Introduction

Ingersoll Rand 47572173001 is associated with an 8,000-hour water-cooled preventive maintenance program, while 47555464001 is specifically identified as a water cooler seal maintenance kit for compatible R90–160 series equipment. These two references address different maintenance functions and should not be treated as interchangeable products.

Water cooler sealing components play a small but important role in the overall reliability of a water-cooled compressor. Even a minor deterioration at a sealing interface can develop into leakage or maintenance problems if it is not identified during scheduled service.

For professional maintenance teams, the advantage of a dedicated seal maintenance kit is straightforward: the required sealing work can be planned as part of the compressor service cycle rather than being handled only after a leak develops. This proactive approach can make major maintenance more organized while helping preserve the integrity of the cooling system.


Technical Specifications

SpecificationDetails
BrandIngersoll Rand
Primary Part Number47572173001
Associated Part Number47555464001
47572173001 Product Type8,000-Hour Water-Cooled Preventive Maintenance Kit
47555464001 Product TypeWater Cooler Seal Maintenance Kit
Applicable Compressor FamilyR90–160 Series
Cooling TypeWater-Cooled
Service CategoryPreventive Maintenance / Cooler Sealing
Primary FunctionWater Cooler Seal Maintenance
ApplicationIndustrial Air Compressor
Component ConfigurationApplication-specific seal kit
DimensionsNot published as a single assembled dimension
WeightNot published for the complete kit
InstallationProfessional compressor maintenance
Service Interval Reference8,000-hour preventive maintenance context

Recommended Companion Models

ModelProduct Name
47552954001Temperature-Sensing Valve Maintenance Kit
475538800018K Intake Valve Service Kit
47553893001Water-Cooled Hose Maintenance Kit
475554650018,000-Hour Water-Cooled Preventive Maintenance Kit

Frequently Selected Alternatives

ModelProduct Name
47545143001Water Cooler Seal Maintenance Kit for New Cobra M90–160
475721720018,000-Hour Water-Cooled Preventive Maintenance Kit for R132–160N
475721700018,000-Hour Water-Cooled Preventive Maintenance Kit for R132–160I
475601190018,000-Hour Water-Cooled Preventive Maintenance Kit for M250


Applications

• Supports scheduled water-cooled compressor maintenance where cooler sealing components require planned inspection and renewal.

• Suitable for compatible Ingersoll Rand R90–160 series water-cooled compressor systems and related service programs.

• Designed for maintenance work involving the water cooler sealing system, helping technicians address seal-related service requirements as part of a broader compressor maintenance cycle.

• Particularly useful during major preventive-maintenance intervals when cooler integrity is being checked alongside filters, valves, hoses, and other service components.


Key Advantages

• Application-specific kit identification helps simplify preparation for water cooler maintenance.

• Supports systematic replacement of cooler sealing components rather than relying on individually selected generic seals.

• Helps maintain the integrity of the water-cooled circuit and reduce the risk of seal-related service issues.

• Provides a practical maintenance solution for facilities seeking more predictable compressor servicing and improved equipment availability.



Technical FAQs

What is Ingersoll Rand 47572173001?

47572173001 is an 8,000-hour water-cooled preventive maintenance kit associated with compatible Ingersoll Rand R132–160 compressor configurations.

What is Ingersoll Rand 47555464001?

47555464001 is a water cooler seal maintenance kit associated with compatible R90–160 series compressor equipment.

What is the primary purpose of 47555464001?

Its primary purpose is to support maintenance of the water cooler sealing system by providing the appropriate seal-related service components for the designated application.

Why are water cooler seals important in a compressor?

The seals help maintain separation and containment between the cooling medium and surrounding system interfaces. Proper sealing is essential for maintaining the integrity of the cooling circuit.

What can happen when cooler seals deteriorate?

Deteriorated seals may contribute to leakage, loss of cooling-system integrity, contamination, or the need for additional corrective maintenance.

When should water cooler seals be inspected?

Inspection should form part of scheduled compressor maintenance and should also be considered when leakage, abnormal cooling performance, or evidence of seal deterioration is observed.

Can generic seals be substituted for 47555464001 components?

Substitution should not be based on appearance alone. Material compatibility, dimensions, temperature capability, pressure conditions, and equipment-specific requirements must be verified.

Why is seal material compatibility important?

The seal material must withstand the operating environment without excessive swelling, hardening, cracking, or loss of sealing performance.

What should be checked before installing cooler seals?

The mating surfaces, grooves, cooler interfaces, fasteners, and surrounding components should be clean and free from damage, corrosion, or foreign material.

What should be verified after completing cooler seal maintenance?

The cooling circuit should be checked for leakage, correct connections, proper operating conditions, and stable compressor performance before the equipment is returned to normal service.


Look forward to your comments!Comment