Honeywell 2108N5000N Infrared Gas Detector

Honeywell 2108N5000N Infrared Gas Detector

0.0
Points

Brand:Honeywell DCS
Item No.:2108N5000N
Product Origin:USA
Product Dimensions:380 × 85 × 250 mm
Product Weight:1.6 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart


Introduction

The Honeywell 2108N5000N Infrared Gas Detector is designed for fixed gas monitoring in industrial environments where continuous atmospheric surveillance is required. In facilities handling combustible or hazardous gases, reliable gas detection can provide an important early warning when abnormal process conditions or leaks develop.

The detector's infrared sensing technology works by analyzing the absorption characteristics of the target gas. This provides an optical detection method that differs from catalytic and electrochemical sensing technologies.

A fixed detector is only as effective as its overall installation. Detector location should be selected based on the actual behavior of the target gas and the physical characteristics of the monitored area. Potential leak sources, ventilation patterns, airflow, gas density, temperature, and obstructions should all be considered.

In a complete industrial installation, the 2108N5000N may form part of a larger gas detection architecture. Field detection equipment can communicate gas concentration or alarm information to centralized control equipment, where appropriate responses can be initiated according to the facility's safety philosophy.

For maintenance personnel, replacing the detector requires careful attention to the complete installation rather than simply matching the enclosure. The model number, gas configuration, electrical interface, mounting arrangement, and receiving system should be checked before installation.

After replacement, commissioning should include a functional check of the detector and the associated alarm path. This confirms that the field instrument is correctly integrated into the plant's gas detection strategy.


Technical Specifications

ParameterSpecification
BrandHoneywell
Model2108N5000N
Product TypeInfrared Gas Detector
Detection TechnologyInfrared
ApplicationFixed Industrial Gas Monitoring
Primary FunctionContinuous Gas Detection
Installation TypeFixed-Point Installation
Typical EnvironmentIndustrial Process and Hazardous Areas
System IntegrationGas Detection and Alarm Systems
Dimensions380 × 85 × 250 mm
Weight1.60 kg (3.53 lb)

The Honeywell 2108N5000N has specified dimensions of 380 × 85 × 250 mm and weighs 1.60 kg (3.53 lb).

The installation area should provide sufficient access for inspection, cleaning, testing, and maintenance. The detector should also be positioned according to the properties of the target gas and the site's gas detection design.


Recommended Related Models

ModelProduct TypeTypical Application
Honeywell Searchpoint Optima PlusInfrared Gas DetectorFixed combustible gas monitoring
Honeywell Searchline ExcelOpen-Path Gas DetectorArea gas detection
Honeywell Sensepoint XCDFixed Gas DetectorIndustrial process monitoring
Honeywell Sensepoint PlusPoint Gas DetectorFixed gas detection
Honeywell Touchpoint PlusGas Detection ControllerCentralized gas monitoring

These products cover point, infrared, open-path, and centralized gas-monitoring applications. Selection should be based on target gas, sensing method, environmental conditions, hazardous-area classification, and system architecture.


Popular Related Models

ModelProduct TypeTypical Use
Honeywell Searchpoint Optima PlusInfrared Gas DetectorFixed industrial gas monitoring
Honeywell Searchline ExcelOpen-Path Gas DetectorLong-distance gas detection
Honeywell Sensepoint XCDFixed Gas DetectorProcess-area monitoring
Honeywell Sensepoint PlusPoint Gas DetectorIndustrial gas detection
Honeywell Touchpoint PlusGas Detection ControllerGas alarm and monitoring systems

For replacement projects, the complete 2108N5000N model designation should be checked against the existing system before installation. Target gas, sensing configuration, electrical interface, alarm requirements, environmental conditions, and receiving-system compatibility should all be confirmed to ensure dependable operation.


Applications

The Honeywell 2108N5000N Infrared Gas Detector is a fixed gas-monitoring instrument designed for industrial environments where continuous detection of hazardous gas conditions is required. It can be incorporated into a plant-wide gas detection strategy to monitor areas where gas releases may occur around process equipment or operating systems.

Typical applications include:

  • Oil and gas production facilities
  • Refineries
  • Petrochemical processing plants
  • Chemical manufacturing facilities
  • Gas treatment and compression stations
  • Storage and transfer areas
  • Power-generation facilities
  • Industrial process units
  • Compressor and pumping installations
  • Fixed gas detection networks

The detector is intended to operate as part of a broader gas detection arrangement rather than as a standalone safety solution. Correct placement, electrical integration, alarm logic, and regular functional testing are all important to overall system performance.


Advantages

The 2108N5000N brings infrared sensing technology into a fixed industrial gas detection format. For facilities that require continuous monitoring, its design offers a practical way to maintain gas detection coverage at selected locations.

Infrared Detection Technology
The detector uses optical absorption characteristics associated with the target gas to determine changes in the monitored atmosphere.

Continuous Fixed Monitoring
Once correctly installed, the detector can continuously monitor its assigned area without requiring an operator to perform routine manual measurements.

Industrial Process Compatibility
Fixed gas detectors can be positioned near potential release sources such as valves, flanges, compressors, pumps, pipelines, and storage equipment.

Supports Plant Safety Architecture
Gas detection signals can be incorporated into suitable alarm, control, ventilation, or emergency-response systems.

Useful for Condition Awareness
Continuous gas monitoring gives operators and safety personnel an additional source of real-time information about atmospheric conditions.

Serviceable Physical Format
The detector measures 380 × 85 × 250 mm and weighs 1.60 kg (3.53 lb), providing a manageable form factor for fixed instrumentation applications.



Technical FAQs

1. What is the Honeywell 2108N5000N used for?
It is an infrared gas detector intended for fixed industrial gas-monitoring applications. It provides continuous detection of suitable target gas conditions.

2. What is the basic principle behind infrared gas detection?
Target gases absorb particular wavelengths of infrared radiation. The detector evaluates this optical response to determine changes associated with gas concentration.

3. What makes infrared sensing different from catalytic gas detection?
Infrared sensing uses optical absorption, whereas catalytic detectors rely on a reaction at a sensing element. Each technology has different operating characteristics and application requirements.

4. Where should an infrared gas detector be installed?
The installation position should be determined from the target gas properties, potential leak sources, ventilation, airflow, equipment layout, and the site's gas detection engineering assessment.

5. Why can detector placement affect gas detection performance?
Gas does not necessarily travel directly from a leak to the nearest detector. Air movement, ventilation, gas density, temperature, and structural obstacles can influence how quickly gas reaches the sensing point.

6. What can cause a false gas alarm?
Possible causes include detector contamination, environmental conditions, electrical interference, incorrect calibration, unsuitable placement, configuration problems, or an actual gas release. The alarm should always be treated seriously until the cause is established.

7. What should be checked if the detector reports a fault?
Review diagnostic information first, then inspect power, wiring, connectors, environmental conditions, optical surfaces, calibration status, and the receiving control system.

8. Is regular functional testing necessary?
Yes. Gas detection equipment should be tested according to the facility's safety procedures, risk assessment, applicable requirements, and the equipment's maintenance program.

9. What should be considered when replacing the detector?
Verify the exact model, target gas configuration, mounting arrangement, electrical interface, alarm settings, system compatibility, and calibration requirements before installation.

10. How should a replacement detector be commissioned?
Confirm the mechanical installation and wiring, verify detector status and communication, perform the required functional response test, and confirm that alarms are correctly received by the associated system.