Brand:Honeywell DCS Item No.:2108B0272 Product Origin:USA Product Dimensions:190 x 40 x 80 mm Product Weight:0.5 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Honeywell 2108B0272 Optima Plus Calibration Cap is an original accessory designed for calibration work on the Searchpoint Optima Plus infrared point gas detector. It provides a dedicated interface for applying calibration gas to the detector's measurement chamber, helping technicians carry out controlled calibration procedures.
In fixed gas detection installations, regular calibration is essential for maintaining confidence in detector readings. The calibration cap supports this maintenance process by providing a suitable gas application arrangement for the Searchpoint Optima Plus.
During installation, the detector's weather protection must be removed while the dust barrier remains in place. Once calibration is complete, the cap must be removed so that the detector can return to normal gas monitoring conditions. This temporary-use requirement is important for maintaining proper detector operation.
Technical Specifications
Parameter
Specification
Brand
Honeywell Analytics
Model
2108B0272
Product Type
Optima Plus Calibration Cap
Compatible Equipment
Searchpoint Optima Plus Gas Detector
Product Category
Gas Detector Calibration Accessory
Function
Calibration Gas Application
Dimensions
190 × 40 × 80 mm
Weight
0.5 kg / 1.10 lb
Note: This accessory is intended for temporary calibration use. Follow the Searchpoint Optima Plus operating instructions for installation, calibration, and removal.
Recommended Related Models
The following accessories are associated with the Searchpoint Optima Plus gas detector and may be relevant when maintaining its calibration and gas-sampling arrangement.
Model
Product Type
Application
2108D0258
Optima Plus Gassing Cover
Applies gas during field functional checks
2108B0259
Dust Barrier
Helps protect the detector optics from dust and oil mist
2108B0276
Standard Weather Protection
Provides environmental protection for the detector
2108B0282
Optima Plus Flow Housing
Supports compatible flow-through gas sampling arrangements
Popular Related Models
These Honeywell products are also relevant to Searchpoint Optima Plus installation, commissioning, and maintenance work.
Model
Product Type
Application
Searchpoint Optima Plus
Infrared Point Gas Detector
Fixed-point gas detection
04230-A-1001
SHC1 Handheld Interrogator
Configuration and maintenance of compatible Honeywell gas detectors
2104B6250
SHC Calibrator Connector System
Connection accessory for compatible SHC calibration equipment
Verify detector compatibility and accessory configuration before ordering. The 2108B0272 calibration cap and 2108D0258 gassing cover serve different purposes and should be selected according to the intended procedure.
Applications
The Honeywell 2108B0272 Optima Plus Calibration Cap is a dedicated calibration accessory for the Searchpoint Optima Plus infrared gas detector. It provides a controlled interface for introducing calibration gas to the detector's measurement chamber, supporting accurate calibration procedures and routine maintenance.
Designed for use by qualified gas detection technicians, this accessory is particularly useful when verifying or adjusting detector performance during scheduled servicing.
Typical applications include:
Infrared gas detector calibration: Provides the required interface for applying calibration gas to Searchpoint Optima Plus.
Zero-point calibration: Supports procedures for establishing the detector's baseline response using the specified zero gas.
Span calibration: Allows calibration gas of a known concentration to be introduced during detector calibration.
Maintenance operations: Supports routine inspection and calibration of fixed gas detection installations.
Industrial safety systems: Helps maintain the calibration of gas detectors used in process plants, chemical facilities, and other industrial environments.
Key Features and Calibration Benefits
The 2108B0272 is designed specifically for the Searchpoint Optima Plus detector, providing a dedicated accessory for calibration work.
Dedicated detector compatibility: Designed for the Honeywell Searchpoint Optima Plus infrared gas detector.
Controlled gas application: Provides inlet and outlet connections for the calibration gas arrangement.
Calibration accuracy support: Helps establish the required gas exposure conditions during calibration procedures.
Maintenance convenience: Supports planned calibration and servicing without requiring a permanent modification to the detector.
Reusable accessory: Can be used for repeated calibration operations when properly maintained.
Purpose-built design: Provides a detector-specific interface rather than relying on an improvised gas application arrangement.
Important: The calibration cap is intended for temporary use. It must be removed after calibration so that ambient gas can reach the detector's measurement chamber normally.
Technical FAQs
Q1: What is the main function of the Honeywell 2108B0272?
The 2108B0272 is a calibration cap used to introduce calibration gas to the Searchpoint Optima Plus infrared gas detector during calibration procedures.
Q2: Which gas detector is compatible with this calibration cap?
It is designed for the Honeywell Searchpoint Optima Plus point infrared gas detector. Compatibility with other detector models should not be assumed.
Q3: What is the difference between a calibration cap and a gassing cover?
The calibration cap is intended for accurate detector calibration. The gassing cover is designed for applying gas during field functional checks. For calibration, Honeywell specifies using the dedicated calibration cap.
Q4: What detector protection components must be removed before fitting the cap?
The weather protection components must be removed, with the dust barrier remaining in place. Follow the detector's applicable operating instructions before fitting the accessory.
Q5: Does the calibration cap have gas inlet and outlet connections?
Yes. The accessory has designated inlet and outlet connections to support the calibration gas arrangement.
Q6: Can the calibration cap remain installed after calibration?
No. It must be removed after use. Leaving it fitted can prevent ambient gas from reaching the detector's measurement chamber and interfere with normal gas detection.
Q7: Can the 2108B0272 be used for routine detector maintenance?
Yes. It is intended for calibration procedures performed as part of scheduled inspection and maintenance of compatible Searchpoint Optima Plus installations.
Q8: Does the calibration cap perform gas measurement?
No. It is a mechanical calibration accessory. Gas detection and measurement are performed by the Searchpoint Optima Plus detector.
Q9: What should be checked before using the calibration cap?
Confirm the detector model, inspect the cap and its connections, check the calibration gas arrangement, and follow the manufacturer's calibration procedure. Ensure the detector is configured for the intended calibration operation.
Q10: What should be done if the detector does not respond correctly during calibration?
Check the calibration gas concentration and supply, gas connections, cap installation, detector condition, and calibration procedure. If the problem remains, follow the manufacturer's troubleshooting instructions before returning the detector to service.