GE Fanuc PLC

  1. Home
  2. Products
  3. GE Fanuc PLC
  4. GE IC660TBA024 Analog I/O Terminal Base Assembly for 4-Input / 2-Output Field Signal Connection in Genius I/O Systems
GE IC660TBA024 Analog I/O Terminal Base Assembly for 4-Input / 2-Output Field Signal Connection in Genius I/O Systems

GE IC660TBA024 Analog I/O Terminal Base Assembly for 4-Input / 2-Output Field Signal Connection in Genius I/O Systems

0.0
Points

Brand:GE Fanuc PLC
Item No.:GE IC660TBA024
Product Origin:USA
Product Dimensions:224 × 90 × 100 mm
Product Weight:0.95 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

IC660TBA024-7IC660TBA024-8IC660TBA024-5IC660TBA024-6

The GE IC660TBA024 is a Terminal Base Assembly designed for use within GE Fanuc Genius I/O distributed control systems. It provides a secure and organized interface between field wiring and the corresponding analog I/O electronics assembly, supporting four analog inputs and two analog outputs in a single module.

By serving as the physical connection point for sensors and actuators, this terminal base simplifies wiring, enhances signal integrity, and enables reliable analog data flow between field devices and the control network.


Technical Specifications


SpecificationDetails
ModelGE IC660TBA024
Module CategoryAnalog I/O Terminal Base Assembly
Supported SystemGE Fanuc Genius I/O
Wiring FunctionField-side connection for analog signal loops
Input/Output Configuration4 analog inputs + 2 analog outputs
Terminal TypeScrew-clamp field terminals
Interface to ElectronicsEdge connector for analog electronics assembly
MountingPlug-in Genius I/O rack / block mounting
Dimensions (W × H × D)224 × 90 × 100 mm
Weight0.95 kg (approx.)
Operating Temperature0 to 60 °C
Storage Temperature−40 to 100 °C
Environmental RatingIndustrial, non-condensing

Function and Field Wiring Role


The IC660TBA024 serves as the field wiring interface in a Genius analog I/O station. Field device leads — such as 4–20 mA current loops or voltage sensors — are terminated on the screw-clamp terminals. From there, the signals are routed through the terminal base into the corresponding analog output/input electronics assembly.

This separation of wiring and electronics allows for:

  • Cleaner installation and easier troubleshooting

  • Enhanced signal integrity by reducing noise and connection issues

  • Faster electronics replacement without touching field terminations


Recommended Related Models


To form a complete and robust analog I/O block, the IC660TBA024 is typically combined with:

  • GE IC660EBA024 – Analog I/O electronics assembly (4 inputs, 2 outputs)

  • GE IC660BBA024 – Complete analog I/O block kit

  • GE IC660BCM501 / BCM101 – Genius bus controller modules

  • GE IC660BBS100 / BBS101 / BBS102 / BBS103 – Power supply modules

Together, these components create a scalable and maintainable analog I/O solution.


Popular Allen-Bradley Terminal Base Comparisons


In multi-platform environments, similar terminal interface functionality is found in:

  • Allen-Bradley 1734-TB – POINT I/O terminal base

  • Allen-Bradley 5069-TB – Compact 5000 terminal base

  • Allen-Bradley 1794-TB – FLEX I/O terminal base

These terminal bases provide field connection points for analog and discrete I/O wiring in Allen-Bradley distributed systems.


Applications


The GE IC660TBA024 is used wherever analog signals need to be connected to a Genius I/O node, including:

  • Process control systems with mixed analog loops

  • Factory automation with multiple sensor/actuator interfaces

  • Environmental monitoring panels

  • Remote I/O installations on factory floors

  • Instrumentation hubs linking analog sensors to controllers

Its organization and secure terminations support reliable signal acquisition and distribution.


Advantages


  • Integrates 4 analog inputs and 2 analog outputs in a compact base

  • Screw-clamp terminals provide secure and vibration-resistant field connections

  • Modular design separates wiring from electronics for fast servicing

  • Compatible with Genius I/O architecture for distributed automation

  • Industrial-ready build tolerates factory conditions and non-condensing humidity

  • Application flexibility from simple loops to complex multi-signal panels

These advantages simplify installation, improve maintainability, and reduce potential wiring errors.


Technical FAQs


What is the GE IC660TBA024 used for?
It serves as the field wiring interface for a 4-input / 2-output analog block in Genius I/O systems.

What types of signals does it support?
Analog voltage and current signals, depending on the associated electronics assembly.

Can I replace the electronics without rewiring?
Yes, the modular design allows electronics replacement while field wiring at the terminal base remains intact.

Is the terminal base insulated?
The base organizes wiring but electrical isolation is provided by the paired electronics assembly.

What is the operating temperature range?
0 to 60 °C, with industrial non-condensing humidity tolerance.

How are field wires terminated?
Using screw-clamp terminals that secure wires mechanically and electrically.

Does it support remote or local installation?
Yes, it can be used in both centralized cabinets and remote I/O panels.

Is a separate enclosure required?
Depending on application requirements; many installations mount the base within a protective cabinet.

What controllers can it interface with?
Genius I/O systems, via compatible bus controllers like IC660BCM501 / BCM101.

Why use a terminal base?
It simplifies field wiring, enhances signal integrity, and isolates wiring from electronics.


Look forward to your comments!Comment