Ingersoll Rand 47625674001 40068389 8,000-Hour Maintenance and Breather Element Configuration
Ingersoll Rand 47625674001 40068389 8,000-Hour Maintenance and Breather Element Configuration
0.0
Points
Brand:Ingersoll Rand Item No.:47625674001 40068389 Product Origin:USA Product Dimensions:110 × 66.8 × 50 mm Product Weight:0.11 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Ingersoll Rand 47625674001 40068389 8,000-Hour Maintenance and Breather Element Configuration combines the 47625674001 scheduled maintenance reference with the specified 40068389 breather element. This provides a consolidated reference for planned compressor maintenance where the breather component is also required as part of the service preparation.
The 47625674001 reference is associated with an 8,000-hour water-cooled maintenance service interval. The 40068389 component is identified as a breather element used within applicable Ingersoll Rand compressor systems, supporting filtration in the designated breathing circuit.
For equipment operating continuously in industrial environments, maintaining the breather system alongside scheduled service work can help preserve the intended airflow path and reduce contamination-related loading. Exact applicability should be confirmed against the compressor model, serial number, and current Ingersoll Rand parts documentation before installation.
Technical Specifications
Specification
Details
Brand
Ingersoll Rand
Complete Configuration
47625674001 40068389
Primary Maintenance Reference
47625674001
Maintenance Kit Type
8,000-hour water-cooled maintenance kit
Associated Component
40068389
Component Type
Breather Element
Primary Function
Scheduled compressor maintenance and breathing-circuit filtration
2,000-hour maintenance kit for applicable Ingersoll Rand configurations
47625672001
4,000-hour maintenance package for applicable Ingersoll Rand configurations
47625673001
8,000-hour air-cooled maintenance package for applicable configurations
40068371
Alternative breather-element reference used in applicable Ingersoll Rand compressor configurations
Where It Excels in Industrial Use
• Designed for scheduled 8,000-hour maintenance on applicable Ingersoll Rand compressor configurations, combining the 47625674001 maintenance reference with the specified 40068389 breather element.
• Provides a consolidated service configuration for industrial compressed-air installations where long-interval maintenance and breather-system condition are important to reliable operation.
• Supports maintenance programs that address both scheduled service requirements and replacement of the breather element used within the compressor system.
• Suitable for production facilities, process-air systems, utilities, and other industrial environments where compressors operate for extended duty cycles.
• Helps maintenance personnel organize service parts around a defined operating-hour interval while retaining the correct component reference for the breathing circuit.
Key Strengths at a Glance
• Extended service interval: 47625674001 is identified as an 8,000-hour water-cooled maintenance kit reference for applicable Ingersoll Rand compressor configurations.
• Breather-element integration: 40068389 is an Ingersoll Rand breather element used within the applicable compressor breathing system.
• Complete configuration reference: The two part numbers are presented as one requested maintenance configuration for service and procurement purposes.
• Contamination control: A properly maintained breather element helps control particulate entry through the designated breathing path.
• Maintenance planning: Combining the scheduled maintenance reference with the specified breather element simplifies preparation for planned service.
Technical FAQs
1. What is the 47625674001 40068389 configuration used for?
It combines the 47625674001 8,000-hour maintenance reference with the specified 40068389 breather element as one complete maintenance configuration for applicable Ingersoll Rand compressor equipment.
2. What is 47625674001?
47625674001 is identified as an 8,000-hour water-cooled maintenance kit reference for applicable Ingersoll Rand compressor configurations.
3. What is the function of 40068389?
40068389 is an Ingersoll Rand breather element used to provide filtration within the applicable compressor breathing circuit.
4. Why is the breather element important?
The breather element helps control contamination entering the designated breathing path while allowing the system to maintain its intended airflow and pressure-equalization function.
5. Which compressor models can use this configuration?
Compatibility depends on the compressor model, production configuration, and serial number. The applicable equipment documentation should be checked before ordering or installing the complete configuration.
6. What should be checked before installing 40068389?
The technician should verify the compressor identification, existing breather arrangement, part number, housing interface, sealing surfaces, and airflow path before installation.
7. What can happen if the breather element becomes restricted?
A heavily loaded breather element can increase airflow resistance and interfere with the intended breathing function, potentially contributing to abnormal pressure or operating conditions.
8. What operating conditions can shorten breather-element service life?
High airborne contamination, dusty surroundings, oil or vapor exposure, and extended operation can increase loading and may require inspection more frequently than the standard maintenance interval.
9. Should 40068389 be cleaned or replaced during scheduled maintenance?
The element should be inspected and replaced according to the applicable Ingersoll Rand maintenance procedure rather than cleaned and reused unless the equipment documentation specifically permits reuse.
10. What information should be recorded after servicing this configuration?
Maintenance records should include the compressor operating hours, service date, installed part numbers, inspection findings, and any abnormal conditions identified during the service.