ABB PST142-600-70 1SFA894010R7000 Soft Starter

ABB PST142-600-70 1SFA894010R7000 Soft Starter

0.0
Points

Brand:ABB PLC
Item No.:PST142-600-70
Product Origin:Sweden (SE)
Product Dimensions:390 x 186 x 270 mm
Product Weight:13 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart

Introduction

The ABB PST142-600-70 1SFA894010R7000 Soft Starter is engineered to provide reliable motor starting and stopping control in industrial automation environments. As part of ABB's PST series, it combines controlled voltage regulation, motor protection and flexible configuration to address the electrical and mechanical challenges associated with high-power motor applications.

Traditional direct-on-line motor starting can produce substantial inrush current and sudden mechanical torque. These effects may place additional stress on electrical distribution systems and connected machinery. The PST142-600-70 helps overcome these challenges by controlling the voltage supplied to the motor during acceleration and deceleration.

Its 142 A rated operational current makes it suitable for a range of industrial motor control applications. Adjustable starting parameters allow engineers to optimize motor acceleration according to the connected load, while soft stopping helps reduce abrupt changes in mechanical and hydraulic systems.

The PST platform also offers integrated monitoring and protection functions, supporting more effective equipment management and troubleshooting. With compatible communication accessories, the soft starter can be incorporated into industrial automation and motor management systems.

For manufacturing facilities, infrastructure projects and industrial maintenance teams, the ABB PST142-600-70 provides a practical solution for upgrading motor starting arrangements or replacing existing soft starter equipment.

By combining controlled motor operation, electrical protection and flexible integration capabilities, this ABB soft starter helps improve equipment reliability and support continuous industrial production.

Technical Specifications

Parameter

Specification

Brand

ABB

Model

PST142-600-70

ABB Part Number

1SFA894010R7000

Product Type

Soft Starter

Product Series

PST

Rated Operational Current

142 A

Rated Operational Voltage

208–600 V AC

Control Supply Voltage

100–250 V AC

Number of Phases

3

Compatible Motor Type

Three-Phase Asynchronous Motor

Starting Method

Controlled Voltage Ramp

Starting Functions

Soft Start / Current Limitation

Stopping Function

Soft Stop

Motor Protection

Electronic Motor Protection

Communication

Fieldbus Through Compatible Accessories

Application

Industrial Motor Starting and Control

Dimensions (H × W × D)

390 × 186 × 270 mm

Weight

13 kg / 28.66 lb

Recommended Related Models

The following ABB PST soft starters are relevant alternatives for industrial motor control projects. Selection should be based on motor current, supply voltage, starting frequency and load characteristics.

Model

ABB Part Number

Product Description

PST72-600-70

1SFA894008R7000

PST Soft Starter

PST85-600-70

1SFA894008R8000

PST Soft Starter

PST105-600-70

1SFA894009R7000

PST Soft Starter

PST142-600-70

1SFA894010R7000

PST Soft Starter

PST175-600-70

1SFA894011R7000

PST Soft Starter

Popular Related Models

For industrial motor control, equipment replacement and automation system maintenance, the following ABB soft starter models are also worth considering.

Model

Product Description

PST30-600-70

PST Soft Starter

PST37-600-70

PST Soft Starter

PST44-600-70

PST Soft Starter

PST60-600-70

PST Soft Starter

PST72-600-70

PST Soft Starter

PST85-600-70

PST Soft Starter

PST105-600-70

PST Soft Starter

PST142-600-70

PST Soft Starter

PST175-600-70

PST Soft Starter

The ABB PST142-600-70 is a suitable choice for industrial facilities requiring controlled starting of higher-current motors. Its combination of soft starting, stopping control and integrated protection makes it a valuable component for improving motor operation and maintaining dependable production processes.


Applications

The ABB PST142-600-70 Soft Starter is an advanced motor starting solution designed for industrial three-phase asynchronous motors. Belonging to ABB's PST soft starter family, it provides controlled acceleration and deceleration, helping reduce electrical inrush current and mechanical stress during motor operation.

With a rated operational current of 142 A and support for industrial motor control applications, the PST142-600-70 is suitable for facilities that require dependable starting performance, integrated motor protection and flexible system configuration.

Typical application areas include:

  • Water and Wastewater Treatment: Controls pump starting and stopping to help minimize hydraulic pressure fluctuations.

  • Oil and Gas Processing: Supports reliable operation of industrial pumps, compressors and auxiliary motor-driven equipment.

  • Mining and Mineral Processing: Helps reduce mechanical stress on conveyor systems, crushers and other heavy-duty machinery.

  • HVAC Installations: Provides controlled starting for large ventilation fans, blowers and industrial air-handling equipment.

  • Chemical Manufacturing: Supports smooth motor operation in mixing, pumping and process circulation systems.

  • Power Generation: Helps improve motor starting performance in auxiliary plant equipment.

  • General Manufacturing: Provides controlled motor starting for production machinery and automated industrial equipment.


Advantages

1. Controlled Motor Starting

The PST142-600-70 gradually increases the voltage supplied to the motor during startup. This reduces the electrical and mechanical impact associated with direct-on-line starting.

2. High-Current Motor Control Capability

With a rated operational current of 142 A, the unit is designed for industrial motor applications requiring a higher current capacity and reliable starting performance.

3. Adjustable Starting Characteristics

Configurable starting parameters allow engineers to adapt acceleration behavior to different motor and load requirements, helping achieve more consistent machine operation.

4. Smooth Motor Stopping

The soft stopping function gradually reduces motor voltage, making the unit particularly useful in pumping applications where abrupt stopping can cause pressure surges and water hammer.

5. Integrated Motor Protection

Electronic protection and monitoring functions help identify abnormal operating conditions, supporting motor safety and reducing the risk of unexpected equipment damage.

6. Flexible Industrial Integration

The PST series supports communication with compatible industrial automation systems through optional fieldbus accessories, allowing integration into centralized motor management environments.

7. Reduced Mechanical Wear

Controlled acceleration and deceleration help limit sudden torque changes, reducing unnecessary stress on couplings, belts, gearboxes and connected machinery.

8. Improved Maintenance Efficiency

Built-in monitoring and diagnostic capabilities help maintenance personnel identify operating abnormalities and investigate motor-related problems more efficiently.


Technical FAQs

Q1: What is the primary function of the ABB PST142-600-70?

The PST142-600-70 is designed to control the starting and stopping of three-phase asynchronous motors. It gradually adjusts the motor supply voltage to reduce starting current and mechanical stress.

Q2: What is the rated operational current of this soft starter?

The PST142-600-70 has a rated operational current of 142 A under the applicable manufacturer operating conditions. Actual motor selection must consider utilization category, supply voltage, starting duty and ambient temperature.

Q3: What supply voltage is supported by the PST142-600-70?

The model belongs to ABB's 600 V PST soft starter range, supporting operational voltages within its specified voltage range. The exact permissible voltage must be checked against the product nameplate and technical documentation.

Q4: Can the PST142-600-70 reduce motor inrush current?

Yes. It uses controlled voltage ramping and current limitation to reduce the high starting current associated with direct-on-line motor starting. The actual current reduction depends on the motor, load and selected parameters.

Q5: Does the PST142-600-70 support soft stopping?

Yes. The soft stopping function gradually reduces the motor supply voltage. It is particularly useful for centrifugal pumps and other applications where abrupt stopping can create mechanical or hydraulic disturbances.

Q6: What types of motors are suitable for this soft starter?

It is intended for three-phase squirrel-cage asynchronous motors. Before installation, engineers should verify motor rated current, voltage, starting characteristics and the required operating duty.

Q7: Can the PST142-600-70 communicate with a PLC?

Yes. The PST platform supports fieldbus communication through compatible communication accessories. The appropriate communication interface depends on the PLC network and the system configuration.

Q8: Why does the soft starter trip during motor acceleration?

Possible causes include excessive starting current, incorrect motor parameter settings, an overloaded motor, phase loss, an unsuitable current limit or an excessively long starting time. Review the active fault indication before restarting the equipment.

Q9: What should be checked if the motor hums but does not accelerate?

Inspect the incoming three-phase supply, motor wiring, phase balance, mechanical load and starting parameters. Also verify that the selected current limit provides sufficient starting torque for the application.

Q10: How should the PST142-600-70 be maintained?

Maintenance should include inspecting power terminals, checking control wiring, cleaning ventilation passages, reviewing fault records and verifying motor protection settings. All inspection work should be performed by qualified personnel after appropriate electrical isolation.