GE Fanuc PLC

  1. Home
  2. Products
  3. GE Fanuc PLC
  4. GE IC660TBA021 RTD Input Terminal Base Assembly for Genius I/O Field Connections
GE IC660TBA021 RTD Input Terminal Base Assembly for Genius I/O Field Connections

GE IC660TBA021 RTD Input Terminal Base Assembly for Genius I/O Field Connections

0.0
Points

Brand:GE Fanuc PLC
Item No.:GE IC660TBA021
Product Origin:USA
Product Dimensions:224 × 90 × 100 mm
Product Weight:0.85 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

GE IC660TBA021-2GE IC660TBA021-4IC660TBA021-2IC660TBA021

The GE IC660TBA021 is a Terminal Base Assembly specifically designed to support RTD (Resistance Temperature Detector) input blocks within the GE Fanuc Genius I/O distributed automation platform. Serving as the field wiring interface for RTD sensors, this terminal base provides a secure and organized connection point between field cabling and the corresponding RTD electronics assembly.

Developed for industrial environments, the IC660TBA021 simplifies field wiring, improves signal integrity, and enables reliable temperature measurement when paired with the matching electronics assembly.


Technical Specifications


SpecificationDescription
ModelGE IC660TBA021
Module TypeTerminal Base Assembly – RTD Input
Compatible SystemGE Fanuc Genius I/O
Wiring FunctionField RTD sensor connection
Supported SensorRTD (e.g., Pt100 / Pt1000 – depends on electronics assembly)
Terminal TypeScrew-clamp field terminals
Connection PointsMultiple discrete terminals for sensor wiring
Interface to ElectronicsEdge connector to RTD electronics assembly
MountingPlug-in to Genius I/O rack / block
Dimensions (W × H × D)224 × 90 × 100 mm
Weight0.85 kg (approx.)
Environmental RatingIndustrial, non-condensing
Operating Temperature0 to 60 °C
Storage Temperature−40 to 100 °C

Role in Genius I/O RTD Temperature Measurement


The IC660TBA021 provides the physical interface for RTD sensor leads and routes those signals safely to the associated electronics assembly (e.g., IC660EBA021). By separating the sensor wiring from the electronic circuitry, the terminal base:

  • Reduces noise and connection faults

  • Enables easier field terminations

  • Supports stable, high-quality analog signal capture

This architecture improves maintainability and minimizes downtime during installation and servicing.


Recommended Related Models


To complete an RTD input measurement block, the following Genius components are typically paired with the IC660TBA021:

  • GE IC660EBA021 – RTD Input Electronics Assembly

  • GE IC660BBA021 – Complete RTD input block assembly

  • GE IC660BCM501 / BCM101 – Genius bus controllers

  • GE IC660BBS100-series – Power supply modules

This combination delivers reliable temperature sensing integrated with a distributed control network.


Popular Allen-Bradley Analog Input Comparisons


When comparing across automation platforms, similar discrete terminal interface functionality is found in:

  • Allen-Bradley 1734-TB – POINT I/O terminal base assemblies

  • Allen-Bradley 1794-TB – FLEX I/O terminal base

  • Allen-Bradley 1769-TB – Compact I/O terminal base

These terminal bases serve analogous roles as wiring interfaces for analog input signals in Allen-Bradley distributed I/O systems.


Applications


The GE IC660TBA021 is specifically used in:

  • RTD temperature sensor field wiring

  • Distributed temperature acquisition panels

  • Environmental and process monitoring systems

  • Batch and continuous process control applications

  • Industrial machinery temperature feedback loops

Its use improves the clarity and reliability of RTD measurements in complex control systems.


Advantages


  • Provides a dedicated and secure interface for RTD sensor wiring

  • Organizes field connections for easier installation and maintenance

  • Separates field wiring from electronics to enhance signal quality

  • Compatible with standard Genius I/O racks and blocks

  • Modular design supports fast replacement and serviceability

  • Lightweight and built for industrial temperature and humidity ranges

These features make IC660TBA021 an essential component in RTD-based control and monitoring applications.


Technical FAQs


What is the GE IC660TBA021 used for?
It serves as the field connection interface for RTD temperature sensors in Genius I/O systems.

Which sensors does it support?
RTD sensors such as platinum or similar resistive temperature devices, with exact type supported defined by the paired electronics assembly.

Does it include electronics?
No, this module provides terminal connections only; the paired electronics assembly handles signal conversion.

How is it installed?
It plugs into the Genius I/O rack or output block and mates directly with the corresponding electronics assembly.

Can it be serviced without rewiring?
Yes, the modular design allows the electronics assembly to be swapped independently from field terminations.

Is LED indication included?
No, the terminal base itself does not include status LEDs; that is provided on the paired electronics assembly.

Is field wiring protected?
Field wiring is routed through robust screw-clamp terminals designed for industrial environments.

What temperatures is it designed for?
Operating temperatures from 0 to 60 °C and storage down to −40 °C.

Does it offer electrical isolation?
The terminal base does not provide isolation on its own; isolation characteristics derive from the paired electronics assembly.

Why use a dedicated terminal base?
A terminal base simplifies field wiring, improves signal integrity, and enhances maintainability compared to direct sensor-to-electronics connections.


Look forward to your comments!Comment
Latest comments
Tags:
Need Assistance? Chat with Us on WhatsApp!
Need Assistance? Click to Inquire
Back to top