Brand:Schneider PLC Item No.:NW40N1 Product Origin:France Product Dimensions:352 x 537 x 297 mm Product Weight:80 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
Introduction – Schneider MasterPact NW40N1 Power Circuit Breaker
The Schneider MasterPact NW series is designed for low-voltage power distribution systems that require dependable circuit protection and switching performance. It is used in electrical installations where equipment protection, operational continuity, and coordination between protective devices are important.
A MasterPact NW circuit breaker must be selected according to the electrical characteristics of the installation. Rated current, short-circuit breaking capacity, trip-unit functions, and mounting configuration all influence whether a particular model is suitable.
For the NW40N1 reference, buyers should confirm the exact catalog number and nameplate details before ordering. This is particularly important when replacing existing equipment or matching a breaker to an established switchboard.
Technical Specifications – Product Details and Dimensions
Parameter
Specification
Brand
Schneider Electric
Product Series
MasterPact NW
Model Reference
NW40N1
Product Type
Air Circuit Breaker
Frame Designation
NW40
Dimensions (W × H × D)
352 × 537 × 297 mm
Weight
80 kg (176.37 lb)
Application
Low-voltage power distribution and circuit protection
Dimensions and weight are based on the supplied product information. The exact NW40N1 catalog designation and its electrical ratings should be checked against the product nameplate and Schneider Electric documentation before purchase.
Recommended Related Models – Schneider MasterPact NW Range
The following are related MasterPact NW model references. Confirm their electrical ratings and configurations before treating them as alternatives.
Model
Product Type
NW32N1
Air Circuit Breaker
NW40N1
Air Circuit Breaker
NW40H1
Air Circuit Breaker
NW40H2
Air Circuit Breaker
Popular Related Models – MasterPact NW Circuit Breakers
NW32N1 – A related NW frame reference for high-capacity distribution applications.
NW40N1 – The model reference covered on this page.
NW40H1 – An NW40 circuit-breaker variant with a different interrupting-performance designation.
NW40H2 – Another NW40 variant for applications with different short-circuit requirements.
The N1, H1, and H2 versions have different electrical performance characteristics and should not be considered interchangeable without checking the system requirements and complete catalog references.
Applications – High-Capacity Low-Voltage Power Distribution
The Schneider MasterPact NW40N1 is identified as a circuit-breaker model reference for high-capacity electrical distribution applications. MasterPact NW circuit breakers are used in industrial plants, commercial facilities, and large electrical installations where reliable switching and circuit protection are essential.
Typical application areas include:
Main low-voltage distribution switchboards
Industrial power distribution systems
Large commercial and infrastructure facilities
Power distribution centers
Electrical systems requiring coordinated overload and short-circuit protection
The final selection should be based on the system voltage, rated current, fault level, and protection coordination requirements.
Advantages – Reliable Circuit Protection and System Integration
High-current application: The MasterPact NW family is designed for demanding power distribution systems.
Overload protection: Compatible trip-unit configurations can provide protection against sustained overcurrent.
Short-circuit protection: The appropriate breaker configuration can interrupt fault currents within its specified breaking capacity.
Switchboard integration: The product family supports different installation arrangements, depending on the selected version.
Protection coordination: Trip settings can be selected to coordinate with other protective devices in the electrical network.
Maintenance support: Inspection and servicing can be planned according to the device configuration and manufacturer's maintenance instructions.
Technical FAQs – Operation, Protection and Maintenance
Q1: What is the primary function of the NW40N1?
It is intended for low-voltage power distribution and circuit protection. Its purpose is to help protect electrical circuits against overloads and short circuits when correctly configured.
Q2: What does the NW40 designation represent?
The NW40 designation is associated with the 4000 A frame range in the MasterPact NW family. The actual rated current must be confirmed against the complete product reference.
Q3: What does the N1 performance designation mean?
N1 identifies an interrupting-performance category. The applicable short-circuit breaking capacity depends on the rated operating voltage and the specific product configuration.
Q4: Does the NW40N1 provide overload protection?
The circuit breaker can provide overload protection when equipped with a compatible trip unit and correctly configured protection settings.
Q5: Can it interrupt short-circuit currents?
Yes, provided the selected configuration has a breaking capacity suitable for the prospective fault current at the installation voltage.
Q6: What should be considered when choosing a trip unit?
Check the required current rating, protection functions, adjustable settings, system voltage, and coordination requirements. The trip unit must be compatible with the breaker.
Q7: Is the NW40N1 suitable for fixed or drawout installation?
MasterPact NW products are available in different mounting arrangements. Confirm whether the specific unit is fixed or drawout before selecting accessories or planning installation.
Q8: Can auxiliary contacts and remote-control accessories be used?
Compatible accessories are available for applicable MasterPact NW configurations. Their suitability depends on the breaker version and operating mechanism.
Q9: What maintenance is recommended?
Follow the manufacturer's maintenance schedule. Typical checks include inspecting electrical connections, contact condition, operating mechanisms, trip-unit functions, and auxiliary circuits.
Q10: What information is needed when replacing an existing NW circuit breaker?
Verify the complete catalog number, rated current, voltage, breaking capacity, pole configuration, mounting arrangement, terminal connections, trip unit, and accessories. A similar frame designation alone does not guarantee compatibility.