Yokogawa Electric

  1. Home
  2. Products
  3. Yokogawa Electric
  4. Yokogawa AAI141-S00/A4S00 Analog Input Module
Yokogawa AAI141-S00/A4S00 Analog Input Module

Yokogawa AAI141-S00/A4S00 Analog Input Module

0.0
Points

Brand:Yokogawa Electric
Item No.:AAI141-S00/A4S00
Product Origin:Japan
Product Dimensions:107.5 × 32.8 × 130 mm
Product Weight:0.2 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

Introduction

The Yokogawa AAI141-S00/A4S00 Analog Input Module delivers high-precision analog signal acquisition in a compact, 16-channel design. Built for seamless integration with Yokogawa DCS systems, it ensures stable and accurate operation even in demanding industrial environments. Ideal for high-density analog input applications, this module enhances real-time process control and operational efficiency while ensuring long-term reliability and minimal maintenance.


Technical Specifications

ItemDescription
Product NameAnalog Input Module
ModelAAI141-S00/A4S00
Module TypeAnalog Input
Input Signal4–20 mA current, 0–10 V voltage
Channels16
CompatibilityYokogawa DCS systems
IsolationChannel-to-channel and channel-to-ground isolation
Response TimeSuitable for real-time process control
CalibrationFactory calibrated, minimal adjustment required
Dimensions107.5 x 32.8 x 130 mm
Weight0.2 kg
MountingRack or DIN rail compatible
EnvironmentIndustrial process control environments

Recommended Related Models

ModelDescription
AAI141-S00Standard analog input module
AAI141-H00Base analog input module
AAI141-H00 S2Enhanced analog input module
AAI141-H50High-density analog input module
AAI141-H50/K4A00Advanced analog input module
AAI141-H53High-precision analog input module
AAI143High-density analog input module
AAI144Temperature input module
AAI120Voltage/current input module
AAD141Analog output module

Popular Related Models

ModelDescription
AAI143-01High-precision multi-channel input module
AAI144-01Temperature measurement analog input
AAI120-01Standard voltage/current input module
AAD141-01Analog output interface module
AAE141-01Analog expansion module for large racks
AAI145-01Extended range analog input module
AAI141-S00/A4S00Compact high-density analog input module
AAI130-01Multipurpose analog signal input
AAI150-01Redundant analog input module
AAI141-EX-01Explosion-proof analog input module


Applications

The Yokogawa AAI141-S00/A4S00 Analog Input Module is designed for robust, high-precision analog signal acquisition in industrial control systems. Its 16-channel configuration makes it ideal for:

  • Continuous monitoring of temperature, pressure, flow, and level signals in chemical, oil & gas, and petrochemical plants

  • Integration with Yokogawa DCS for automated process control and real-time data acquisition

  • High-density analog input racks in space-constrained environments

  • Industrial operations requiring low-noise, high-fidelity analog inputs

  • Automation systems that demand simultaneous measurement of multiple process variables

This module provides reliable signal capture, supporting process optimization and operational safety in demanding environments.


Advantages

  • 16 analog input channels, enabling simultaneous monitoring of multiple signals

  • High-accuracy signal acquisition, reducing measurement errors and improving process control

  • Compact and space-efficient design, suitable for high-density rack installations

  • Seamless integration with Yokogawa DCS, enhancing process automation capabilities

  • Front-accessible module, simplifying installation, inspection, and maintenance

  • Supports both 4–20 mA and 0–10 V input signals, offering process flexibility

  • Durable industrial-grade construction, resistant to EMI, vibration, and harsh environments

  • Reliable long-term operation, minimizing the need for frequent recalibration


FAQs

1. How many input channels does the AAI141-S00/A4S00 module have?
It has 16 analog input channels for comprehensive process monitoring.

2. What types of analog signals are supported?
It supports 4–20 mA current and 0–10 V voltage signals.

3. Can it accept differential input signals?
Yes, it supports both single-ended and differential input configurations.

4. Is the module hot-swappable?
No, the system must be powered down before installing or removing the module.

5. How is signal integrity maintained?
High-quality filtering, channel-to-channel isolation, and low-noise design ensure stable signal acquisition.

6. What is the typical response time?
The module provides fast, real-time signal acquisition suitable for process control.

7. Can it operate in harsh industrial environments?
Yes, it is designed to function reliably within the Yokogawa operating temperature and environmental range.

8. How is the module’s health monitored?
Diagnostics and status for each channel are available through the DCS system.

9. Is proper grounding required?
Yes, grounding ensures EMI protection and stable signal operation.

10. Does it require calibration after installation?
The module is factory-calibrated; minor adjustments may be made for custom signal ranges.


Look forward to your comments!Comment
Latest comments
Tags:
Need Assistance? Chat with Us on WhatsApp!
Need Assistance? Click to Inquire
Back to top