Honeywell DCS

  1. Home
  2. Products
  3. Honeywell DCS
  4. Honeywell TC-IXR061 96978377 A01 RTD Analog Input Module
Honeywell TC-IXR061 96978377 A01 RTD Analog Input Module

Honeywell TC-IXR061 96978377 A01 RTD Analog Input Module

0.0
Points

Brand:Honeywell DCS
Item No.:TC-IXR061
Product Origin:USA
Product Dimensions:180 x 120 x 30 mm
Product Weight:0.281 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

Introduction

The Honeywell TC-IXR061 96978377 A01 RTD Analog Input Module is a high-performance solution for industrial temperature measurement using RTD sensors. With 20 analog inputs and 6 galvanically isolated channels, it delivers reliable and accurate data while protecting signal integrity.

Built with open-wire detection and industrial-grade construction, the TC-IXR061 ensures dependable operation in critical applications such as DCS, BMS, and power generation facilities. Its compact 180 × 160 × 30 mm form factor and 0.281 kg weight make it easy to integrate into Honeywell TC system architectures.


Technical Specifications

ParameterSpecification
Product TypeRTD Analog Input Module
ModelTC-IXR061 96978377 A01
Number of Input Points20 Analog RTD Inputs
Galvanically Isolated Channels6 Channels
DiagnosticsOpen-Wire Detection
Module CompatibilityHoneywell TC Series Controllers
Mounting TypeControl Cabinet / Modular Rack
Dimensions180 × 160 × 30 mm
Weight0.281 kg

Recommended Related Models

ModelTypeCore Function
TC-IXR062RTD Analog Input ModuleExtended RTD Input Points
TC-TAIH02Analog Input ModuleHigh-Precision Analog Measurement
TC-HAO081Analog Output Module8-Channel HART Output
TC-TDIA12Digital Input ModuleSignal Monitoring
TC-CCN012Redundant Net Interface ModuleNetwork Redundancy
TC-PSU2401Power Supply Module24 VDC Cabinet Power

Popular Related Models

ModelTypeApplication Focus
TC-TAMT03Temperature Input ModuleThermal Signal Acquisition
TC-TAMR03Relay ModuleOutput Switching
TC-KLAM02Low-Level Mux CableCabinet Signal Interconnection
TC-KFTA20FTA CableField Wiring Interface
TC-CPUS001Controller ModuleSafety Logic Processing
TC-IXL061Thermocouple Input ModuleTemperature Measurement


Applications

The Honeywell TC-IXR061 96978377 A01 RTD Analog Input Module is engineered for precise temperature measurement using RTD sensors in industrial process control environments. Its 20-point analog input capacity, with 6 galvanically isolated channels, makes it suitable for:

  • Industrial process temperature monitoring and control

  • Boiler, furnace, and heat exchanger temperature acquisition

  • Turbine and generator thermal supervision

  • Power generation plant RTD input expansion

  • Chemical and petrochemical process monitoring

  • Burner Management System (BMS) thermal loops

  • Distributed Control System (DCS) multi-point temperature monitoring

  • Critical applications requiring open-wire detection and isolation

The module enables high-accuracy RTD measurements while maintaining safety and signal integrity in demanding industrial environments.


Advantages

  • 20-Point Analog Input Capacity – Supports multiple RTD sensor connections in a single module.

  • 6 Galvanically Isolated Channels – Prevents interference between critical measurement channels.

  • Open-Wire Detection – Provides automatic diagnostics for RTD wiring faults.

  • High Accuracy RTD Measurement – Ensures precise temperature acquisition across multiple zones.

  • Compact Industrial Form Factor – Fits neatly in modular control cabinets.

  • Seamless Integration – Fully compatible with Honeywell TC series controllers.

  • Reliable Operation – Designed for continuous industrial and process control environments.


Technical FAQs

1. How many RTD inputs are supported?
The module provides 20 analog input points for RTD sensors.

2. How many channels are galvanically isolated?
6 channels are galvanically isolated for enhanced signal integrity.

3. Does the module support open-wire detection?
Yes, it provides automatic open-wire fault detection.

4. What types of RTDs are compatible?
It supports standard industrial RTD sensors (e.g., Pt100).

5. Can it be used in high-demand industrial environments?
Yes, it is designed for power plants, petrochemical, and process industries.

6. How is temperature data transmitted to the controller?
RTD signals are digitized and transmitted through the TC system backplane.

7. Is the module compatible with Honeywell TC controllers?
Yes, it integrates seamlessly with TC series systems.

8. Are the isolated channels suitable for long-distance wiring?
Yes, galvanic isolation helps prevent interference over long cable runs.

9. Can multiple TC-IXR061 modules be installed in a rack?
Yes, modular design allows for scalable multi-point temperature acquisition.

10. Does it provide diagnostic information for each channel?
Yes, open-wire and wiring fault status can be monitored via the system interface.


Look forward to your comments!Comment
Latest comments
Tags:
Need Assistance? Chat with Us on WhatsApp!
Need Assistance? Click to Inquire
Back to top