Schneider PLC

  1. Home
  2. Products
  3. Schneider PLC
  4. Schneider MT06NA Breaker
Schneider MT06NA Breaker

Schneider MT06NA Breaker

0.0
Points

Brand:Schneider PLC
Item No.:MT06NA
Product Origin:France
Product Dimensions:301 x 196 x 276 mm
Product Weight:14 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart


Introduction: A Practical Choice for Industrial Circuit Protection

The Schneider MT06NA Circuit Breaker is a model to consider when sourcing electrical protection equipment for industrial distribution and power control applications. For procurement teams, panel builders, and industrial maintenance engineers, selecting the right breaker is essential to maintaining a dependable electrical installation and ensuring compatibility with the existing system.

In demanding industrial environments, circuit protection must be considered as part of a complete electrical design. Rated operating conditions, fault-current levels, connection arrangements, and coordination with other protective devices all influence the suitability of a particular breaker.

When purchasing the MT06NA, buyers should confirm the full nameplate designation and applicable technical specifications before ordering. This is especially important for replacement projects, where differences in breaker configuration or electrical ratings can affect installation compatibility.

For industrial spare-parts procurement, we recommend verifying the product identity, condition, and configuration before shipment. Accurate identification helps reduce purchasing errors and supports smoother maintenance planning.

Technical Specifications

The following table summarizes the product information currently available for the Schneider MT06NA Circuit Breaker. Electrical ratings should be confirmed against the exact product nameplate and manufacturer documentation.

Parameter

Specification

Brand

Schneider Electric

Model

MT06NA

Product Type

Circuit Breaker

Product Application

Industrial Electrical Distribution

Dimensions (W × H × D)

301 × 196 × 276 mm

Weight

14 kg (30.86 lb)

Rated Current

Confirm from product nameplate

Rated Operational Voltage

Confirm from product nameplate

Number of Poles

Confirm from product configuration

Short-Circuit Breaking Capacity

Confirm from the applicable technical documentation

Mounting Configuration

Verify before installation

Product Condition

Confirm at the time of purchase

Selection note: The dimensions and weight above are based on the supplied product information. They should not be treated as verified manufacturer specifications for every configuration sold under a similar model designation.

Recommended Related Models

The following Schneider Electric Masterpact MT models are worth considering when evaluating related circuit breakers. These are related model designations, not confirmed direct replacements for the MT06NA. Verify frame compatibility, electrical ratings, and mounting arrangements before substitution.

Model

Product Type

Selection Consideration

Schneider MT06N1

Circuit Breaker

Related MT06 frame designation

Schneider MT08N1

Circuit Breaker

Alternative frame rating to evaluate

Schneider MT10N1

Circuit Breaker

For applications requiring a different rated-current configuration

Schneider MT12N1

Circuit Breaker

Another MT-series option for technical comparison

Schneider MT16N1

Circuit Breaker

Higher frame-rating option to evaluate

Popular Related Models

These additional Schneider Electric Masterpact circuit breaker models may be relevant to industrial power distribution projects and replacement-part sourcing.

Model

Product Family

Typical Procurement Focus

Schneider MT06N1

Masterpact MT

Related breaker configuration

Schneider MT08N1

Masterpact MT

Alternative current-rating configuration

Schneider MT10N1

Masterpact MT

Distribution system requirements

Schneider MT12N1

Masterpact MT

Industrial switchgear applications

Schneider MT16N1

Masterpact MT

Higher frame-rating requirements

When comparing these models, check the complete catalog designation rather than relying on the frame number alone. Breaking capacity, trip-unit configuration, pole count, and fixed or drawout construction can vary and must be confirmed before ordering.

For dependable industrial procurement, provide the required model number and nameplate details when requesting a quotation. This helps ensure that the supplied Schneider Electric circuit breaker matches the intended electrical installation and maintenance requirements.


Applications

The Schneider MT06NA Circuit Breaker is intended for use in industrial electrical distribution systems where dependable circuit protection and reliable switching performance are essential. In manufacturing facilities, utility installations, and industrial control panels, circuit breakers play an important role in protecting electrical equipment and supporting safe power distribution.

Typical application areas include:

  • Industrial Power Distribution: Used in electrical distribution assemblies to support circuit protection and controlled power delivery.

  • Manufacturing Facilities: Suitable for integration into industrial electrical systems serving production equipment and auxiliary loads, subject to the installer's verification of ratings.

  • Control Panel Assemblies: Can be considered for electrical cabinets and distribution panels where the specified breaker configuration meets the system requirements.

  • Equipment Protection: Supports protection strategies designed to limit the effects of electrical faults when correctly selected and coordinated with the connected circuit.

  • Electrical Maintenance and Replacement: May be used as a replacement component when the complete model designation, electrical ratings, mounting arrangement, and compatibility with the existing assembly have been confirmed.

Selecting the correct breaker requires more than matching its model number. Engineers should verify the rated current, rated operational voltage, breaking capacity, trip characteristics, and installation requirements before placing the unit into service.


Advantages and Engineering Considerations

1. Designed for Industrial Distribution Systems

Circuit breakers are fundamental components in industrial power distribution. A correctly specified unit helps establish a coordinated protection arrangement for downstream circuits and connected equipment.

2. Supports System Protection Planning

Appropriate breaker selection allows engineers to coordinate overcurrent and short-circuit protection with the requirements of the electrical installation. Actual protection performance depends on the device's verified ratings and the overall system design.

3. Suitable for Equipment Integration

For panel builders and maintenance teams, compatibility with the existing switchgear assembly is a key consideration. Checking the mounting method, terminal arrangement, and accessory configuration before installation helps reduce commissioning problems.

4. Practical for Maintenance and Replacement Projects

Accurate model identification simplifies procurement and helps maintenance personnel compare replacement candidates against the original equipment specifications.

5. Supports Long-Term Equipment Management

Keeping clear records of the installed breaker model, electrical ratings, and maintenance history helps improve spare-parts planning and reduces the risk of ordering incompatible components.

6. Professional Procurement Support

When sourcing the Schneider MT06NA Circuit Breaker, buyers should request confirmation of the exact model designation, product condition, applicable technical documentation, and compatibility with the intended application. These checks help support a more reliable purchasing decision.


Technical FAQs

Q1. What is the primary function of the Schneider MT06NA Circuit Breaker?

Its intended role should be confirmed against the manufacturer's specifications for the exact model. In general, a circuit breaker protects an electrical circuit by interrupting current under specified fault or overload conditions.

Q2. How can I confirm the rated current of the MT06NA?

Check the device nameplate and the applicable technical documentation. Do not infer the rated current from the MT06NA model designation alone.

Q3. How should the breaking capacity be selected?

The breaker’s rated short-circuit breaking capacity must be appropriate for the prospective fault current at the installation point. The selection should follow applicable electrical codes and the manufacturer's published ratings.

Q4. Can this breaker be used in a three-phase electrical system?

Three-phase suitability depends on the breaker’s pole configuration, voltage rating, and intended application. Confirm these details before installation rather than assuming compatibility from the product name.

Q5. What is the difference between overload protection and short-circuit protection?

Overload protection responds to excessive current sustained over a period of time, while short-circuit protection addresses much higher fault currents that can develop rapidly. The available protection functions depend on the specific breaker design and trip unit.

Q6. Can the MT06NA directly replace another Schneider circuit breaker?

Not automatically. The replacement must match the required electrical ratings, breaking capacity, pole arrangement, mounting system, terminal configuration, and any relevant accessories.

Q7. What should be checked before energizing the breaker?

Qualified personnel should verify the wiring, terminal connections, protective settings where applicable, mechanical installation, insulation requirements, and coordination with upstream and downstream protective devices. Follow the manufacturer's installation instructions and local regulations.

Q8. Does the breaker require periodic maintenance?

Maintenance requirements depend on the specific product design and the operating environment. Inspection and testing should follow the manufacturer's instructions and the facility's electrical maintenance program.

Q9. What can cause a circuit breaker to trip repeatedly?

Possible causes include sustained overload, short circuits, ground faults, incorrect protection settings, or a problem with connected equipment. Investigate the underlying cause before resetting the breaker. Repeatedly resetting a breaker without diagnosis can create additional hazards.

Q10. What information should be supplied when requesting a replacement?

Provide the complete model designation, nameplate ratings, pole configuration, mounting and connection details, product photographs, and any relevant accessory or trip-unit information. This helps the supplier verify compatibility before shipment.


Look forward to your comments!Comment
Latest comments
Tags:
Need Assistance? Chat with Us on WhatsApp!
Need Assistance? Click to Inquire
Back to top