Honeywell DCS

  1. Home
  2. Products
  3. Honeywell DCS
  4. Honeywell TC-IXR061 97202671 A01 RTD Analog Input Module
Honeywell TC-IXR061 97202671 A01 RTD Analog Input Module

Honeywell TC-IXR061 97202671 A01 RTD Analog Input Module

0.0
Points

Brand:Honeywell DCS
Item No.:TC-IXR061
Product Origin:USA
Product Dimensions:180 x 120 x 30 mm
Product Weight:0.281 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

Introduction

The Honeywell TC-IXR061 97202671 A01 RTD Analog Input Module provides high-performance multi-point temperature measurement for industrial control and safety systems. Featuring 20 analog input points with 6 galvanically isolated channels and built-in open-wire detection, it delivers reliable and precise temperature data for critical process monitoring.

Its compact 180 × 160 × 30 mm form factor and lightweight 0.281 kg design allow easy installation in standard Honeywell TC modular control cabinets. Engineered for continuous operation, the TC-IXR061 is ideal for DCS, BMS, and power generation applications where accurate thermal measurement is essential.


Technical Specifications

ParameterSpecification
Product TypeRTD Analog Input Module
ModelTC-IXR061 97202671 A01
Number of Input Points20 Analog RTD Inputs
Galvanically Isolated Channels6 Channels
DiagnosticsOpen-Wire Detection
Module CompatibilityHoneywell TC Series Controllers
Mounting TypeControl Cabinet / Modular Rack
Dimensions180 × 160 × 30 mm
Weight0.281 kg

Recommended Related Models

ModelTypeCore Function
TC-IXR062RTD Analog Input ModuleExtended RTD Input Points
TC-TAIH02Analog Input ModuleHigh-Precision Analog Measurement
TC-HAO081Analog Output Module8-Channel HART Output
TC-TDIA12Digital Input ModuleSignal Monitoring
TC-CCN012Redundant Net Interface ModuleNetwork Redundancy
TC-PSU2401Power Supply Module24 VDC Cabinet Power

Popular Related Models

ModelTypeApplication Focus
TC-TAMT03Temperature Input ModuleThermal Signal Acquisition
TC-TAMR03Relay ModuleOutput Switching
TC-KLAM02Low-Level Mux CableCabinet Signal Interconnection
TC-KFTA20FTA CableField Wiring Interface
TC-CPUS001Controller ModuleSafety Logic Processing
TC-IXL061Thermocouple Input ModuleTemperature Measurement


Applications

The Honeywell TC-IXR061 97202671 A01 RTD Analog Input Module is built for high-accuracy temperature monitoring in industrial and process automation systems. With 20 analog input points and 6 galvanically isolated channels, it is suitable for:

  • Multi-zone temperature monitoring in boilers, furnaces, and heat exchangers

  • Turbine and generator thermal supervision

  • Reactor vessel and process unit temperature measurement

  • Power generation plant RTD input expansion

  • Chemical and petrochemical process control

  • Burner Management System (BMS) thermal loops

  • Distributed Control System (DCS) RTD input integration

  • Applications requiring open-wire detection and channel isolation

Its combination of high input density and galvanic isolation ensures reliable, accurate, and safe temperature data acquisition.


Advantages

  • 20 Analog RTD Inputs – Enables multi-point temperature monitoring in a single module.

  • 6 Galvanically Isolated Channels – Reduces cross-channel interference and enhances signal integrity.

  • Open-Wire Detection – Automatically identifies RTD wiring faults.

  • High Accuracy Measurement – Ensures precise temperature data for critical processes.

  • Compact Industrial Design – Fits standard modular control cabinets.

  • Seamless Integration – Fully compatible with Honeywell TC series controllers.

  • Robust and Reliable – Designed for continuous operation in industrial environments.


Technical FAQs

1. How many RTD input points does the module provide?
It provides 20 analog RTD input points.

2. How many channels are galvanically isolated?
6 channels are galvanically isolated to prevent interference.

3. Does it support open-wire detection?
Yes, the module provides automatic detection of open or disconnected RTD wires.

4. What types of RTDs are supported?
Standard industrial RTDs, such as Pt100, are supported.

5. Can the module be used in harsh industrial environments?
Yes, it is suitable for power plants, petrochemical, and heavy industrial processes.

6. How is temperature data transmitted to the controller?
Signals are digitized and communicated via the TC system backplane.

7. Is the module compatible with Honeywell TC controllers?
Yes, it integrates seamlessly within TC-based DCS and safety architectures.

8. Are the isolated channels suitable for long cable runs?
Yes, galvanic isolation ensures reliable measurements over long wiring distances.

9. Can multiple modules be installed in a single rack?
Yes, the modular design supports scalable multi-point temperature acquisition.

10. Does it provide diagnostic information for each channel?
Yes, open-wire faults and channel status can be monitored via the system interface.


Look forward to your comments!Comment
Latest comments
Tags:
Need Assistance? Chat with Us on WhatsApp!
Need Assistance? Click to Inquire
Back to top