Brand:Siemens
Item No.:6AG1315-2FJ14-2AY0
Product Origin:Germany
Product Dimensions:40 × 125 × 130 mm
Product Weight:0.525 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart


Introduction

The Siemens 6AG1315-2FJ14-2AY0 SIPLUS S7-300 CPU 315F-2PN/DP is a fail-safe central processing unit developed for automation systems that require dependable control, network connectivity, and extended environmental protection. Based on the 6ES7315-2FJ14-0AB0, it combines 512 KB of work memory with MPI/PROFIBUS DP and Ethernet PROFINET communication.

A key feature of this version is its conformity with EN 50155, making it suitable for railway rolling-stock applications that require equipment designed around specific railway environmental standards. Its conformal coating and specified operating temperature range of -25 to +60°C provide additional protection for demanding installation conditions.

The integrated fail-safe functionality allows the CPU to support safety-related automation tasks alongside standard PLC operations when configured with the appropriate Siemens engineering tools and validated safety architecture. Its two-port PROFINET switch also simplifies connections within compatible industrial networks.

For system integrators, maintenance teams, and railway automation engineers, the 6AG1315-2FJ14-2AY0 is a specialized S7-300 controller option for applications where fail-safe processing, communication flexibility, and EN 50155 conformity are important selection criteria.

Technical Specifications

Parameter

Specification

Manufacturer

Siemens

Model

6AG1315-2FJ14-2AY0

Product Family

SIPLUS S7-300

CPU Designation

CPU 315F-2PN/DP

Product Type

Fail-Safe CPU Module

Base Model

6ES7315-2FJ14-0AB0

Railway Standard

EN 50155

Work Memory

512 KB

First Interface

MPI / PROFIBUS DP

PROFIBUS DP Speed

Up to 12 Mbps

Second Interface

Ethernet PROFINET

PROFINET Switch

Integrated 2-port switch

Memory Card

Micro Memory Card required

Engineering Software

STEP 7 V5.5 or higher

Safety Engineering

Distributed Safety V5.4 SP4

Supply Voltage

24 V DC

Permissible Supply Range

20.4–28.8 V DC

Conformal Coating

Yes

Operating Temperature

-25 to +60°C

Dimensions (W × H × D)

40 × 125 × 130 mm

Weight

0.525 kg / 1.16 lb

Recommended Related Models

The following Siemens CPUs are relevant alternatives for comparing fail-safe capabilities, communication interfaces, and railway application requirements.

Model

Product Description

6AG1315-2FJ14-2AB0

SIPLUS S7-300 CPU 315F-2PN/DP

6AG1315-6FF04-2AY0

SIPLUS S7-300 CPU 315F-2DP (EN 50155)

6AG1317-2FK14-2AY0

SIPLUS S7-300 CPU 317F-2PN/DP (EN 50155)

6AG1317-6FF04-2AY0

SIPLUS S7-300 CPU 317F-2DP (EN 50155)

6ES7315-2FJ14-0AB0

SIMATIC S7-300 CPU 315F-2PN/DP

Popular Related Models

For S7-300 system maintenance, expansion, and spare-part selection, these additional Siemens CPU models may also be worth considering:

  • Siemens 6AG1315-2AH14-2AY0 – SIPLUS S7-300 CPU 315-2DP (EN 50155)

  • Siemens 6AG1315-2EH14-2AY0 – SIPLUS S7-300 CPU 315-2PN/DP (EN 50155)

  • Siemens 6AG1317-2EK14-2AY0 – SIPLUS S7-300 CPU 317-2PN/DP (EN 50155)

  • Siemens 6AG1317-2FK14-2AB0 – SIPLUS S7-300 CPU 317F-2PN/DP

  • Siemens 6ES7315-2AH14-0AB0 – SIMATIC S7-300 CPU 315-2DP

  • Siemens 6ES7315-2EH14-0AB0 – SIMATIC S7-300 CPU 315-2PN/DP

  • Siemens 6ES7317-2FK14-0AB0 – SIMATIC S7-300 CPU 317F-2PN/DP


Applications

The Siemens 6AG1315-2FJ14-2AY0 is a SIPLUS S7-300 CPU 315F-2PN/DP designed for industrial automation systems that require fail-safe control and reliable communication between central controllers and distributed field devices. Based on the SIMATIC S7-300 platform, it combines standard PLC processing with safety-related control functions.

Its compliance with EN 50155 makes it particularly relevant to railway rolling-stock applications. The CPU can also be used in compatible industrial automation installations where extended environmental protection and fail-safe functionality are required.

Typical applications include:

  • Railway automation: Supports control systems used in rolling-stock applications requiring compliance with EN 50155.

  • Machine safety systems: Handles safety-related automation tasks in appropriately designed and validated control architectures.

  • Industrial production lines: Coordinates machine sequences, operating conditions, and equipment interlocks.

  • Distributed I/O networks: Connects remote I/O stations and field devices through PROFIBUS DP and PROFINET.

  • Material handling systems: Supports automated conveyors, transfer equipment, and coordinated machine operations.

  • Industrial equipment modernization: Provides a fail-safe CPU option for compatible S7-300 installations.


Advantages

1. Designed for Railway Applications

The 6AG1315-2FJ14-2AY0 is the EN 50155 version of the SIPLUS CPU 315F-2PN/DP. Its railway-related conformity makes it suitable for applications where rolling-stock environmental and equipment requirements must be considered.

2. Integrated Fail-Safe Functionality

The CPU supports both standard automation and safety-related control functions. This allows engineers to coordinate ordinary machine operations and configured safety tasks within one compatible S7-300 architecture.

3. PROFINET and PROFIBUS DP Connectivity

The module provides an MPI/DP interface and an Ethernet PROFINET interface with an integrated two-port switch. These interfaces support communication with compatible automation equipment and distributed devices.

4. 512 KB Work Memory

With 512 KB of work memory, the CPU provides resources for executing control programs and processing automation data in suitable S7-300 applications.

5. SIPLUS Environmental Protection

Conformal coating helps protect electronic components against environmental influences. The specified operating temperature range of -25 to +60°C provides additional flexibility for applications exposed to wider temperature variations.

6. Established Siemens Engineering Environment

The CPU is configured using Siemens STEP 7 engineering software, with Distributed Safety engineering tools required for its fail-safe functions. This supports integration into compatible S7-300 engineering and maintenance workflows.


Technical FAQs

Q1: What type of controller is the Siemens 6AG1315-2FJ14-2AY0?

It is a SIPLUS S7-300 CPU 315F-2PN/DP, a fail-safe programmable logic controller designed for standard and safety-related automation applications.

Q2: What does the 2AY0 suffix indicate?

The 2AY0 version is the EN 50155-compliant SIPLUS variant. It is intended for applications involving railway rolling-stock requirements and includes conformal coating.

Q3: What is the difference between the 6AG1315-2FJ14-2AY0 and 6AG1315-2FJ14-2AB0?

Both are SIPLUS CPU 315F-2PN/DP models based on the same standard Siemens CPU. The 2AY0 version is specified for EN 50155 railway applications, while the 2AB0 version does not carry that same EN 50155 designation.

Q4: How much work memory does this CPU provide?

The CPU has 512 KB of work memory for program execution and data processing.

Q5: Which communication interfaces are integrated into the module?

It provides an MPI/PROFIBUS DP interface with a transmission rate of up to 12 Mbps and an Ethernet PROFINET interface with an integrated two-port switch.

Q6: Does the CPU require a Micro Memory Card?

Yes. A compatible Siemens Micro Memory Card is required for operation and is used to store the user program and relevant configuration data.

Q7: Which software is required for programming?

The specified engineering environment includes STEP 7 V5.5 or higher. Distributed Safety V5.4 SP4 is specified for fail-safe engineering.

Q8: Can this CPU control remote I/O stations?

Yes. It supports distributed I/O communication through PROFIBUS DP and PROFINET. The remote devices must be compatible with the selected network and correctly configured in the engineering project.

Q9: What should be checked if the CPU cannot establish PROFINET communication?

Check the Ethernet connection, device power, PROFINET device name, IP configuration, network topology, and hardware configuration. Diagnostic information from the CPU and connected devices can help isolate the cause.

Q10: Can the 6AG1315-2FJ14-2AY0 replace the standard 6ES7315-2FJ14-0AB0?

The SIPLUS CPU is based on the 6ES7315-2FJ14-0AB0 platform, but replacement should not be treated as automatically interchangeable. Engineers should verify the application requirements, environmental conditions, hardware configuration, firmware compatibility, and safety program before installation.