Points

Brand:Ingersoll Rand
Item No.:47572170001 47555464001
Product Origin:USA
Product Dimensions:110 × 66.8 × 50 mm
Product Weight:0.30 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

24509200-124509200-224509200-324509200-4

Introduction

Ingersoll Rand 47572170001 is an 8000-hour preventive maintenance kit, while 47555464001 is a water cooler seal maintenance kit for applicable water-cooled compressor configurations.

A water-cooled compressor depends on reliable heat transfer to control operating temperatures. The water cooler provides the thermal interface between the compressor's operating fluids and the cooling-water circuit, while seals maintain the integrity of the fluid boundaries within the assembly.

Seal condition becomes increasingly important as equipment accumulates operating hours. Thermal cycling, pressure changes, and long-term exposure to operating fluids can gradually affect sealing materials. Replacing the appropriate seals during planned maintenance helps preserve cooling-system integrity and reduces the possibility of leakage or cross-contamination.

For facilities where compressor availability directly supports production, incorporating water cooler seal service into an extended maintenance program provides a practical reliability advantage.


Technical Specifications

SpecificationDetails
BrandIngersoll Rand
Preventive Maintenance Kit47572170001
Water Cooler Seal Kit47555464001
Product Type8000-Hour Preventive Maintenance Kit and Water Cooler Seal Maintenance Kit
Maintenance Interval8000 Hours
Cooling ConfigurationWater-Cooled
Component TypeWater Cooler Seal Maintenance Kit
Primary FunctionCooler Sealing
Main Performance RoleFluid-Circuit Separation
Secondary FunctionLeak Prevention
ApplicationIndustrial Water-Cooled Rotary Screw Compressor
Kit DimensionsNot specified in the available product data
WeightNot specified in the available product data

Recommended Companion Models

ModelProduct Name
23424922Coolant Oil Filter Element
23523772Intake Pre-Filter Pad
23545841Air/Oil Separator Element
39218193High-Temperature Motor Grease

Frequently Selected Alternatives

ModelProduct Name
47552954001Temperature Control Valve Maintenance Kit
47553880001Inlet Valve Maintenance Kit
99289894Minimum Pressure Valve Repair Kit
47553881001Inlet Valve Maintenance Kit


Where It Excels in Industrial Use

  • Extended-Interval Compressor Maintenance
    47572170001 supports 8000-hour preventive maintenance for applicable Ingersoll Rand compressor systems, helping maintenance teams organize major service work around established operating intervals.
  • Water Cooler Sealing Service
    47555464001 is a water cooler seal maintenance kit designed for applicable Ingersoll Rand water-cooled compressor configurations.
  • Cooling-System Reliability
    Maintaining the cooler sealing components helps preserve the separation between cooling-water and compressor-fluid circuits.
  • Leak Prevention
    Properly maintained seals help reduce the risk of coolant leakage, lubricant contamination, and loss of cooling-system integrity.
  • Industrial Continuous-Duty Operation
    Particularly valuable for production facilities and process-air installations where dependable water-cooled compressor performance is essential.


Key Strengths at a Glance

  • 8000-Hour Service Integration
    47572170001 provides a structured long-interval maintenance solution for applicable Ingersoll Rand compressor systems.
  • Dedicated Cooler Seal Kit
    47555464001 provides application-focused sealing components for water cooler maintenance.
  • Cooling-Circuit Protection
    Correct sealing helps maintain the integrity of the compressor heat-exchange system.
  • Fluid Separation
    Proper seals help prevent unwanted interaction between cooling water and compressor lubricant.
  • Leak-Control Support
    Replacing aging seals during scheduled maintenance can reduce the likelihood of coolant or lubricant leakage.
  • Preventive Reliability Advantage
    Cooler seal service during a planned shutdown can help avoid unplanned cooling-system repairs and production interruptions.


Technical FAQs

1. What is Ingersoll Rand 47572170001 used for?

47572170001 is an 8000-hour preventive maintenance kit associated with applicable Ingersoll Rand compressor configurations.

2. What is Ingersoll Rand 47555464001?

47555464001 is a water cooler seal maintenance kit used for applicable Ingersoll Rand water-cooled compressor systems.

3. What is the function of the water cooler in a compressor?

The water cooler transfers heat from the compressor's operating fluids to the cooling-water circuit, helping maintain appropriate operating temperatures.

4. Why are cooler seals important?

Seals maintain separation between fluid circuits and prevent leakage at cooler interfaces. A compromised seal can affect cooling performance and fluid integrity.

5. What can cause water cooler seals to deteriorate?

Thermal cycling, pressure fluctuations, aging, chemical exposure, improper installation, and extended operating service can contribute to seal deterioration.

6. What problems can result from a damaged cooler seal?

A damaged seal can cause coolant leakage, lubricant leakage, loss of cooling performance, or unwanted mixing between cooling water and compressor fluid.

7. Can existing cooler seals simply be reused after cooler service?

Reuse should not be assumed. Seals can deform, harden, or lose their sealing characteristics after prolonged service. The applicable maintenance procedure should determine whether replacement is required.

8. What should be inspected during cooler seal replacement?

The cooler mating surfaces, seal grooves, fasteners, fluid connections, cooler passages, and surrounding components should be checked for corrosion, deposits, damage, and contamination.

9. Why is fluid contamination a concern in a water-cooled compressor?

Cross-contamination between cooling water and compressor lubricant can affect fluid properties, cooling performance, corrosion protection, and component reliability.

10. How should 47555464001 compatibility be verified?

Confirm the compressor model, serial number, water-cooler configuration, existing seal-kit identification, and applicable Ingersoll Rand parts information before ordering or installation.


Look forward to your comments!Comment
Latest comments
Tags:
Need Assistance? Chat with Us on WhatsApp!
Need Assistance? Click to Inquire
Back to top