounting

DIN Rail

Safety Performance

SIL 3 / PLe, subject to system design and applicable conditions

Lifecycle Status

Discontinued

Dimensions

114.5 × 22.5 × 99 mm

Weight

0.20 kg / 0.44 lb

Recommended Related Models

Model

Product Description

440R-W23224

Guardmaster MSR338P Group 1 Time Delay Expansion Module

440R-W23225

Guardmaster MSR338P Group 2 Time Delay Expansion Module

440R-W23226

Guardmaster MSR338P Group 3 Time Delay Expansion Module

440R-W23221

Guardmaster MSR330P Group 1 Safety Output Module

440R-W23222

Guardmaster MSR330P Group 2 Safety Output Module

440R-W23223

Guardmaster MSR330P Group 3 Safety Output Module

Popular Related Models

Model

Product Description

440R-W23217

Guardmaster MSR329P Muting Lamp Module

440R-W23218

Guardmaster MSR320P Safety Relay Module

440R-W23219

Guardmaster MSR310P Safety Relay Module

440R-W23220

Guardmaster MSR312P Safety Relay Module

440R-EM4R2

Guardmaster GSR Expansion Module

440C-CR30-22BBB

Guardmaster Configurable Safety Relay

Replacement note: The 440R-W23224 is a Group 1 time-delay output module. The Group 2 and Group 3 versions have different catalog numbers. Confirm the required output group, base-unit compatibility, and safety-system configuration before purchasing or installing a replacement.


Applications

The Allen Bradley 440R-W23224 is a Guardmaster MSR338P Group 1 module designed for use in compatible MSR300 modular safety relay systems. It belongs to the MSR338P time-delay output module family, which supports safety applications where controlled or delayed switching of designated output circuits is required.

Typical application areas include:

  • Industrial machinery: Supports safety-related output control in machinery requiring coordinated stopping sequences.

  • Automated production lines: Helps manage designated safety output groups in multi-zone installations.

  • Conveyor systems: Can be incorporated into safety arrangements where controlled shutdown timing is part of the machine design.

  • Robotic work cells: Supports compatible safety architectures that require time-delayed output functions.

  • Machine guarding: Forms part of a modular safety system for equipment with multiple protective devices and output groups.


Advantages

Time-Delay Output Function

The MSR338P family is designed for safety applications requiring time-delayed output operation. This can support controlled machine shutdown sequences when properly configured.

Group 1 Configuration

The Group 1 designation identifies the module's position within the MSR300 output architecture. Correct group selection is important when replacing or expanding an existing system.

Modular Integration

The module is intended to work with compatible MSR300 components, allowing safety functions to be organized across multiple output groups.

Industrial Control Application

Its role in a machine safety system makes it relevant to industrial maintenance, spare-parts replacement, and control panel restoration.

Compact Module Format

The narrow module profile helps accommodate modular safety components in industrial control cabinets.


Technical FAQs

Q1: What is the Allen Bradley 440R-W23224?

It is a Guardmaster MSR338P Group 1 module belonging to the MSR300 modular safety relay family.

Q2: What is the difference between the MSR338P and MSR330P families?

The MSR338P family is associated with time-delay output functionality, while the MSR330P models provide standard safety output functions. Confirm the exact system requirements before selecting either type.

Q3: What does Group 1 indicate?

Group 1 identifies the designated output group for this module within the compatible modular safety arrangement.

Q4: Is the 440R-W23224 a standalone safety relay?

It should be treated as a modular system component rather than an independent safety input-monitoring relay. It requires the appropriate compatible MSR300 configuration.

Q5: Can this module be used for controlled machine shutdown?

It may be used in a compatible safety design where time-delayed output operation is required. The overall stopping sequence must be engineered and validated for the specific machine.

Q6: Does the module monitor emergency-stop devices directly?

The 440R-W23224 is an output module. Emergency-stop and other safety input signals must be handled by the appropriate input-monitoring components in the system.

Q7: What should be checked before installing the module?

Verify the complete catalog number, output group, base-module compatibility, wiring arrangement, and the safety-system documentation.

Q8: Can the 440R-W23224 replace a 440R-W23221?

Not automatically. These models belong to different MSR300 module configurations. Their output functions and intended applications must be checked before considering a replacement.

Q9: Is the 440R-W23224 suitable for existing MSR300 installations?

It may be suitable where the original system documentation specifies this module and the associated components remain compatible. Confirm the complete configuration before installation.

Q10: What should be considered when sourcing this model?

Check the exact catalog number and product condition, and confirm that the module matches the required Group 1 time-delay output configuration.


Look forward to your comments!Comment