Allen Bradley PLC

  1. Home
  2. Products
  3. Allen Bradley PLC
  4. Allen Bradley 440R-H23180 Guardmaster Minotaur MSR230P Safety Relay
Allen Bradley 440R-H23180 Guardmaster Minotaur MSR230P Safety Relay

Allen Bradley 440R-H23180 Guardmaster Minotaur MSR230P Safety Relay

0.0
Points

Brand:Allen Bradley PLC
Item No.:440R-H23180
Product Origin:USA
Product Dimensions:114.5 x 22.5 x 99 mm
Product Weight:0.215 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

Introduction

The Allen Bradley 440R-H23180 Guardmaster Minotaur MSR230P Safety Relay is designed for safety-related control applications in industrial machinery. It provides a relay-based monitoring solution for machine safety circuits, helping coordinate the response of connected control equipment when monitored safety conditions change.

Safety relays play an important role in industrial automation by providing dedicated logic for specific protective functions. In production environments, emergency stops and protective interlocks must operate as intended to help prevent hazardous machine movement or access during unsafe conditions. A suitable safety relay supports these functions as part of a complete safety architecture.

The 440R-H23180 is particularly relevant to maintenance and replacement projects involving existing Allen Bradley Guardmaster Minotaur equipment. Before purchasing, verify the complete catalog number, supply requirements, terminal arrangement, input configuration, and output characteristics. Correct selection is essential because safety relays with similar appearances may have different operating functions.

We provide industrial automation components for equipment maintenance, machine safety repairs, and control-system support. Contact us with your required model and quantity to confirm availability and request a quotation.

Technical Specifications

Parameter

Specification

Brand

Allen Bradley

Product Family

Guardmaster Minotaur

Model

440R-H23180

Product Type

MSR230P Safety Relay

Dimensions

114.5 × 22.5 × 99 mm

Weight

0.215 kg / 0.47 lb

Verify the rated supply voltage, safety input configuration, output contact arrangement, response characteristics, and applicable safety ratings using the product label and technical documentation.

Recommended Related Models

The following Allen Bradley Guardmaster components may be relevant to industrial safety control applications. Their functions and electrical characteristics are not necessarily interchangeable.

Model

Product Description

440R-B23020

Guardmaster Minotaur MSR5T Safety Monitoring Relay

440R-S12R2

Guardmaster Safety Relay

440R-S13R2

Guardmaster Safety Relay

440C-CR30-22BBB

Guardmaster Configurable Safety Relay

Popular Related Models

Other Allen Bradley machine safety products that may be considered for related control and protection systems include:

Model

Product Description

440G-LZ

Guardmaster Guard Locking Switch

440K-T

TLS-Z Guard Locking Switch

440K-E

Guardmaster Safety Interlock Switch

440R-S13R2

Guardmaster Safety Relay

440C-CR30-22BBB

Guardmaster Configurable Safety Relay

When selecting a replacement, compare the full catalog number and confirm that the electrical specifications and safety functions match the installed system. Complete the required safety validation and functional testing before putting the machine back into operation.


Applications

The Allen Bradley 440R-H23180 Guardmaster Minotaur MSR230P Safety Relay is an industrial safety control component designed to monitor safety circuits and support the safe operation of machinery. It is used in applications where emergency-stop devices, protective interlocks, and other safety-related inputs must be monitored before machine operation is permitted.

Typical applications include:

  • Monitoring emergency-stop circuits on automated machinery.

  • Supporting safety interlock arrangements for machine access doors.

  • Integrating protective devices into industrial control panels.

  • Managing safety-related shutdown functions on production equipment.

  • Supporting machinery protection systems in manufacturing and processing facilities.

The MSR230P is intended for integration into a properly designed machine safety circuit. Its application should be evaluated according to the required safety function, electrical configuration, and operating conditions.


Advantages

Dedicated Safety Circuit Monitoring

The relay provides a dedicated component for monitoring safety-related signals, helping ensure that machine operation depends on the required safety conditions being satisfied.

Industrial Guardmaster Design

As part of the Allen Bradley Guardmaster Minotaur range, the MSR230P is intended for industrial machine safety applications.

Support for Emergency-Stop Systems

Safety monitoring relays can form part of emergency-stop arrangements, allowing the machine control circuit to respond when an emergency-stop device is activated.

Integration with Protective Interlocks

The relay can be incorporated into suitable guard-monitoring and protective-device circuits, subject to its specific input and output requirements.

Practical Replacement for Existing Installations

For maintenance teams supporting established Minotaur safety systems, selecting the correct 440R-H23180 model helps reduce compatibility risks during equipment replacement.


Technical FAQs

Q1: What is the main function of the Allen Bradley 440R-H23180?

The 440R-H23180 is a Guardmaster Minotaur MSR230P safety relay used in industrial safety circuits to monitor safety-related inputs and control associated safety outputs.

Q2: What does the MSR230P designation identify?

MSR230P identifies the specific Minotaur safety relay model within the Guardmaster product range. Its detailed electrical and functional characteristics should be checked against the corresponding product documentation.

Q3: Can the 440R-H23180 be used in emergency-stop applications?

It may be suitable for an emergency-stop circuit when the relay's specifications and safety characteristics meet the requirements of the machine safety design.

Q4: Can it monitor machine guard interlocks?

Safety monitoring relays may be used with compatible guard interlock devices. Confirm the supported input configuration and wiring method before connecting a particular switch.

Q5: What happens when an emergency-stop device is activated?

When the monitored safety circuit changes to an unsafe state, the relay responds according to its internal safety logic and output arrangement. The connected machine control system should then perform the intended safe response.

Q6: Why might the safety relay fail to energize?

Potential causes include an incorrect supply connection, an open safety input circuit, an activated emergency-stop device, wiring errors, or a fault in the connected safety equipment.

Q7: What should be inspected if the relay cannot be reset?

Check the condition of the emergency-stop devices, guard switches, reset circuit, terminal connections, and input wiring. Any inspection or testing should be performed by qualified personnel.

Q8: Does the 440R-H23180 require external reset wiring?

The reset arrangement depends on the relay's specified operating mode and the machine safety circuit. Follow the manufacturer's wiring instructions rather than assuming a particular reset configuration.

Q9: Can another Guardmaster safety relay replace the MSR230P?

A different Guardmaster model should not be treated as a direct replacement without checking supply voltage, input logic, output contacts, timing functions, and safety ratings.

Q10: What tests should be completed after replacing the relay?

Verify the supply, safety input response, reset behavior, output switching, and machine stopping function. Document the functional test results before returning the equipment to service.


Look forward to your comments!Comment