Yokogawa Electric

  1. Home
  2. Products
  3. Yokogawa Electric
  4. Yokogawa VI702 Vnet/IP Interface Card
Yokogawa VI702 Vnet/IP Interface Card

Yokogawa VI702 Vnet/IP Interface Card

0.0
Points

Brand:Yokogawa Electric
Item No.:VI702
Product Origin:Japan
Product Dimensions:180.97 x 21.59 x 126.31 mm
Product Weight:0.18 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

Introduction

The Yokogawa VI702 Vnet/IP Interface Card enables reliable, high-speed Ethernet communication for distributed control systems. Its compact and robust design, combined with seamless integration into Yokogawa DCS platforms, ensures stable network connectivity, accurate data transfer, and enhanced process monitoring and control for industrial applications.


Technical Specifications

ItemDescription
Product TypeInterface Card
Communication ProtocolVnet/IP (Ethernet-based)
System CompatibilityYokogawa DCS platforms
Installation MethodRack-mounted
Dimensions (H × W × D)180.97 × 21.59 × 126.31 mm
Weight0.18 kg

Recommended Related Models

ModelModule TypePrimary Function
Yokogawa VI702Interface CardVnet/IP connectivity
Yokogawa VI701Interface CardIndustrial Ethernet interface
Yokogawa NFLP121Communication ModulePROFIBUS-DP integration
Yokogawa ADV151Digital Input ModuleField signal monitoring
Yokogawa ADV551Digital Output ModuleDiscrete signal control
Yokogawa AAI143Analog Input ModuleHigh-density analog acquisition
Yokogawa ADO141Digital Output ModuleActuator and valve control
Yokogawa CP451CPU ModuleCore control processing
Yokogawa PW401Power Supply ModuleSystem power supply
Yokogawa AAI135Analog Input ModuleStandard analog input

Popular Related Models

ModelModule TypeTypical Application
Yokogawa VI702Interface CardHigh-speed Vnet/IP communication
Yokogawa VI701Interface CardEthernet field device interface
Yokogawa NFLP121Communication ModulePROFIBUS-DP integration
Yokogawa ADV151Digital Input ModuleDiscrete input monitoring
Yokogawa ADV551Digital Output ModuleDiscrete output control
Yokogawa AAI143Analog Input ModuleHigh-density analog acquisition
Yokogawa ADO141Digital Output ModuleActuator and valve control
Yokogawa CP451CPU ModuleControl processing
Yokogawa PW402Power Supply ModuleRedundant power solution
Yokogawa AAI135Analog Input ModuleStandard analog input


Applications

The Yokogawa VI702 Vnet/IP Interface Card is designed for distributed control systems that require fast, reliable, and secure Ethernet-based communication. It is commonly used in chemical plants, oil & gas facilities, power generation, and complex manufacturing operations. The module enables seamless integration of field devices and controllers over Vnet/IP, supporting real-time data exchange, monitoring, and automation for efficient and safe process control.


Advantages

The VI702 Interface Card offers high-speed, low-latency Vnet/IP communication with excellent noise immunity and industrial reliability. Its slim design allows for efficient integration into rack-mounted systems, while full compatibility with Yokogawa DCS platforms simplifies configuration and reduces commissioning time. The module supports continuous 24/7 operation, ensures robust network connectivity, and improves overall system responsiveness and visibility.


FAQs

1. What network protocol does the VI702 support?
It supports Vnet/IP, a high-speed Ethernet-based communication protocol for industrial automation.

2. Can it connect multiple controllers and field devices?
Yes, the module allows integration of multiple Vnet/IP-enabled devices within the same network.

3. How does it handle network errors or packet loss?
It provides error detection, retransmission, and diagnostic feedback to maintain reliable communication.

4. Is it compatible with other Yokogawa DCS modules?
Yes, it integrates seamlessly with Yokogawa DCS systems for monitoring and control.

5. What is the maximum data transfer rate?
The VI702 supports standard Vnet/IP speeds, ensuring fast and reliable data exchange.

6. Can it operate in electrically noisy industrial environments?
Yes, it is designed for industrial conditions with strong immunity to electrical interference.

7. How is the module configured and monitored?
Configuration and monitoring are performed through Yokogawa engineering software integrated with the DCS platform.

8. Does it provide network diagnostics?
Yes, it offers status monitoring, error reporting, and network diagnostics to assist troubleshooting.

9. Can it maintain operation during minor power fluctuations?
Yes, it is designed to handle minor power disturbances and resumes normal operation afterward.

10. Is firmware update possible without stopping the system?
Yes, firmware updates can typically be applied with minimal operational impact depending on system configuration.


Look forward to your comments!Comment
Latest comments
Tags:
Need Assistance? Chat with Us on WhatsApp!
Need Assistance? Click to Inquire
Back to top