Yokogawa Electric

  1. Home
  2. Products
  3. Yokogawa Electric
  4. Yokogawa AAI141-H00 Analog Input Module
Yokogawa AAI141-H00 Analog Input Module

Yokogawa AAI141-H00 Analog Input Module

0.0
Points

Brand:Yokogawa Electric
Item No.:AAI141-H00
Product Origin:Japan
Product Dimensions:107.5 × 32.8 × 130 mm
Product Weight:0.2 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

Introduction

The Yokogawa AAI141-H00 Analog Input Module is designed to deliver reliable and accurate analog signal acquisition in industrial automation systems. Its 16-channel configuration provides high-density measurement capability in a compact footprint. With robust construction and low-noise design, this module ensures dependable operation in demanding process environments. Ideal for integrating multiple analog signals into Yokogawa DCS systems, the AAI141-H00 supports real-time process control and enhances overall plant efficiency.


Technical Specifications

ItemDescription
Product NameAnalog Input Module
ModelAAI141-H00
Module TypeAnalog Input
Input Signal4–20 mA current, 0–10 V voltage
Channels16
CompatibilityYokogawa DCS systems
IsolationChannel-to-channel and channel-to-ground isolation
Response TimeSuitable for real-time process control
CalibrationFactory calibrated, minimal adjustment required
Dimensions107.5 x 32.8 x 130 mm
Weight0.2 kg
MountingRack or DIN rail compatible
EnvironmentIndustrial process control environments

Recommended Related Models

ModelDescription
AAI143High-density analog input module
AAI144Temperature input module
AAI120Voltage/current input module
AAI130Multipurpose analog input module
AAD141Analog output module
AAE141Analog expansion module
AAI141Standard analog input module
AAI145Extended signal range input module
AAI150Redundant analog input module
AAI141-EXExplosion-proof analog input module

Popular Related Models

ModelDescription
AAI143-01High-precision multi-channel input module
AAI144-01Temperature measurement analog input
AAI120-01Standard voltage/current input module
AAD141-01Analog output interface module
AAE141-01Analog expansion module for large racks
AAI145-01Extended range analog input module
AAI141-02Compact analog input for dense racks
AAI130-01Multipurpose analog signal input
AAI150-01Redundant analog input module
AAI141-EX-01Explosion-proof analog input for hazardous areas


Applications

The Yokogawa AAI141-H00 Analog Input Module delivers precise and stable analog signal acquisition for advanced industrial control systems. Its high channel density makes it ideal for:

  • Capturing temperature, pressure, flow, and level signals in chemical, petrochemical, and oil & gas plants

  • Integration with Yokogawa DCS for real-time process monitoring

  • High-density analog input racks requiring compact, reliable modules

  • Continuous industrial operations demanding accurate and uninterrupted data logging

  • Process automation where multiple analog signals must be monitored simultaneously

Engineered for performance and reliability, the AAI141-H00 ensures that critical process data is captured with precision.


Advantages

  • 16 high-precision analog channels for monitoring multiple signals concurrently

  • Compact design to maximize space efficiency in control system racks

  • Seamless Yokogawa DCS integration, supporting large-scale automation requirements

  • Superior signal integrity with low noise and minimal interference

  • Front-access installation, simplifying module replacement and maintenance

  • Supports both voltage and current inputs, providing flexibility in process signal types

  • Robust industrial-grade construction, resistant to vibration and EMI

  • Reliable long-term operation, reducing the need for frequent calibration


FAQs

1. How many analog input channels are on the AAI141-H00 module?
It has 16 channels, allowing simultaneous monitoring of multiple process signals.

2. What types of signals are supported?
It supports 4–20 mA current signals and 0–10 V voltage signals.

3. Can it handle differential inputs?
Yes, it can accept both single-ended and differential analog signals.

4. Is the module hot-swappable?
No, the system should be powered down before installation or removal.

5. How is signal noise minimized?
High-quality filtering and isolation circuits reduce electrical interference and maintain signal fidelity.

6. What is the typical response time?
The module provides rapid signal acquisition suitable for real-time control and monitoring.

7. How is the health of the module monitored?
The DCS system provides status and diagnostic feedback for all channels.

8. Can it operate in high-temperature industrial environments?
Yes, within the specified Yokogawa operating temperature range.

9. Is proper grounding required?
Yes, proper grounding ensures optimal EMI protection and signal stability.

10. Does it require calibration after installation?
No, the module is factory-calibrated; minimal adjustment may be required for custom ranges.