Allen Bradley 9701-VWMR075AENE FactoryTalk View ME Station Runtime 75 Display Electronics
Allen Bradley 9701-VWMR075AENE FactoryTalk View ME Station Runtime 75 Display Electronics
0.0
Points
Brand:Allen Bradley PLC Item No.:9701-VWMR075AENE Product Origin:USA Product Dimensions:110 x 25 x 90 mm Product Weight:0.14 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Allen-Bradley 9701-VWMR075AENE FactoryTalk View ME Station Runtime is a machine-level HMI runtime license designed for executing FactoryTalk View Machine Edition applications. It enables operators to interact with industrial automation systems through preconfigured graphical interfaces, providing real-time visualization and control capabilities. As part of the Rockwell Automation FactoryTalk ecosystem, it is widely used in OEM machinery and manufacturing environments where stable and deterministic HMI runtime performance is required.
Technical Specifications
Parameter
Specification
Product Model
9701-VWMR075AENE
Software Type
FactoryTalk View Machine Edition Runtime
License Type
ME Station Runtime
Display Capacity
75 displays
Platform
Windows-based industrial PC / station
Runtime File Type
.MER applications
Communication
Ethernet / OPC / Rockwell drivers
System Integration
Allen-Bradley PLC systems
Memory Usage
System dependent
Operating System
Windows (industrial supported versions)
Installation Type
Electronic Software Delivery (ESD)
Application Scope
Single-station HMI runtime
Dimensions
110 × 25 × 90 mm (packaged)
Weight
0.14 kg
Recommended Related Models
Model
Product Name
9701-VWSTNMT31
FactoryTalk View ME Station Runtime 25 Displays License
9701-VWSTNMT32
FactoryTalk View ME Station Runtime 75 Displays Perpetual License
9701-VWMR050AENE
FactoryTalk View ME Station Runtime 50 Displays License
9701-VWMR100AENE
FactoryTalk View ME Station Runtime 100 Displays License
Popular Related Models
Model
Product Name
9701-VWMR025AENE
FactoryTalk View ME Station Runtime 25 Displays
9701-VWMR050AENE
FactoryTalk View ME Station Runtime 50 Displays
9701-VWMR150AENE
FactoryTalk View ME Station Runtime 150 Displays
9701-VWMR200AENE
FactoryTalk View ME Station Runtime 200 Displays
Applications
• Machine-level HMI runtime execution in industrial control systems
Used to run FactoryTalk View Machine Edition applications on industrial PCs or supported PanelView platforms for real-time machine monitoring and control.
• OEM machine visualization and operator interface deployment
Enables standardized HMI runtime environments for packaged machinery, ensuring consistent operator interaction across multiple machines.
• PLC-based automation system visualization
Provides runtime visualization for ControlLogix, CompactLogix, SLC 500, and PLC-5 systems through graphical operator screens.
• Manufacturing line monitoring and control stations
Supports real-time display of process variables, alarms, trends, and machine status in production environments.
• SCADA local client / station-level HMI execution
Acts as a single-station runtime node within distributed FactoryTalk View architectures.
• Legacy HMI system support and upgrade projects
Commonly used in existing installed bases where ME Station runtime licenses are still deployed for long-term operation.
Key Advantages
• Stable FactoryTalk View ME runtime environment
Ensures reliable execution of pre-built .MER applications in industrial environments.
• Supports up to 75 display objects
Allows medium-complexity HMI applications with multiple screens for operator navigation.
• Seamless integration with Rockwell Automation ecosystem
Works efficiently with Allen-Bradley PLC platforms and FactoryTalk communication services.
• PC-based or industrial station flexibility
Can be deployed on compatible Windows-based industrial computers or runtime stations.
• Optimized for machine-level performance
Designed for deterministic HMI response in real-time control applications.
• Proven installed base reliability
Widely used in long-term industrial deployments due to stable runtime performance.
Technical FAQs
Q1: What is the main function of 9701-VWMR075AENE?
A1: It is a FactoryTalk View ME Station runtime license used to run HMI applications with up to 75 displays.
Q2: Does it include development software?
A2: No, it only provides runtime capability; development requires FactoryTalk View Studio ME.
Q3: What file type does it run?
A3: It runs .MER (compiled Machine Edition runtime files).
Q4: Can it run on a PC?
A4: Yes, it can run on supported Windows-based industrial PCs.
Q5: Is it tied to specific hardware?
A5: It is licensed for a station/runtime environment rather than a specific PLC.
Q6: What does “75 displays” mean?
A6: It refers to the maximum number of display screens allowed in the runtime application.
Q7: Is this product still actively sold?
A7: It is a legacy licensing product but still available through industrial automation channels.
Q8: Can it connect to multiple PLCs?
A8: Yes, depending on application configuration, it can communicate with multiple controllers.
Q9: What software environment does it require?
A9: FactoryTalk View ME runtime environment on Windows OS.
Q10: What industries use this runtime?
A10: Manufacturing, OEM machinery, packaging, and general industrial automation.