Brand:Ingersoll Rand Item No.: 47708242_A Product Origin:USA Product Dimensions:109 × 64 × 58 mm Product Weight:0.30 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Ingersoll Rand 47708242_A Cooling Assembly is intended for compressor cooling applications where reliable thermal control is required for sustained industrial operation. Its primary role is to support heat transfer within the applicable cooling system and help maintain suitable operating conditions as compressor load changes.
Cooling assemblies are closely integrated with the compressor's fluid circuits and mechanical layout. A correctly matched replacement therefore provides more than a simple component exchange; it preserves the intended relationship between cooling capacity, flow paths, connections, and operating conditions.
For maintenance departments and industrial service contractors, the 47708242_A reference offers a clear identification point when planning replacement work. Before installation, the part number should be checked against the compressor's identification data and current technical documentation.
Technical Specifications
Specification
Details
Manufacturer
Ingersoll Rand
Part Number
47708242_A
Product Type
Cooling Assembly
Primary Application
Industrial compressor cooling
Main Function
Heat dissipation and thermal regulation
System Integration
Compressor cooling circuit
Installation
Replacement installation in the designated equipment configuration
Connection Arrangement
Configuration-specific
Cooling Medium
Dependent on compressor configuration
Operating Environment
Industrial compressed-air applications
Service Application
Planned maintenance and corrective replacement
Dimensions
Verify against the applicable Ingersoll Rand equipment documentation
Weight
Verify against the applicable Ingersoll Rand equipment documentation
Recommended Companion Models
Model
Product Name
47708239_A
Oil Cooler
47708240_A
Aftercooler
47704507001
Standard Oil Cooler
47704508001
Standard After-Cooler
Frequently Selected Alternatives
Model
Product Name
47569423001
Standard Oil Cooler
47569424001
Standard After-Cooler
47569427001
Harsh Water Oil Cooler
47569428001
Harsh Water After-Cooler
Where It Excels in Industrial Use
• Intended for industrial compressor installations where dependable heat removal is essential to maintaining stable operating conditions.
• Performs an important role in the compressor cooling circuit, supporting consistent thermal control during extended production cycles.
• Suitable for demanding plant environments in which compressors operate under variable loads, high utilization, or continuous-duty conditions.
• Provides a practical replacement reference for maintenance teams servicing compatible Ingersoll Rand compressor equipment.
Key Strengths at a Glance
• Designed around the thermal-management requirements of the applicable compressor system.
• Supports efficient transfer of unwanted heat away from critical operating circuits.
• Helps maintain consistent temperature behavior during changing compressor loads.
• Suitable for planned service work as well as corrective replacement when the specified part number is required.
• Integrates with the existing compressor arrangement when application and equipment references are correctly matched.
Technical FAQs
1. What is the function of the 47708242_A cooling assembly?
The 47708242_A cooling assembly is used within the compressor thermal-management system to assist with heat dissipation and temperature control.
2. Which compressor equipment is suitable for this part?
Application depends on the exact compressor configuration, so the machine model, serial number, cooling arrangement, and applicable parts documentation should be verified before ordering.
3. How does the assembly affect compressor operating stability?
Effective heat removal helps keep the compressor within its intended thermal operating range, which supports stable performance during sustained loading.
4. What interfaces should be inspected before installation?
Technicians should verify the fluid connections, mounting points, sealing surfaces, hose routing, and surrounding components against the applicable equipment configuration.
5. Is the cooling assembly appropriate for scheduled maintenance?
It can be used during planned maintenance when inspection or the applicable service procedure indicates that the existing cooling assembly requires replacement.
6. What can cause reduced cooling performance after installation?
Restricted flow, contamination, incorrect connections, damaged seals, inadequate system cleaning, or unsuitable operating conditions can reduce cooling effectiveness.
7. What operating symptoms may indicate a cooling-system problem?
Higher-than-normal operating temperatures, thermal alarms, reduced cooling efficiency, visible leakage, or abnormal temperature fluctuations may indicate that the cooling system requires inspection.
8. Should the cooling circuit be inspected before fitting the replacement?
Yes, the circuit should be checked for contamination, damaged hoses, worn seals, restricted passages, and other conditions that could affect the performance of the replacement assembly.
9. What commissioning checks are recommended after installation?
The system should be checked for secure connections and leakage, then operated under controlled conditions while temperatures and other relevant operating parameters are monitored.
10. Why is exact part-number verification important for 47708242_A?
Exact verification helps ensure that the replacement has the correct physical interfaces, installation arrangement, and thermal characteristics for the intended compressor configuration.