Ingersoll Rand 47604753001 49032709 Standard Maintenance Service Configuration
Ingersoll Rand 47604753001 49032709 Standard Maintenance Service Configuration
0.0
Points
Brand:Ingersoll Rand Item No.:47604753001 49032709 Product Origin:USA Product Dimensions:202 × 21 × 261 mm Product Weight:0.36 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Ingersoll Rand 47604753001 49032709 Standard Maintenance Service Configuration is a complete service reference intended for structured maintenance of applicable RS-series contact-cooled rotary screw compressors. The configuration brings together the scheduled maintenance package identified by 47604753001 and the 49032709 AC/WC pre-filter pad specification under one complete model reference.
For industrial compressed-air systems, preventive maintenance is not simply a matter of replacing individual consumables. Air filtration, separation, cooling, lubrication, and inspection activities work together to preserve compressor efficiency and operating stability. Maintaining the pre-filtration stage is especially important because the condition of the intake environment directly influences the loading of downstream filtration components.
The 47604753001 49032709 configuration is therefore suited to maintenance programs that prioritize organized service planning, correct component identification, and repeatable maintenance procedures. Before installation, the compressor model and serial number should be confirmed to ensure that the complete configuration corresponds with the installed machine and its current parts documentation.
• Designed around scheduled maintenance requirements for applicable Ingersoll Rand RS-series contact-cooled rotary screw compressors.
• The complete 47604753001 49032709 configuration combines a standard 1-year / 6,000- to 8,000-hour maintenance service reference with an AC/WC pre-filter pad specification.
• Well suited to production plants, utilities, process facilities, workshops, and other compressed-air installations where controlled maintenance intervals are important.
• Supports cleaner compressor intake conditions by incorporating the pre-filter element into the overall service configuration.
• Particularly useful for maintenance teams that prefer ordering and identifying the complete configuration by its full model reference rather than managing individual service references separately.
Key Strengths at a Glance
• Complete Model Reference: 47604753001 49032709.
• Service Configuration: Standard maintenance configuration with an AC/WC pre-filter pad reference.
• Maintenance Interval: 1 year / 6,000-8,000 operating hours, subject to the applicable compressor maintenance schedule.
• Filtration Focus: Supports the compressor air-intake pre-filtration arrangement and helps reduce the ingress of airborne contaminants.
• Industrial Serviceability: Suitable for planned maintenance programs where consistent replacement of service items helps maintain compressor operating reliability.
• Application Flexibility: Intended for applicable RS185-260I/IE and related RS-series configurations according to equipment specification and service documentation.
Technical FAQs
1. What does the complete Ingersoll Rand 47604753001 49032709 model reference represent?
The complete reference identifies a standard scheduled maintenance service configuration incorporating the 47604753001 maintenance kit specification and the 49032709 AC/WC pre-filter pad specification.
2. What maintenance interval is associated with 47604753001?
The 47604753001 reference is used for a standard 1-year / 6,000-8,000-hour maintenance service interval, with the exact interval determined by the compressor model, operating hours, and applicable maintenance schedule.
3. What is the function of 49032709 within the complete configuration?
49032709 is an AC/WC pre-filter pad used within the compressor air-filtration arrangement to provide an initial stage of contaminant capture before air reaches the primary filtration system.
4. Which compressor systems should be checked before installing this configuration?
The compressor model, serial number, cooling arrangement, maintenance generation, and existing filtration arrangement should all be checked against the applicable parts documentation before installation.
5. Does the complete configuration affect the compressor air-intake system?
Yes, the pre-filter element forms part of the air-intake filtration arrangement and should be installed with the correct orientation and seating to prevent bypass around the filtration surface.
6. What should be inspected during installation?
The technician should inspect the pre-filter housing, sealing surfaces, retaining hardware, surrounding ducting, and adjacent air-filtration components for contamination, damage, or improper seating.
7. Can the pre-filter pad be replaced independently during service?
The serviceability of the pre-filter pad independently from the complete configuration depends on the maintenance procedure and parts structure applicable to the specific compressor installation.
8. How does a clean pre-filter support compressor operation?
A properly maintained pre-filter helps limit the amount of airborne dust and particulate matter entering the primary air-filtration system, supporting stable intake conditions and reducing unnecessary loading of downstream filtration components.
9. Is this configuration suitable for high-dust operating environments?
This is a standard maintenance configuration rather than a dedicated high-dust service kit, so installations exposed to unusually heavy particulate loading should be evaluated against the manufacturer's recommended high-dust maintenance requirements.
10. What is the recommended approach when the existing part reference differs from 49032709?
The technician should verify the compressor serial number, current parts revision, and supersession information before substitution, because visually similar pre-filter elements may have different material, mounting, or application requirements.