Honeywell DCS

  1. Home
  2. Products
  3. Honeywell DCS
  4. Honeywell FS-TIDI-1624 Safe Digital Input Module
Honeywell FS-TIDI-1624 Safe Digital Input Module

Honeywell FS-TIDI-1624 Safe Digital Input Module

0.0
Points

Brand:Honeywell DCS
Item No.:FS-TIDI-1624
Product Origin:USA
Product Dimensions:265 × 70 × 48 mm
Product Weight:0.45 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

Introduction

The Honeywell FS-TIDI-1624 Safe Digital Input Module delivers dependable digital signal acquisition within certified safety systems. Engineered for mission-critical applications, it ensures every field input is accurately detected, validated, and monitored for potential faults.

With high channel density and integrated diagnostics, the module reduces wiring complexity while enhancing operational transparency. Its compatibility with Honeywell safety platforms ensures smooth integration into both new installations and system upgrades. For operators prioritizing safety, uptime, and compliance, the FS-TIDI-1624 represents a trusted and field-proven solution.


Technical Specifications

ParameterSpecification
Product TypeSafe Digital Input Module
ModelFS-TIDI-1624
Number of Channels16 Digital Inputs
Input Type24 VDC Discrete Signals
IsolationGalvanic Isolation
Diagnostic FeaturesOpen/Short Circuit Detection
MountingRack/Chassis Mounted
System CompatibilityHoneywell Safety Systems
Dimensions265 × 70 × 48 mm
Weight0.45 kg

Recommended Related Models

ModelModule TypeCore Function
FS-TSDO-0824Safe Digital Output ModuleSafety Output Control
FS-TSAI-1620Safe Analog Input ModuleAnalog Signal Monitoring
FS-TSRO-0824Safe Relay Output ModuleRelay-Based Actuation
FS-CPUS-0001Safety CPU ModuleSafety Logic Processing
FC-TPSU-2430Power Supply ModuleSystem Power Management
FS-TDIO-0824Safe Digital I/O ModuleCombined Input/Output

Popular Related Models

ModelModule TypeApplication Focus
FSC Safety ControllerSafety ControllerProcess Safety Management
FS-SICC-0001Communication ModuleSafety Network Integration
FS-TSDI-0816Safe Digital Input ModuleCompact Safety Systems
FS-TSAI-0820Safe Analog Input ModuleProcess Measurement
FS-CHAS-4SLOTChassis ModuleModular Expansion
FC-PSU-2405Power Supply ModuleControl System Power


Applications

The Honeywell FS-TIDI-1624 Safe Digital Input Module is purpose-built for safety-critical signal acquisition in high-risk industrial environments. It is commonly deployed in:

  • Emergency Shutdown (ESD) systems

  • Burner Management Systems (BMS)

  • Fire & Gas monitoring systems

  • Turbine protection and overspeed systems

  • Process interlock control in oil & gas facilities

  • Refinery and petrochemical safety loops

  • Power generation safety instrumented systems (SIS)

  • Offshore platform control cabinets

Its deterministic response and diagnostic transparency make it ideal for applications where signal reliability directly impacts plant safety and regulatory compliance.


Advantages

  • Safety-Certified Architecture – Designed for integration within Honeywell safety systems requiring high diagnostic coverage.

  • 16-Channel Density – Optimizes panel space while maintaining channel isolation integrity.

  • Built-in Line Monitoring – Detects open circuit, short circuit, and field wiring faults.

  • High Noise Immunity – Suitable for electrically harsh industrial environments.

  • Fast Signal Processing – Ensures precise capture of state transitions in safety loops.

  • Hot-Swap Capability – Supports module replacement without interrupting system operation (depending on system configuration).

  • Redundant System Compatibility – Fully supports redundant safety controller architectures.

  • Reduced Commissioning Time – Clear LED diagnostics simplify startup and troubleshooting.


Technical FAQs

1. What type of input signals does FS-TIDI-1624 support?
It supports 24 VDC digital field input signals typically used for contact closures, proximity switches, and safety interlocks.

2. Are the input channels galvanically isolated?
Yes, the channels are isolated to ensure signal integrity and minimize cross-channel interference.

3. Does the module support line fault detection?
Yes, it continuously monitors for open circuit and short circuit conditions in field wiring.

4. What is the typical input voltage threshold for logic recognition?
The module is designed for standard industrial 24 VDC logic levels with defined ON/OFF thresholds to ensure reliable state detection.

5. Is it compatible with redundant safety controllers?
Yes, it is designed for operation in redundant safety system architectures.

6. What diagnostic feedback is available to the system controller?
Channel status, line fault status, and module health information are communicated to the controller.

7. Does the module require external signal conditioning?
No additional conditioning is typically required for standard 24 VDC discrete signals.

8. How is channel status indicated locally?
LED indicators provide real-time channel state and fault status information.

9. What type of field wiring configuration is supported?
It supports dry contact inputs, powered digital signals, and supervised loop configurations.

10. Is configuration performed locally or via software?
Configuration is performed through the associated Honeywell safety system engineering tools.


Look forward to your comments!Comment
Latest comments
Tags:
Need Assistance? Chat with Us on WhatsApp!
Need Assistance? Click to Inquire
Back to top