Brand:Allen Bradley PLC Item No.:1747-C13 Product Origin:USA Product Dimensions:Cable Length: 3 feet Product Weight:Shipping Weight: 3 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Allen Bradley 1747-C13 SLC 500 Communication Cable is a dedicated connection accessory for compatible Allen Bradley SLC 500 automation systems. It is designed to connect specialty modules, including BASIC and KE modules, to the 1747-AIC Isolated Link Coupler.
The cable supports communication within a DH-485 network, making it relevant to legacy PLC installations that rely on this communication architecture. Its 3-foot (0.91 m) length is suitable for connections between nearby control components.
An important technical distinction is that the 1747-C13 carries communication signals only; it does not provide 24 VDC power to the 1747-AIC. The power connection must be arranged separately using the appropriate cable or external power source specified for the installation.
For maintenance and replacement projects, selecting the correct cable is essential because SLC 500 accessories such as the 1747-C10, 1747-C11, and 1747-C13 serve different connection purposes. Checking the module catalog numbers and wiring arrangement before installation helps prevent communication problems and incorrect connections.
Technical Specifications
Parameter
Specification
Brand
Allen Bradley
Model
1747-C13
Product Series
SLC 500
Product Type
Communication Cable
Communication Network
DH-485
Cable Length
3 ft (0.91 m)
Primary Application
Specialty Module to Isolated Link Coupler
Compatible Components
1747-AIC, compatible BASIC and KE modules
Power Transmission
Communication only; does not carry 24 VDC
Shipping Weight
3 kg / 6.61 lb
Lifecycle Status
Discontinued
Recommended Related Models
The following components are relevant to SLC 500 communication and interface applications:
Model
Product Description
1747-AIC
SLC 500 Isolated Link Coupler
1747-UIC
USB to DH-485 Interface Converter
1747-KE
DH-485/RS-232C Interface Module
1747-C10
SLC 500 Programming/Communication Cable
1747-C11
Processor-to-Isolated Link Coupler Cable
1747-BAS
SLC 500 BASIC Module
These products serve different roles in the communication system. Verify the intended connection and cable requirements before selecting a replacement.
Popular Related Models
Other Allen Bradley components commonly used in SLC 500 automation systems include:
1747 Series: SLC 500 processors, communication interfaces, and specialty modules.
1746 Series: Digital and analog I/O modules for SLC 500 controllers.
1747-AIC: Isolated Link Coupler for connecting compatible devices to a DH-485 network.
1747-UIC: USB interface converter for communication with compatible DH-485 equipment.
The 1747-C13 was discontinued by Rockwell Automation effective September 30, 2024. When sourcing this legacy component, verify the complete catalog number, connector condition, and compatibility with the target SLC 500 communication configuration.
Applications
The Allen Bradley 1747-C13 Communication Cable is designed for communication connections within compatible SLC 500 control systems. It is primarily used to connect a BASIC or KE specialty module to a 1747-AIC Isolated Link Coupler, supporting communication over a DH-485 network.
Typical applications include:
DH-485 Network Communication: Establishes a communication connection between compatible SLC 500 modules and network interface equipment.
BASIC Module Connectivity: Connects an SLC 500 BASIC or BASIC-T module to a 1747-AIC Isolated Link Coupler.
KE Module Communication: Supports communication connections involving compatible 1747-KE interface modules.
PLC Maintenance: Provides a replacement cable for servicing existing SLC 500 communication installations.
Legacy Automation Systems: Helps maintain communication infrastructure in facilities operating older Allen Bradley PLC equipment.
Key Features and Advantages
Dedicated SLC 500 Compatibility: Designed for specific communication arrangements within the Allen Bradley SLC 500 platform.
DH-485 Communication Support: Provides the physical communication link required for compatible specialty modules and isolated link couplers.
Compact Cable Length: The 3-foot (0.91 m) length is suitable for connections between nearby modules and communication interfaces.
Communication-Only Function: Carries communication signals rather than supplying 24 VDC power to the isolated link coupler.
Convenient Replacement: Offers a catalog-number-specific replacement option for maintaining existing SLC 500 installations.
Technical FAQs
Q1: What is the primary function of the 1747-C13?
A: It provides a communication connection between compatible SLC 500 specialty modules, such as BASIC or KE modules, and a 1747-AIC Isolated Link Coupler.
Q2: What communication network is supported?
A: The cable is used in DH-485 communication arrangements within compatible SLC 500 systems.
Q3: What is the cable length?
A: The specified cable length is 3 feet, approximately 0.91 meters.
Q4: Does the 1747-C13 supply 24 VDC power to the 1747-AIC?
A: No. The 1747-C13 functions as a communication link and does not carry 24 VDC power. A separate appropriate power connection is required.
Q5: Can the 1747-C13 connect a BASIC module to a 1747-AIC?
A: Yes. This is one of its documented applications in an SLC 500 system.
Q6: Is the 1747-C13 interchangeable with the 1747-C10?
A: No. The 1747-C13 provides the communication connection, while the 1747-C10 is used for a different processor-to-peripheral connection and can supply power to the isolated link coupler in the relevant arrangement.
Q7: What is the difference between the 1747-C13 and 1747-C11?
A: The 1747-C13 is a specialty-module-to-isolated-link-coupler communication cable. The 1747-C11 is a processor-to-isolated-link-coupler replacement cable. Their connection functions differ.
Q8: Can the 1747-C13 be used with a 1747-UIC interface?
A: The cable is listed for compatible 1747-UIC communication arrangements. Confirm the port connection and intended network configuration before installation.
Q9: What should be checked if communication fails?
A: Inspect the cable and connectors, verify the correct port connections, check the 1747-AIC power supply, and confirm that the DH-485 network configuration is correct.
Q10: Can a standard Ethernet patch cable replace the 1747-C13?
A: No. Similar connector shapes do not guarantee compatible wiring or electrical characteristics. Use the specified cable or a verified equivalent.