Brand:Siemens Item No.:6SN1161-1CA00-0BA1 Product Origin:Germany Product Dimensions:64 × 49 × 76 mm Product Weight:0.084 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Siemens 6SN1161-1CA00-0BA1 Drive Bus Cable is a model-specific connectivity component intended for a compatible Siemens drive-system installation. In industrial automation, reliable connections are important for maintaining communication between equipment components and supporting consistent system operation.
When sourcing a replacement, maintenance engineers and purchasing teams should verify the full order number against the original cable and the relevant equipment documentation. Components with similar part numbers may have different connector configurations or technical requirements, so compatibility should not be inferred from appearance alone.
A reliable procurement process should confirm the cable's condition, connector details, and intended application. For critical industrial equipment, these checks can help reduce installation errors and avoid unnecessary downtime caused by incompatible spare parts.
During installation, follow the manufacturer's instructions for connection, cable routing, and troubleshooting. Correct identification and careful handling help maintain the integrity of the drive-system communication interface.
Technical Specifications
Parameter
Specification
Brand
Siemens
Model
6SN1161-1CA00-0BA1
Product Type
Drive Bus Cable
Product Category
Industrial Automation / Drive-System Connectivity
Dimensions
64 × 49 × 76 mm
Dimensions in Inches
2.52 × 1.93 × 2.99 in
Weight
0.084 kg (0.19 lb)
Communication Interface
Verify using the applicable Siemens documentation
Connector Configuration
Confirm before ordering
System Compatibility
Verify against the intended drive-system configuration
Product Condition
Confirm new, used, or refurbished status with the supplier
Note: Dimensions and weight are based on the supplied product information. Cable length, connector type, pin assignment, and interface specifications should be confirmed separately before installation.
Recommended Related Models
The following Siemens components may be relevant for industrial drive-system maintenance and spare-parts research. They should not be considered direct substitutes without technical verification.
Model
Product Type
Selection Consideration
Siemens 6SN1161-1CA00-0BA0
Drive Bus Cable
Compare connector and interface specifications
Siemens 6SN1161-1CA00-0BA1
Drive Bus Cable
Confirm the exact application and connection requirements
Siemens 6SN1145-1AA00-0AA0
Infeed Module
Verify its role in the drive-system configuration
Siemens 6SN1124-1AB00-0CA2
Power Supply Module
Check system compatibility and electrical requirements
Popular Related Models
Industrial buyers maintaining Siemens drive systems may also research the following components:
Siemens 6SN1161-1CA00-0BA0 — Drive Bus Cable
Siemens 6SN1161-1CA00-0BA1 — Drive Bus Cable
Siemens 6SN1145-1AA00-0AA0 — Infeed Module
Siemens 6SN1145-1AA00-0CA0 — Infeed Module
Siemens 6SN1124-1AB00-0CA2 — Power Supply Module
Before ordering, verify the complete order number, connector configuration, and intended interface against the applicable Siemens documentation. Similar part numbers do not guarantee direct interchangeability.
Applications
The Siemens 6SN1161-1CA00-0BA1 Drive Bus Cable is an industrial connectivity component identified for use in compatible Siemens drive-system applications. Reliable connections between drive components and control equipment are essential for maintaining communication and coordinated machine operation.
Depending on the documented interface and system configuration, compatible drive bus cables may be used in the following environments:
CNC machine tools: Supporting communication connections within compatible drive and machine-control installations.
Industrial automation systems: Connecting designated components in established Siemens drive architectures.
Manufacturing equipment: Supporting maintenance of communication links in automated production machinery.
Drive-system servicing: Replacing a damaged or missing cable with a verified matching part.
Before purchasing or installing this cable, confirm its exact interface, connector configuration, and supported equipment using the relevant Siemens documentation.
Advantages
1. Precise Model Identification
The complete order number, 6SN1161-1CA00-0BA1, helps distinguish this component from similar Siemens accessories. Accurate identification reduces the risk of ordering a cable with an incompatible connection or specification.
2. Support for Drive-System Connectivity
A correctly specified bus cable helps maintain the intended connection between compatible system components. Interface and wiring requirements should be confirmed before installation.
3. Compact Component Dimensions
The supplied dimensions make it easier for purchasing and maintenance teams to record the component's physical requirements. Connector clearance and installation space should still be checked against the actual equipment.
4. Convenient Replacement and Maintenance
A verified replacement cable can help restore a connection without unnecessary changes to the original wiring arrangement.
5. More Efficient Spare-Parts Management
Recording the full part number and its application helps maintenance departments organize inventory, identify replacements, and reduce procurement errors.
Technical FAQs
Q1: What is the Siemens 6SN1161-1CA00-0BA1 Drive Bus Cable used for?
It is identified as a Siemens drive bus cable for an industrial automation application. Its exact communication function and compatible equipment should be confirmed from the documentation for this specific part number.
Q2: How do I confirm whether this cable matches my drive system?
Check the complete order number, the required communication interface, connector type, pin assignment, and connected equipment against the system documentation.
Q3: Can the 6SN1161-1CA00-0BA1 replace the 6SN1161-1CA00-0BA0?
Do not assume that the two models are interchangeable. Compare their official specifications and approved applications before substituting one for the other.
Q4: Can a standard industrial cable be used instead?
Only if its electrical characteristics, connector arrangement, pin assignment, and communication requirements meet the equipment manufacturer's specifications. Physical fit alone does not establish compatibility.
Q5: What can cause communication problems after cable replacement?
Potential causes include an incorrect cable, improperly seated connectors, damaged contacts, incorrect wiring, or faults in connected devices. Check system diagnostics and follow the manufacturer's troubleshooting procedure.
Q6: How should the connectors be inspected?
Check for bent contacts, contamination, cracked housings, and signs of mechanical damage. Ensure connectors are correctly aligned and fully seated according to the installation instructions.
Q7: Does cable routing affect communication reliability?
Yes. Excessive bending, crushing, tension, and unsuitable routing near electrical interference sources may affect performance. Follow the manufacturer's cable-routing and electromagnetic compatibility guidelines.
Q8: Should the equipment be powered down before replacing the cable?
Follow the system-specific safety and service instructions. Isolate power where required, apply site lockout/tagout procedures, and ensure the work is performed by qualified personnel.
Q9: How can an intermittent bus connection be diagnosed?
Review diagnostic logs, inspect connectors and cable routing, and perform approved continuity or interface checks where applicable. Avoid disconnecting live connections unless the equipment documentation explicitly permits it.
Q10: What details should be recorded after replacement?
Record the part number, connected equipment, installation location, replacement date, and any diagnostic results. This information supports future maintenance and fault analysis.