Brand:Schneider PLC Item No.:NW10N1 Product Origin:France Product Dimensions:352 x 537 x 297 mm Product Weight:65 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Schneider NW10N1 Masterpact Air Circuit Breaker is designed for low-voltage power distribution systems requiring high-current switching and circuit protection. Its 1000 A frame category makes it relevant to industrial and commercial installations where electrical distribution equipment must handle substantial loads.
As part of the Masterpact NW family, the NW10N1 can be configured with compatible protection units and accessories. The complete configuration determines its protection functions, installation arrangement, and operating characteristics.
For maintenance and replacement projects, selecting the correct version is essential. Buyers should confirm the full product reference, pole arrangement, fixed or drawout construction, trip-unit type, and accessory requirements before ordering.
Technical Specifications
Parameter
Description
Brand
Schneider Electric
Model
NW10N1
Product Name
Masterpact NW Circuit Breaker
Product Type
Air Circuit Breaker (ACB)
Product Family
Masterpact NW
Frame Rating
1000 A
Performance Category
N1
Application
Low-voltage power distribution
Protection Functions
Dependent on installed trip unit
Mounting Type
Fixed or drawout, depending on reference
Pole Configuration
Depends on the complete product reference
Dimensions (W × H × D)
537 × 352 × 297 mm
Weight
65 kg / 143.30 lb
Note: Confirm the rated operational voltage, short-circuit breaking capacity, trip-unit reference, and mounting configuration against the product nameplate and applicable manufacturer documentation.
Recommended Related Models
The following Schneider Electric Masterpact NW models are useful for comparing different frame ratings and performance categories:
Schneider NW08N1 Circuit Breaker
Schneider NW10H1 Circuit Breaker
Schneider NW10H2 Circuit Breaker
Schneider NW12N1 Circuit Breaker
These models belong to the broader Masterpact NW range. Their electrical ratings and configurations differ, so they should not be considered direct replacements without technical verification.
Popular Related Models
Other Schneider Electric circuit breaker models relevant to industrial power distribution include:
Schneider NW08N1 Circuit Breaker
Schneider NW10N1 Circuit Breaker
Schneider NW12N1 Circuit Breaker
Schneider NW16N1 Circuit Breaker
Schneider NW20H1 Circuit Breaker
Schneider NW32H1 Circuit Breaker
When sourcing the Schneider NW10N1, confirm the full reference and configuration, including the trip unit, pole arrangement, and mounting type. Accurate identification helps ensure compatibility with the intended switchboard and electrical protection system.
Applications
The Schneider NW10N1 is part of Schneider Electric's Masterpact NW air circuit breaker range, designed for low-voltage power distribution systems. With a 1000 A frame rating, it is suitable for protecting high-current electrical circuits in industrial, commercial, and infrastructure installations.
Typical applications include:
Industrial power distribution: Protects incoming power circuits and distribution feeders in manufacturing plants.
Commercial buildings: Supports electrical distribution in large buildings, business complexes, and public facilities.
Low-voltage switchgear: Integrates into appropriately designed switchboards and distribution panels.
Infrastructure projects: Provides circuit protection for electrical installations in transportation and utility facilities.
Power management systems: Helps maintain controlled power distribution and reliable circuit isolation.
Advantages and Key Features
1000 A frame rating
The NW10N1 is designed for applications requiring a higher current capacity within the Masterpact NW product range. Its frame rating makes it suitable for substantial low-voltage distribution circuits.
N1 breaking performance
The N1 performance category is intended for applications with defined short-circuit protection requirements. The actual breaking capacity must be evaluated at the installation's operating voltage.
Configurable installation options
Depending on the complete product reference, Masterpact NW breakers are available in different mounting arrangements and pole configurations. This flexibility supports integration into different switchgear designs.
Protection and control flexibility
Compatible trip units and accessories allow the breaker to be configured for the protection and monitoring requirements of an electrical distribution system.
Suitable for demanding electrical environments
The Masterpact NW platform is designed for professional power distribution applications where dependable switching, protection, and maintenance are important.
Technical FAQs
Q1: What is the Schneider NW10N1 used for?
The NW10N1 is an air circuit breaker designed to protect low-voltage electrical distribution circuits against overloads and short circuits when equipped with a suitable protection unit.
Q2: What is the rated current of the NW10N1?
The NW10N1 belongs to the 1000 A frame category. The actual rated current and protection settings depend on the installed sensor and trip-unit configuration.
Q3: What does the N1 designation represent?
N1 identifies the breaker’s short-circuit performance category. Its breaking capacity must be checked at the applicable operating voltage and against the electrical system's prospective fault current.
Q4: Which protection functions are available?
Available functions depend on the installed trip unit. Depending on the configuration, protection may include long-time, short-time, instantaneous, and ground-fault protection.
Q5: Can the NW10N1 be used in a three-phase electrical system?
Yes. A compatible three-pole configuration can be used in three-phase distribution systems. The appropriate pole arrangement should be selected according to the system design.
Q6: Is the NW10N1 available as a drawout circuit breaker?
Masterpact NW breakers are available in fixed and drawout arrangements, depending on the product reference. Confirm the exact version before selecting a replacement or planning installation.
Q7: Can the breaker support remote operation?
Remote operation may be available with compatible electrical operating mechanisms and accessories. The required components depend on the specific breaker configuration.
Q8: What should be checked before installing the NW10N1?
Verify rated voltage, current, breaking capacity, trip-unit compatibility, pole arrangement, mounting type, terminal connections, and accessory configuration. Installation should be performed by qualified electrical personnel.
Q9: What are common causes of unexpected tripping?
Potential causes include overloads, short circuits, incorrect protection settings, wiring faults, and abnormal operating conditions. Review the trip indication and investigate the fault before resetting the breaker.
Q10: Can the NW10N1 replace an NW08N1?
Not automatically. Although both belong to the Masterpact NW family, they have different frame ratings. Physical compatibility, protection settings, terminal arrangements, and switchboard requirements must be verified before replacement.