Product Introduction

The Allen-Bradley 22C-D105A103 is a PowerFlex 400 adjustable frequency AC drive developed for fan and pump applications. With a rated output of 55 kW (75 HP) and 105 A at 480V AC, it is intended for larger motor-driven systems that need adjustable speed control.

This model belongs to the PowerFlex 400 Frame E range and features an IP30 (NEMA 1 / UL Type 1) enclosure, a fixed keypad, and RS-485 communication. Its application-oriented functions make it suitable for HVAC equipment, water systems, industrial ventilation, and other variable-torque installations.

When replacing an existing drive or specifying a new system, confirm the complete catalog number, electrical ratings, enclosure requirements, communication configuration, and motor load. Matching the power rating alone does not guarantee that another drive is a direct replacement.

Technical Specifications

Parameter

Specification

Brand

Allen-Bradley

Model

22C-D105A103

Product Series

PowerFlex 400

Product Type

AC Drive / Variable Frequency Drive

Application

Fan and Pump Control

Rated Power

55 kW / 75 HP

Input Voltage

480V AC

Input Phase

3-phase

Input Voltage Range

340–528V AC

Rated Output Current

105 A

Frame Size

Frame E

Enclosure Rating

IP30 (NEMA 1 / UL Type 1)

Operator Interface

Fixed Keypad

Communication Interface

RS-485

Braking IGBT

Not Included

Dimensions

370 × 605.5 × 259.2 mm

Weight

51.2 kg / 112.88 lb

Recommended Related Models

The following PowerFlex 400 models offer different power and current ratings for comparison when selecting a drive for a fan or pump system:

  • 22C-D088A103 – 45 kW (60 HP), 88 A, 480V AC, three-phase.

  • 22C-D072A103 – 37 kW (50 HP), 72 A, 480V AC, three-phase.

  • 22C-D142A103 – 75 kW (100 HP), 142 A, 480V AC, three-phase.

Check the motor's rated current, load characteristics, and installation requirements before selecting an alternative.

Popular Related Models

  • Allen-Bradley 22C-D060A103 PowerFlex 400 AC Drive

  • Allen-Bradley 22C-D088A103 PowerFlex 400 AC Drive

  • Allen-Bradley 22C-D105A103 PowerFlex 400 AC Drive

  • Allen-Bradley 22C-D142A103 PowerFlex 400 AC Drive

  • Allen-Bradley 22C-D170A103 PowerFlex 400 AC Drive

  • Allen-Bradley 22C-D208A103 PowerFlex 400 AC Drive


Applications

The Allen-Bradley 22C-D105A103 PowerFlex 400 AC Drive is designed for variable-speed control of fan and pump systems in commercial and industrial facilities. It can help regulate motor speed according to process demand, supporting more efficient operation in applications where flow and pressure requirements change over time.

Typical applications include:

  • HVAC supply and return fans

  • Cooling tower and condenser water pumps

  • Industrial ventilation systems

  • Water supply and wastewater treatment

  • Process cooling and circulation pumps

  • Building automation and utility systems

Its fan-and-pump-oriented design makes it suitable for systems that require reliable motor speed regulation and integration into larger automation installations.


Advantages and Key Features

  • High-power motor control: Rated at 55 kW (75 HP) with a 105 A output current for larger fan and pump installations.

  • Fan and pump optimization: Designed for variable-torque applications where motor speed can be adjusted to match system demand.

  • Three-phase power input: Operates on a 480V AC, three-phase supply.

  • Integrated RS-485 communication: Supports serial communication for connection with compatible control and monitoring systems.

  • Built-in operator interface: The fixed keypad provides a local interface for drive operation and parameter configuration.

  • Industrial enclosure: The IP30, NEMA/UL Type 1 enclosure is intended for installation in a suitable protected electrical environment.

  • Application-oriented functions: PowerFlex 400 drives include features intended for fan and pump systems, helping simplify motor control and system integration.


Technical FAQs

1. What type of applications is the 22C-D105A103 designed for?

It is designed primarily for variable-torque applications, including industrial fans, ventilation equipment, cooling systems, and water pumps.

2. What is the rated motor power of this drive?

The drive is rated at 55 kW (75 HP) for its 480V AC, three-phase configuration.

3. What is its rated output current?

The catalog rating is 105 A. The connected motor's nameplate current and application duty should be checked before selecting the drive.

4. What input power supply does it require?

It is a 480V AC, three-phase model. The published technical data specifies an input voltage range of 340–528V AC. The actual supply must remain within the applicable operating limits.

5. Does the 22C-D105A103 support RS-485 communication?

Yes. This catalog configuration includes an RS-485 communication interface for compatible serial communication and control arrangements.

6. Can the drive be controlled by a PLC?

Yes. It can be incorporated into a PLC-based system using its supported control I/O and RS-485 communication. The control method and communication parameters must be configured for the connected PLC or interface.

7. Does this model have a built-in braking IGBT?

No. The 22C-D105A103 version is specified without a braking IGBT. If the application requires dynamic braking, confirm the appropriate external braking solution and drive compatibility.

8. Does it include a local operator keypad?

Yes. This version has a fixed keypad for local operation, monitoring, and parameter setup.

9. What should be checked before commissioning?

Verify the supply voltage, motor nameplate data, wiring, grounding, protective devices, control connections, and drive parameters. Confirm that the motor and load are suitable for the drive's current and power ratings before starting the system.

10. What should be checked if the motor does not run?

Check the incoming power supply, drive status and fault display, run command source, enable and interlock signals, motor wiring, and configured start/stop parameters. Correct the cause of any active fault before resetting and restarting the drive.