Ingersoll Rand

  1. Home
  2. Products
  3. Ingersoll Rand
  4. Ingersoll Rand 47579615001 67707398 Air-Cooled Service and Check Valve Configuration
Ingersoll Rand 47579615001 67707398 Air-Cooled Service and Check Valve Configuration

Ingersoll Rand 47579615001 67707398 Air-Cooled Service and Check Valve Configuration

0.0
Points

Brand:Ingersoll Rand
Item No.: 47579615001 67707398
Product Origin:USA
Product Dimensions:110 × 66.8 × 50 mm
Product Weight:0.30 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

47588445001 24509200-147588445001 24509200-247588445001 24509200-447588445001 24509200-3

Introduction

The Ingersoll Rand 47579615001 67707398 Air-Cooled Service and Check Valve Configuration combines an 8,000-hour air-cooled maintenance package with the specified 67707398 check valve. The primary service reference is associated with applicable IRN 90–160 kW oil-free compressor systems, while the valve provides directional flow control within the applicable compressed-air circuit.

Check valves are important wherever compressed air must be prevented from returning through a protected section of the system. During major maintenance, inspection of valve condition and correct installation can help maintain the intended pressure and flow behavior of the compressor circuit.

This complete configuration is intended to simplify scheduled service planning by keeping the major maintenance reference and specified valve component together. Before installation, the compressor model, serial number, valve arrangement, connection details, and current Ingersoll Rand parts documentation should be verified.

Technical Specifications

SpecificationDetails
Complete Model Reference47579615001 67707398
Primary Maintenance Reference47579615001
Associated Component67707398
Product ConfigurationAir-cooled maintenance service and check valve
Maintenance Interval8,000 hours
Compressor TechnologyOil-free rotary screw compressor
Applicable PlatformIRN 90–160 kW oil-free configurations
Primary Service TypeScheduled air-cooled preventive maintenance
Component TypeCheck valve
Primary FunctionDirectional compressed-air flow control
System FunctionPrevention of reverse airflow through the applicable circuit
InstallationApplicable compressor valve location
DimensionsNot separately specified for the complete configuration
WeightNot separately specified for the complete configuration
CompatibilityVerify compressor model, serial number, valve arrangement, connection configuration, and current parts documentation

Recommended Companion Models

ModelProduct Name
IRN90K-2SIngersoll Rand IRN90K-2S Oil-Free Rotary Screw Compressor
IRN110K-2SIngersoll Rand IRN110K-2S Oil-Free Rotary Screw Compressor
IRN132K-2SIngersoll Rand IRN132K-2S Oil-Free Rotary Screw Compressor
IRN160K-2SIngersoll Rand IRN160K-2S Oil-Free Rotary Screw Compressor

Frequently Selected Alternatives

ModelProduct Name
47578987001IRN160K-of 2,000-Hour Maintenance Kit
47579189001IRN160K-of 4,000-Hour Maintenance Package
47579356001IRN160K-of 8,000-Hour Water-Cooled Maintenance Kit
67981688Ingersoll Rand Check Valve for Applicable Compressor Configurations


Where It Excels in Industrial Use

• The complete 47579615001 67707398 configuration combines an 8,000-hour air-cooled maintenance package with the specified check valve for applicable Ingersoll Rand oil-free compressor systems.

• Designed for scheduled major maintenance on compatible IRN 90–160 kW oil-free air-cooled compressor installations used in manufacturing, process-air, utility, and industrial production environments.

• Supports service programs that address both routine maintenance requirements and critical compressed-air flow-control components during an extended maintenance interval.

• The 67707398 check valve is used to control compressed-air flow in the applicable compressor system, helping prevent reverse flow through the protected circuit.

• Provides a consolidated reference for maintenance teams coordinating the major service package with replacement of the specified valve component.


Key Strengths at a Glance

8,000-hour service coverage: 47579615001 is an air-cooled 8,000-hour maintenance package associated with applicable IRN 90–160 kW oil-free compressor configurations.

Directional flow control: 67707398 is identified as a check valve for applicable Ingersoll Rand compressor equipment.

Backflow prevention: The valve permits flow in the intended direction while helping restrict reverse air movement through the associated circuit.

Maintenance integration: Combining the service package with the specified valve simplifies parts identification and preparation for planned compressor maintenance.

System-specific fit: Compressor model, serial number, valve location, connection arrangement, and current parts documentation should be verified before installation.


 Technical FAQs

1. What does the complete 47579615001 67707398 configuration represent?

It represents an 8,000-hour air-cooled maintenance configuration combined with the specified 67707398 check valve for applicable Ingersoll Rand oil-free compressor systems.

2. What is 47579615001?

47579615001 is an 8,000-hour air-cooled maintenance package associated with applicable IRN 90–160 kW oil-free compressor configurations, including the IRN160K-of platform.

3. What is the function of 67707398?

67707398 is a check valve that controls airflow through the applicable compressor circuit and helps prevent compressed air from flowing backward when system conditions could otherwise allow reverse flow.

4. Why is a check valve important in a compressor system?

A properly functioning check valve helps maintain intended airflow direction and can reduce unwanted pressure migration or backflow into upstream compressor components.

5. Is 67707398 the same as a minimum-pressure valve?

No. A check valve and a minimum-pressure valve perform different functions. 67707398 is identified as a check valve, while minimum-pressure valves are designed to maintain a specified pressure level within the compressor system.

6. What should be checked before installing 67707398?

The technician should verify the compressor model and serial number, valve location, flow direction, connection configuration, sealing arrangement, and current parts documentation before installation.

7. Can a check valve be installed in either flow direction?

No. A check valve must be installed according to its specified flow direction. Incorrect orientation can restrict normal airflow or prevent the valve from providing the intended backflow protection.

8. What conditions can indicate a check-valve problem?

Reverse airflow, abnormal pressure behavior, leakage through the valve, unusual pressure loss, or failure of the valve to open or close correctly can indicate that inspection or replacement is required.

9. What should be inspected when replacing 67707398?

The valve body, connection points, mating surfaces, seals, surrounding piping, and flow-direction markings should be inspected for contamination, damage, leakage, or installation conditions that could affect valve operation.

10. Is 67707398 included in every version of 47579615001?

The requested configuration combines 47579615001 with 67707398, but maintenance-package contents can vary by compressor generation and configuration. The applicable parts list should therefore be checked against the machine serial number before ordering.


Look forward to your comments!Comment
Latest comments
Tags:
Need Assistance? Chat with Us on WhatsApp!
Need Assistance? Click to Inquire
Back to top