Brand:Ingersoll Rand Item No.: 47579355001 23969298 Product Origin:USA Product Dimensions:110 × 66.8 × 50 mm Product Weight:0.30 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Ingersoll Rand 47579355001 23969298 configuration combines an 8,000-hour water-cooled maintenance kit with the specified 23969298 condensate discharge solenoid valve. It is intended for compatible IRN 37–45 kW oil-free compressor systems and supports planned service of the compressor's condensate management system.
The 23969298 valve provides electrically controlled condensate discharge within the applicable drainage circuit. Reliable operation of this component helps the compressor remove accumulated moisture as intended, reducing the risk of drainage-related service problems.
The complete configuration should be matched to the compressor model, production generation, and serial-number range before installation. Where applicable, 23969298 may serve as the replacement reference for 22410286.
Configuration-dependent; verify valve and connection envelope against current service data
Weight
Configuration-dependent; verify final packaged weight from supplier data
Recommended Companion Models
Model
Product Name
47578986001
2,000-Hour Maintenance Service Kit
47579188001
4,000-Hour Maintenance Service Kit
47579614001
8,000-Hour Air-Cooled Maintenance Kit
47579355001
8,000-Hour Water-Cooled Maintenance Kit
Frequently Selected Alternatives
Model
Product Name
22483192
2-Way 0.50-Inch NPT Water Shut-Off Solenoid Valve
67981688
Check Valve
22338115
Air Filter Element
39911615
Ultra Coolant Filter
Where It Excels in Industrial Use
• Designed for compatible Ingersoll Rand IRN 37–45 kW oil-free water-cooled compressor systems requiring scheduled 8,000-hour maintenance.
• Combines maintenance kit reference 47579355001 with 23969298 as one complete service configuration.
• Integrates the specified condensate drain solenoid valve into planned compressor maintenance activities.
• Suitable for industrial compressed-air installations where reliable automatic condensate discharge helps maintain stable system operation.
• Supports maintenance teams replacing service components before condensate management problems develop into operating or reliability issues.
Key Strengths at a Glance
• Complete service configuration: 47579355001 23969298 is treated as one complete maintenance configuration.
• Condensate control: 23969298 is identified as a condensate discharge solenoid valve for compatible Ingersoll Rand compressor systems.
• Automatic drainage support: The solenoid-operated valve helps control the discharge of accumulated condensate from the applicable drainage circuit.
• Water-cooled maintenance application: The configuration is associated with the 8,000-hour water-cooled service arrangement.
• Replacement compatibility: 23969298 is also identified as a replacement reference for 22410286 in applicable compressor configurations.
Technical FAQs
1. What is the purpose of the 47579355001 23969298 configuration?
It combines the 47579355001 8,000-hour water-cooled maintenance kit with the specified 23969298 condensate drain solenoid valve as one complete service configuration.
2. What type of component is 23969298?
23969298 is a condensate discharge solenoid valve used in the automatic condensate drainage system of compatible Ingersoll Rand compressors.
3. What does the condensate drain valve control?
The valve controls the discharge path for accumulated condensate, allowing the compressor's drainage system to release collected moisture at the appropriate time.
4. Which compressor systems are associated with this configuration?
The configuration is associated with compatible Ingersoll Rand IRN 37–45 kW oil-free water-cooled compressor systems, subject to exact model and serial-number verification.
5. Can 23969298 replace 22410286?
23969298 is identified in service-parts references as a replacement for 22410286 in applicable configurations, but the compressor's specific parts information should be checked before substitution.
6. Why is automatic condensate drainage important?
Reliable condensate removal helps prevent accumulated moisture from interfering with the drainage system and supports proper operation of the compressor's moisture-management circuit.
7. What symptoms can indicate a problem with the condensate drain solenoid valve?
Failure to discharge condensate, continuous leakage, abnormal cycling, or an electrical actuation problem can indicate that the valve or its control circuit requires inspection.
8. What should be checked before installing 23969298?
The technician should verify the compressor identification, valve part number, electrical interface, drain-line connections, flow path, and applicable service instructions.
9. Should the condensate system be isolated before valve replacement?
Yes. The compressor should be shut down and the relevant pressure and condensate circuits made safe before removing the existing valve.
10. What should be verified after installing the solenoid valve?
The technician should check the electrical connection, mechanical sealing, drainage path, valve actuation, and condensate discharge function before returning the compressor to normal service.