Schneider Electric 140DII33000C Modicon Quantum Intrinsically Safe Current Input Module

Schneider Electric 140DII33000C Modicon Quantum Intrinsically Safe Current Input Module

0.0
Points

Brand:Schneider PLC
Item No.:Schneider 140DII33000C
Product Origin: USA
Product Dimensions:155 × 110 × 45 mm
Product Weight:0.30 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

140DII33000C140DII33000C140DII33000C140DII33000C

The Schneider Electric 140DII33000C is an intrinsically safe discrete current input module engineered for the Modicon Quantum PLC automation platform. This specialty I/O module provides 8 intrinsically safe input channels designed to interface with field signals in hazardous areas (explosive atmospheres) when used with certified intrinsic safety barriers. It is ideal for industrial installations requiring safe signal acquisition while minimizing the risk of ignition in classified environments.


Technical Specifications

SpecificationDetails
Product TypeIntrinsically Safe Current Input Module
PlatformModicon Quantum PLC
Number of Input Channels8 discrete current inputs
Input Characteristics1.2 mA … 2.1 mA switching thresholds (typical)
Intrinsic SafetyDesigned for hazardous area use (requires certified IS barriers)
Switching Frequency~100 Hz
Internal Resistance~2.5 kΩ (approximate)
Response Time~1 ms (resistive)
Operating Temperature0 °C to 60 °C
Storage Temperature–40 °C to 85 °C
HumidityUp to 95 % non‑condensing (typical industrial standard)
Bus Current Requirement~330 mA (typical for Quantum I/O modules)
MountingStandard Modicon Quantum backplane
Dimensions (H × W × D)~155 × 110 × 45 mm (standard Quantum I/O module form factor)
Weight~0.30 kg (approx.)
StatusDiscontinued; legacy support available
End of Service DateModule discontinued; support programs continue through legacy service timelines

Physical module format conforms to Quantum I/O standard sizes and integrates seamlessly into existing local I/O racks.


Recommended Related Models

  • 140DDI36400C – 96‑point discrete input module
  • 140DAI55300C – AC discrete input module
  • 140DIO33000C – Intrinsically safe DC output module
  • 140CPU31110C – Modicon Quantum CPU
  • 140XBP01600 – Quantum backplane rack

Popular Schneider Electric PLC Modules

  • 140DAO84010C – AC discrete output module
  • 140AVI03000C – Analog input module
  • 140ADO02000C – Analog output module
  • 140DDI35300C – Low‑voltage discrete input module
  • 140DDO35300C – Low‑voltage discrete output module 


Application Scenarios

The 140DII33000C is especially suited for systems where intrinsic safety and reliable signal monitoring are required:

  • Hazardous area monitoring and control (chemical, petrochemical)
  • Material handling with risk of explosive dust or gases
  • Compressor and pump skid safety wiring
  • Process automation where safe signal acquisition from field devices is mandatory
  • Integration with Quantum PLCs in legacy installations requiring IS I/O support


Key Advantages

  • Intrinsic Safety Designed: Engineered to limit energy to safe levels for use with certified safety barriers, reducing ignition risk in classified zones.
  • 8 Discrete Inputs: Provides compact yet flexible input capacity for hazardous area signal acquisition.
  • Fast Response: Approximate 1 ms switching response supports timely detection of field signal changes.
  • Standard Modicon Integration: Fits the established Quantum I/O architecture, simplifying upgrades or expansions.
  • Industrial Ready: Designed for typical industrial ambient ranges and robust rack‑mounted installation. 


Technical FAQs

  1. What is the 140DII33000C module’s main function?
    It is an intrinsically safe current input module for monitoring discrete field signals in hazardous environments when used with proper barriers.
  2. How many input channels does it have?
    It supports 8 discrete IS current inputs.
  3. What makes a module “intrinsically safe”?
    Intrinsic safety limits electrical energy to prevent sparks or thermal effects that could ignite explosive atmospheres.
  4. What are typical switching thresholds?
    Typical input switching occurs between 1.2 mA and 2.1 mA.
  5. Is this module still manufactured?
    No — it has been discontinued; legacy support and spare parts are generally available through service channels.
  6. What environments is it designed for?
    Designed for industrial indoor environments and clean hazardous areas with appropriate IS barriers.
  7. What are its physical dimensions?
    Approximately 155 × 110 × 45 mm.
  8. How heavy is the module?
    Around 0.30 kg.
  9. What temperature range can it operate in?
    From 0 °C to 60 °C.
  10. Which PLC platform is it compatible with?
    It is designed for the Modicon Quantum automation platform.