Brand:Ingersoll Rand
Item No.:47555208001 47552954001
Product Origin:USA
Product Dimensions:202 × 21 × 261 mm
Product Weight:0.30 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

24509184-324509184-124509184-424509184-2

Introduction

The Ingersoll Rand 47555208001 47552954001 Air-Cooled Preventive Maintenance Kit combination covers the temperature-control portion of the 8,000-hour major-service program for compatible R90–110 I compressors. 47555208001 is the overall air-cooled preventive-maintenance package, while 47552954001 is the dedicated temperature-sensing valve maintenance kit listed within that service configuration.

Temperature management is a critical part of rotary screw compressor operation. Compressor lubricant absorbs and transfers heat during compression, so the thermal-control system must maintain the lubricant within an appropriate operating range across varying loads and ambient conditions.

The 47552954001 reference is specifically described in the parts catalog as a Temperature control valve maintenance kit and is associated with R90–160 compressor configurations. This distinguishes it from a complete cooler assembly, a water-cooler seal kit, or a standalone temperature sensor.

The relationship between the requested references is directly documented in the R90–110 I maintenance table. The 8,000-hour air-cooled package lists the 23429822 air filter, 23424922 coolant filter, 23545841 separator, 23497001 pre-filter, 23531577 minimum-pressure-valve kit, 47552954001 temperature-sensing valve kit, 47553880001 inlet-valve kit, and 39218193 motor grease.

This makes 47555208001 a comprehensive major-service package rather than a filter-only maintenance kit. Temperature control is serviced alongside filtration, air/oil separation, pressure control, inlet control, and motor lubrication.

A temperature-control valve can experience contamination, seal deterioration, mechanical wear, or changes in its operating characteristics over extended service periods. A dedicated maintenance kit allows the applicable service components to be renewed during planned maintenance without assuming that the entire temperature-control assembly must be replaced.

Abnormal lubricant temperature should not automatically be attributed to the valve. Restricted cooler passages, cooler fouling, incorrect lubricant level, temperature-sensor faults, control-system problems, ambient conditions, or other flow restrictions can produce similar symptoms. A complete thermal-system diagnosis is therefore appropriate when temperature behavior is abnormal.

During service, technicians should inspect the valve body, internal components, seals, connections, temperature-sensing/control elements, and nearby coolant or lubricant passages according to the applicable Ingersoll Rand procedure.

The exact internal contents of 47552954001 should not be inferred solely from the kit name. Maintenance kits can contain configuration-specific seals, valve components, springs, or related service items. The current compressor-specific bill of materials should determine the actual contents.

The application range is also important. Parts data lists 47552954001 across multiple R90–160 configurations. Different compressor revisions or thermal-management arrangements can require different service components even within the same nominal machine family.

For maintenance planning, 47555208001 should be distinguished from the corresponding 8,000-hour water-cooled package 47555465001. The air-cooled and water-cooled packages share some recurring service components but differ in cooling-system requirements.

For purchasing teams, retaining both references in the service record improves traceability: 47555208001 identifies the major 8,000-hour air-cooled service event, while 47552954001 identifies the temperature-control valve service requirement.

A proper replacement process should include verification of the compressor identification, cooling configuration, valve arrangement, sealing interfaces, and current service procedure. After installation, the temperature-control system should be checked for correct operating behavior before the compressor returns to normal production.

The exact valve dimensions, temperature setpoint, spring characteristics, internal kit contents, package dimensions, weight, and complete serial-number application range were not sufficiently verified from authoritative documentation. These values are therefore intentionally not estimated.

For industrial compressor operators and service professionals, 47555208001 and 47552954001 provide a clear reference for temperature-control service within the 8,000-hour air-cooled R90–110 maintenance program. Correct configuration matching and careful valve servicing can help maintain stable lubricant temperature and dependable compressor operation.


Technical Specifications

SpecificationDetails
BrandIngersoll Rand
Major Maintenance Kit Reference47555208001
Temperature-Control Kit Reference47552954001
47555208001 Product Type8,000-Hour Air-Cooled Preventive Maintenance Kit
47552954001 Product TypeTemperature Control / Temperature-Sensing Valve Maintenance Kit
Documented Major-Kit ApplicationR90–110 I
Broader Temperature-Kit ApplicationR90–160 configurations
Published Quantity in Major Kit1
Primary SystemCompressor lubricant temperature-control system
Primary FunctionTemperature regulation and valve maintenance
Cooling ConfigurationAir-cooled for 47555208001
Valve TypeTemperature-control / temperature-sensing valve
Temperature SetpointApplication-specific; verify OEM documentation
Internal Kit ContentsVerify current configuration-specific bill of materials
Seal ComponentsVerify current kit bill of materials
Valve DimensionsApplication-specific; verify current parts documentation
Service Interval8,000 hours for 47555208001
InstallationFollow applicable Ingersoll Rand service documentation
CompatibilityConfirm compressor model, serial number, cooling configuration, and current parts documentation

The published R90–110 I service table directly associates one 47552954001 temperature-sensing valve kit with the 47555208001 8,000-hour air-cooled package.


Recommended Companion Models

ModelProduct Name
23424922Coolant Filter Element
23545841Separator Tank Element
23531577Minimum-Pressure Valve Service Kit
47553880001Intake Valve Service Kit 8K

These components are part of the broader R90–110 I 8,000-hour air-cooled maintenance configuration and address fluid filtration, air/oil separation, pressure control, and inlet-air control.


Frequently Selected Alternatives

ModelProduct Name
475554650018,000-Hour Water-Cooled Preventive Maintenance Kit
47555464001Water-Cooler Seal Maintenance Kit
47553881001Intake Valve Service Kit 8K with Modification
47553880001Intake Valve Service Kit 8K


Where It Excels in Industrial Use

  • 8,000-Hour Air-Cooled Maintenance: 47555208001 is identified as the 8,000-hour air-cooled preventive-maintenance kit for the Ingersoll Rand R90–110 I configuration. The published service table includes 47552954001 as the temperature-sensing valve maintenance kit.
  • Temperature-Control Service: 47552954001 is identified as an Ingersoll Rand Temperature-Sensing Valve Maintenance Kit for applicable R90–160 configurations.
  • Lubricant Temperature Regulation: The temperature-sensing/control valve participates in regulating compressor lubricant temperature through the applicable thermal-management circuit.
  • Major Preventive Maintenance: The 8,000-hour package combines temperature-control service with air filtration, coolant filtration, air/oil separation, minimum-pressure-valve service, inlet-valve service, and motor lubrication.
  • Configuration-Controlled Fitment: 47552954001 is listed across multiple R90–160 configurations, so compressor model, serial number, cooling arrangement, and current parts documentation should be verified before ordering.


Key Strengths at a Glance

  • Dedicated 8,000-Hour Air-Cooled Package: 47555208001 is specifically listed as an 8,000-hour air-cooled preventive-maintenance package for R90–110 I equipment.
  • Direct Temperature-Valve Association: The R90–110 I service table lists one 47552954001 temperature-sensing valve kit under 47555208001.
  • Dedicated Valve-Service Reference: 47552954001 is cataloged as a temperature-control valve maintenance kit rather than a complete compressor cooler or an individual temperature sensor.
  • Thermal-Management Support: Proper temperature-control valve operation helps maintain the intended compressor lubricant temperature and supports stable operating conditions.
  • Maintenance Traceability: Keeping 47555208001 with 47552954001 links the major 8,000-hour service event with its specific temperature-control maintenance requirement.



Technical FAQs

1. What is Ingersoll Rand 47555208001?

47555208001 is identified as an 8,000-hour air-cooled preventive-maintenance kit for the R90–110 I compressor configuration.

2. What is Ingersoll Rand 47552954001?

47552954001 is an Ingersoll Rand temperature-sensing/control valve maintenance kit used on applicable R90–160 compressor configurations.

3. What does the temperature-control valve do?

It helps regulate compressor lubricant temperature by controlling the appropriate thermal-management path within the compressor's cooling circuit.

4. Is 47552954001 an individual temperature sensor?

No. The available parts data identifies it as a temperature-control/temperature-sensing valve maintenance kit, not simply a standalone sensor.

5. Is 47552954001 associated with 47555208001?

Yes. The R90–110 I 8,000-hour air-cooled service listing specifies one 47552954001 temperature-sensing valve kit within 47555208001.

6. Is 47552954001 included in every 47555208001 kit?

The published service data confirms the pairing and quantity for the R90–110 I configuration. The current machine-specific bill of materials should remain the final confirmation for a particular compressor revision.

7. What problems can a deteriorating temperature-control valve cause?

Possible symptoms include abnormal lubricant temperature, unstable thermal behavior, inadequate cooling, excessive cooling, or related compressor alarms. These symptoms can also originate from the cooler, sensor, control circuit, lubricant condition, or other components.

8. Why is temperature control important in a rotary screw compressor?

The compressor lubricant performs important lubrication and heat-transfer functions. Maintaining its temperature within the intended operating range supports reliable lubrication and thermal performance.

9. Can 47552954001 be replaced with a generic thermostatic valve kit?

Not automatically. Valve geometry, temperature characteristics, connection configuration, sealing components, and compressor application must match the intended installation.

10. How should compatibility be verified?

Confirm the compressor model and serial number, installed temperature-control valve configuration, cooling arrangement, current parts list, and applicable Ingersoll Rand service documentation before ordering.