Allen Bradley 1492-IFM40F-FS24-2 40-Point Isolated Fused Digital Interface Module

Allen Bradley 1492-IFM40F-FS24-2 40-Point Isolated Fused Digital Interface Module

0.0
Points

Brand:Allen Bradley PLC
Item No.:1492-IFM40F-FS24-2
Product Origin:USA
Product Dimensions:120 × 83 × 70.5 mm
Product Weight:0.346 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

Introduction

The Allen Bradley 1492-IFM40F-FS24-2 40-Point Isolated Fusible Digital Interface Module is designed for PLC wiring applications that require organized field connections and individual output circuit protection. As part of Rockwell Automation's Bulletin 1492 wiring system, it provides a convenient interface between compatible digital I/O modules and external industrial equipment.

The module combines 40 connection points, 5 × 20 mm fuse clips, 24V AC/DC blown-fuse indicators, and additional output terminals. Its isolated fusible design helps simplify circuit organization while allowing maintenance personnel to identify fuse-related problems more conveniently.

For industrial panel builders and automation engineers, the 1492-IFM40F-FS24-2 offers a practical solution for digital output wiring. Before installation, users should confirm the corresponding PLC I/O module, connector arrangement, prewired cable, and fuse requirements.

Technical Specifications

Parameter

Specification

Brand

Allen Bradley

Model

1492-IFM40F-FS24-2

Product Type

40-Point Isolated Fusible Digital Interface Module

Product Family

Bulletin 1492

Connection Points

40

Interface Style

Isolated Fusible

Fuse Type

5 × 20 mm

Blown-Fuse Indicator

24V AC/DC

Terminal Configuration

Extra Terminals for Outputs

Field-Side Terminals

Two per I/O Connection

Dimensions

120 × 83 × 70.5 mm

Weight

0.346 kg / 0.76 lb

Recommended Related Models

Model

Product Description

1492-IFM40F

40-Point Feed-Through Digital Interface Module

1492-IFM40F-FS-2

40-Point Isolated Fusible Digital Interface Module

1492-IFM40F-FS24-2

40-Point Isolated Fusible Digital Interface Module

1492-IFM40F-F24-2

40-Point Isolated Fusible Digital Interface Module

1492-IFM40F-FS24-4

40-Point Isolated Fusible Digital Interface Module

Popular Related Models

Model

Product Description

1492-IFM20F-F24A-2

20-Point Fusible Digital Interface Module

1492-IFM20F

20-Point Feed-Through Digital Interface Module

1756-A7K

ControlLogix Chassis

1756-OF4K

ControlLogix Analog Output Module

1756-EN4TRK

ControlLogix EtherNet/IP Communication Module

2711P-T15C22D8S

PanelView Plus 7 Operator Terminal

2711P-T9W22D8S

PanelView Plus 7 Operator Terminal


Applications

The Allen Bradley 1492-IFM40F-FS24-2 is a 40-point isolated fusible digital interface module designed to simplify field wiring between PLC digital I/O modules and industrial equipment. It belongs to the Bulletin 1492 wiring system and provides organized terminal connections, individual fuse protection, and blown-fuse indication for output circuits.

Typical applications include:

  • PLC output wiring: Connect compatible digital output modules to field devices through an organized interface.

  • Industrial control panels: Simplify wiring arrangements for multiple output circuits.

  • Circuit protection: Provide individual fuse holders for connected output circuits.

  • Equipment control: Support connections to industrial actuators, relays, and other control devices.

  • Automation system integration: Facilitate wiring between PLC modules and field-side equipment.


Advantages

40-Point Interface Design

The module provides 40 connection points, making it suitable for applications involving multiple digital I/O circuits.

Isolated Fusible Configuration

Its isolated circuit arrangement and individual fuse holders help organize and protect connected output circuits.

Integrated Fuse Monitoring

The 24V AC/DC blown-fuse indicators provide visual assistance when identifying fuse-related faults.

Additional Output Terminals

Extra output terminals offer greater flexibility for field wiring and circuit organization.

Standard Fuse Compatibility

The module accommodates 5 × 20 mm fuses, allowing users to select suitable fuse ratings according to their application requirements.

Organized Cabinet Wiring

As part of the Bulletin 1492 wiring system, it helps reduce individual wiring complexity and supports a cleaner control cabinet layout.


Technical FAQs

Q1: What is the main function of the 1492-IFM40F-FS24-2?

It provides a 40-point isolated fusible interface for connecting compatible PLC digital I/O modules with field wiring.

Q2: How many connection points does this module provide?

It provides 40 connection points for digital I/O applications.

Q3: What type of fuses does the module accommodate?

It uses 5 × 20 mm fuse clips. Appropriate fuse ratings must be selected according to the connected circuit requirements.

Q4: Does the module include blown-fuse indicators?

Yes. It provides 24V AC/DC blown-fuse indication for output circuits.

Q5: What is the purpose of the extra output terminals?

They provide additional connection points for output-side wiring, helping simplify field circuit arrangements.

Q6: Are the output circuits isolated?

The module features an isolated interface arrangement. Refer to the wiring diagram to confirm the specific isolation configuration for the intended application.

Q7: Can this module connect directly to any PLC digital output card?

No. Compatibility depends on the I/O module's connector configuration, point count, electrical characteristics, and the appropriate prewired cable.

Q8: What should be checked when a blown-fuse indicator activates?

Inspect the corresponding fuse and connected load, check for short circuits or excessive current, and replace the fuse only after identifying the cause.

Q9: Are the fuses included with the module?

The module provides fuse clips, but the required fuses should be selected and purchased separately.

Q10: What should be verified before commissioning?

Check PLC compatibility, terminal assignments, fuse ratings, field wiring, supply voltage, and the operating condition of connected output devices.