Introduction

Ingersoll Rand 47572172001 47555464001 combines the specified maintenance package with the 47555464001 water cooler seal maintenance kit used on compatible R90–R160 compressor configurations.

In a water-cooled compressor, the cooler plays a central role in controlling operating temperature. Heat generated during compression and transferred into the compressor lubricant must be effectively removed so the machine can maintain suitable thermal conditions during extended operation.

The sealing system is an important part of this process. Even when the cooler core and passages remain in good condition, deteriorated seals can allow coolant leakage or compromise the integrity of the cooling circuit. Timely seal replacement therefore provides a practical way to maintain the cooler without automatically replacing the complete heat-exchanger assembly.

The 47555464001 kit is particularly suited to planned maintenance where the water cooler is being inspected, removed, cleaned, or overhauled. Replacing service seals at the appropriate stage can help technicians restore dependable sealing performance and reduce the risk of avoidable coolant-related downtime.

For industrial compressor operators, maintaining the water-cooling circuit is more than a routine service task. Stable cooling performance supports lubricant condition, temperature control, equipment efficiency, and long-term compressor reliability.


Technical Specifications

SpecificationDetails
BrandIngersoll Rand
Maintenance Package Number47572172001
Component Part Number47555464001
Product TypeWater Cooler Seal Maintenance Kit
Module TypeWater Cooler Seal Maintenance Module
Primary FunctionWater cooler sealing maintenance
Associated SystemWater-cooled compressor
Compatible SeriesR90–R160 configurations
Service RoleCooler overhaul and preventive maintenance
Seal FunctionCooling-circuit containment
ApplicationCompressor water cooler
Pressure RatingApplication-dependent
Temperature RatingApplication-dependent
Kit DimensionsNot separately specified; configuration-dependent
Kit WeightNot separately specified; configuration-dependent
InstallationCompressor-specific water cooler assembly
CompatibilityVerify compressor model and serial number

Recommended Companion Models

ModelProduct Name
47555465001Ingersoll Rand 8000-Hour Water-Cooled Preventive Maintenance Kit
47553891001Ingersoll Rand Water-Cooled Hose Maintenance Kit
47553892001Ingersoll Rand Water-Cooled Hose Maintenance Kit
47556927001Ingersoll Rand Water Cooler Seal Maintenance Kit

Frequently Selected Alternatives

ModelProduct Name
47556927001Ingersoll Rand Water Cooler Seal Maintenance Kit
47555465001Ingersoll Rand 8000-Hour Water-Cooled Preventive Maintenance Kit
47553893001Ingersoll Rand Water-Cooled Hose Maintenance Kit
47553892001Ingersoll Rand Water-Cooled Hose Maintenance Kit


Where It Excels in Industrial Use

  • Water-cooled compressor maintenance: 47555464001 is a dedicated water cooler seal maintenance kit for compatible Ingersoll Rand R90–R160 compressor configurations.
  • Cooling-system servicing: Supports maintenance of the water cooler sealing system, helping maintain separation between cooling-water and compressor operating circuits.
  • Continuous-duty installations: Well suited to industrial compressor packages where dependable heat removal and stable cooling performance are essential for sustained operation.
  • Planned maintenance programs: Provides a focused solution for renewing service seals and related sealing components during scheduled water-cooler maintenance. 


Key Strengths at a Glance

  • Application-specific seal kit: 47555464001 is identified as a water cooler seal maintenance kit for R90–R160 compressor configurations.
  • Cooling-system integrity: Properly maintained sealing components help reduce the risk of coolant leakage and preserve the intended water-cooling circuit.
  • Targeted maintenance: Allows technicians to renew sealing components without unnecessarily replacing the complete water cooler assembly.
  • Supports thermal stability: Maintaining reliable cooler seals helps the heat exchanger perform consistently under normal compressor operating conditions.
  • Service-oriented solution: Particularly valuable during planned cooler inspection, overhaul, or preventive maintenance. 


Technical FAQs

1. What is Ingersoll Rand 47555464001?

Ingersoll Rand 47555464001 is a water cooler seal maintenance kit designed for compatible R90–R160 compressor configurations.

2. What is the relationship between 47572172001 and 47555464001?

47572172001 is the applicable maintenance package reference, while 47555464001 identifies the water cooler seal maintenance kit used within the corresponding service configuration.

3. What is the primary purpose of the water cooler seals?

The seals help maintain a controlled boundary between the cooling-water circuit and the associated compressor cooler passages, preventing unwanted leakage.

4. Why are water cooler seals important in a compressor?

A reliable seal system helps maintain coolant containment and allows the heat exchanger to perform its intended thermal-management function.

5. What can cause cooler seals to deteriorate?

Temperature cycling, pressure fluctuations, coolant chemistry, aging, installation stress, contamination, and repeated maintenance can gradually affect sealing performance.

6. What symptoms can indicate a water cooler sealing problem?

Coolant loss, visible leakage, unexplained fluid accumulation, pressure instability, or abnormal compressor temperature behavior can indicate a potential sealing issue.

7. Can a leaking water cooler affect compressor performance?

Yes. Coolant loss or reduced heat-transfer performance can contribute to elevated operating temperatures and may eventually affect compressor reliability.

8. Should the cooler itself be inspected when replacing the seals?

Yes. Cooler passages, sealing grooves, mating surfaces, fasteners, and surrounding components should be inspected for corrosion, deposits, deformation, or damage.

9. Can generic seals be substituted for 47555464001?

Substitution should not be based solely on apparent size. Seal material, geometry, temperature capability, chemical compatibility, compression characteristics, and application requirements must be confirmed.

10. What should be verified before installing 47555464001?

Confirm the compressor model, serial-number range, water-cooler configuration, existing kit number, sealing arrangement, and applicable maintenance procedure before installation.