GE Fanuc PLC

  1. Home
  2. Products
  3. GE Fanuc PLC
  4. GE IC660BBA106 115 VAC/125 VDC 6-Channel Current-Source Analog Input Block for Genius I/O Systems
GE IC660BBA106 115 VAC/125 VDC 6-Channel Current-Source Analog Input Block for Genius I/O Systems

GE IC660BBA106 115 VAC/125 VDC 6-Channel Current-Source Analog Input Block for Genius I/O Systems

0.0
Points

Brand:GE Fanuc PLC
Item No.:GE IC660BBA106
Product Origin: USA
Product Dimensions:224 × 90 × 112 mm
Product Weight:1.8 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

IC660BBA106 5IC660BBA106-1IC660BBA106-2IC660BBA106-3

The GE IC660BBA106 is a 6-channel current-source analog input block crafted for GE Fanuc’s Genius I/O distributed control architecture. Purpose-built to interface directly with standard industrial 4–20 mA current loop devices, this module delivers high-resolution acquisition with configurable conversion timing and robust diagnostics. Powered from either 115 VAC or 125 VDC, it’s optimal for process automation, remote I/O expansion, and analog signal monitoring in harsh industrial environments.


Technical Specifications

SpecificationDescription
Module TypeCurrent-Source Analog Input Block
ModelIC660BBA106
Power Supply115 VAC / 125 VDC nominal; operating range 93–132 VAC / 105–145 VDC
Analog Inputs6 isolated current inputs
Supported Signal4–20 mA (0–25 mA overrange)
Resolution1 µA
Input Accuracy±0.1 % full-scale
Input Impedance~100 Ω
Update/Conversion TimeUser-selectable 16.6 ms to 400 ms
Isolation1500 V RMS channel-to-channel
Status LEDs“Unit OK” & “I/O Enabled”
Heat Dissipation~12 W
CommunicationGenius Bus - distributed I/O protocol
Dimensions (H × W × D)224 × 90 × 112 mm (approx. from 8.83″ × 3.56″ × 4.42″)
Weight~1.8 kg (4 lbs)
Operating Temperature0 °C – 60 °C
Humidity5 % – 95 % non-condensing

Recommended Related Models

ModelFunctional Description
IC660BBA100115 VAC/125 VDC Analog I/O block (4 inputs + 2 outputs)
IC660BBA101115 VAC/125 VDC RTD temperature input block
IC660BBA103115 VAC/125 VDC thermocouple input block
IC660BBA104115 VAC/125 VDC mixed current input/output block

Popular GE Genius I/O Components

CategoryRepresentative Models
Genius ControllersIC660CPU001, IC660CPU002
Analog Input BlocksIC660BBA100, IC660BBA103
Digital I/O BlocksIC660BBD020, IC660BBD024
Bus DriversIC660EBD024


Applications

The IC660BBA106 is ideally deployed wherever accurate current-loop signal acquisition is critical:

  • Process automation monitoring (flow, level, pressure)

  • Factory data acquisition systems with 4–20 mA sensors

  • Distributed remote I/O expansion in large PLC installations

  • Environmental control & HVAC feedback loops

  • Legacy systems migration or retrofit automation requiring robust analog inputs

The block’s high input resolution and configurable conversion timing allow it to balance noise immunity and responsiveness in dynamic process environments.


Advantages

  • High-resolution current measurement: 1 µA granularity for precise analog acquisition

  • Dual power flexibility: Supports both AC and DC industrial supplies

  • Individually isolated channels: Strong 1500 V channel-to-channel isolation enhances safety and reduces noise effects

  • Configurable conversion timing: Selectable 16.6 ms–400 ms to optimize signal quality

  • Advanced diagnostics: Built-in overrange, underrange, alarm, and open-wire detection

  • Genius Bus compatibility: Smooth integration within Genius distributed I/O networks for modular system design 


Technical FAQs

  1. How many analog inputs does the IC660BBA106 provide?
    It offers 6 independently isolated current inputs for 4–20 mA signals.

  2. What power supplies can this block use?
    It runs from 115 VAC or 125 VDC with wide operating voltage ranges.

  3. What is the input resolution?
    Resolution is approximately 1 µA, enabling fine signal detail.

  4. Does it have built-in diagnostics?
    Yes — diagnostics include underrange/overrange, high/low alarms, and open-wire detection.

  5. Is channel isolation provided?
    Yes — each channel is isolated up to 1500 V RMS.

  6. What conversion times are supported?
    User-selectable between 16.6 ms and 400 ms.

  7. Where should power connect?
    Power connects to dedicated module terminals along with field inputs.

  8. What operating temperature range is supported?
    0 °C to 60 °C typical industrial range.

  9. Can it be used with different PLC generations?
    Yes — compatible with Genius Bus controllers across Series 90-30 and similar GE PLC platforms.

  10. What is the significance of the user-selectable conversion time?
    Longer conversion times improve measurement resolution and noise rejection; shorter times enhance scan speed. 