Brand:Allen Bradley PLC Item No.:22C-D208A103 Product Origin:USA Product Dimensions:425 x 850 x 264 mm Product Weight:88 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Allen-Bradley 22C-D208A103 is a high-capacity member of the PowerFlex 400 adjustable frequency drive family. Designed primarily for fan and pump applications, it provides variable-speed control for large motors used in HVAC systems, industrial ventilation, water treatment, and process fluid circulation.
With a rated output of 110 kW (150 HP) and 208 A, this model is intended for installations requiring substantial motor capacity. Its PowerFlex 400 platform supports integration into industrial control environments through its available control and communication features.
For equipment replacement or new installations, verify the complete catalog number, input voltage, motor current, enclosure requirements, control interface, and braking requirements. A drive with a similar power rating is not necessarily a direct replacement.
Technical Specifications
Parameter
Specification
Brand
Allen-Bradley
Model
22C-D208A103
Product Series
PowerFlex 400
Product Type
AC Drive / Variable Frequency Drive
Application
Fan and Pump Control
Rated Power
110 kW / 150 HP
Input Voltage Rating
480V AC
Input Voltage Range
340–528V AC
Input Phase
3-phase
Frequency Rating
50–60 Hz
Rated Output Current
208 A
Frame Size
Frame F
Enclosure Rating
IP30 (NEMA 1 / UL Type 1)
Mounting Type
Panel Mount
Operator Interface
Fixed Keypad with LED Display
Communication Interface
RS-485
Braking IGBT
Not Included
EMC Filter
Not Included
Dimensions
425 × 850 × 264 mm
Weight
88 kg / 194.01 lb
Recommended Related Models
The following PowerFlex 400 models offer different power and current ratings for comparison in similar industrial fan and pump applications:
These models have different current ratings and frame configurations. Check the motor nameplate, operating conditions, and installation requirements before choosing an alternative.
Popular Related Models
Allen-Bradley 22C-D088A103 PowerFlex 400 AC Drive
Allen-Bradley 22C-D105A103 PowerFlex 400 AC Drive
Allen-Bradley 22C-D142A103 PowerFlex 400 AC Drive
Allen-Bradley 22C-D170A103 PowerFlex 400 AC Drive
Allen-Bradley 22C-D208A103 PowerFlex 400 AC Drive
Allen-Bradley 22C-D260A103 PowerFlex 400 AC Drive
Allen-Bradley 22C-D310A103 PowerFlex 400 AC Drive
Technical clarification: The 22C-D208A103 is confirmed as a Frame F, 480V AC, 208 A PowerFlex 400 drive with a fixed keypad, RS-485 communication, and no built-in braking IGBT. Its rated power is 110 kW (150 HP).
Applications
The Allen-Bradley 22C-D208A103 PowerFlex 400 AC Drive is a high-power variable frequency drive designed for large industrial fan and pump systems. With a rated output of 110 kW (150 HP) and a 208 A output current, it provides adjustable speed control for three-phase AC motors in demanding variable-torque applications.
Typical applications include:
Large HVAC air handling and ventilation systems
Industrial exhaust and circulation fans
Cooling tower and condenser water pumps
Water supply and wastewater treatment facilities
Industrial process cooling and fluid circulation
Large-scale building utility systems
By adjusting motor speed to match actual system demand, the drive can support stable process operation and help reduce unnecessary energy consumption in suitable variable-torque applications.
Advantages and Key Features
High-power motor control: Provides a 110 kW (150 HP) rating and 208 A output current for large motor-driven equipment.
Fan and pump application design: Developed for variable-torque loads commonly found in HVAC, water management, and industrial process systems.
480V three-phase configuration: Designed for compatible industrial AC power installations.
RS-485 communication: Supports serial communication with compatible automation and monitoring equipment.
Local keypad operation: Provides an operator interface for monitoring drive status and adjusting operating parameters.
Industrial enclosure: The IP30 (NEMA 1 / UL Type 1) enclosure is intended for installation in a suitable protected electrical environment.
High-power frame design: Supports integration into larger fan and pump control installations.
Technical FAQs
1. What is the primary function of the 22C-D208A103?
It is an adjustable frequency AC drive used to regulate the speed of three-phase AC motors, particularly in large fan and pump applications.
2. What is the rated power of this model?
The 22C-D208A103 is rated at 110 kW (150 HP) for its specified 480V three-phase configuration.
3. What is its rated output current?
Its rated output current is 208 A. The connected motor's nameplate current and actual load conditions should be checked during drive selection.
4. What input power supply does it use?
This catalog model is designed for a 480V AC three-phase power system. Confirm the permitted input voltage range on the product nameplate and applicable technical documentation.
5. Does the drive support RS-485 communication?
Yes. The PowerFlex 400 family supports RS-485 serial communication for connection to compatible automation and monitoring systems.
6. Can it be integrated with a PLC?
Yes. It can be incorporated into a PLC-based control system through supported control connections and serial communication. The wiring, command source, and communication parameters must be configured correctly.
7. Does the 22C-D208A103 include a braking IGBT?
This catalog configuration should be checked against its nameplate and technical documentation before a braking arrangement is specified. Do not assume that a braking IGBT is included.
8. What is the purpose of the local keypad?
The keypad provides a local interface for drive operation, status monitoring, and parameter configuration, subject to the configured command and reference sources.
9. What should be checked before commissioning?
Verify the incoming supply, motor nameplate data, grounding, power and control wiring, protective devices, ventilation, and drive parameters. Confirm that the drive is correctly rated for the motor and load.
10. What should be checked if the drive trips during operation?
Review the displayed fault code and operating history. Check the supply voltage, motor current, load condition, wiring, cooling and ventilation, and configured protection parameters. Correct the underlying issue before resetting the drive.