The Bently Nevada 330192-00-25-10-00 3300 XL 8 mm ETR Probe is an armored proximity probe designed for machinery condition monitoring in applications that require extended temperature capability. It combines an 8 mm sensing tip with a 1-meter integral cable, providing a specific configuration for compatible 3300 XL transducer installations.

Using eddy-current sensing technology, the probe detects changes in the gap between its tip and a conductive target. When connected to the appropriate Proximitor sensor, it supports shaft vibration and position measurements used in rotating machinery monitoring and protection systems.

The armored cable offers additional mechanical protection, while the shorter cable configuration can simplify installation where the sensor connection is located nearby. Before replacement or procurement, users should verify the mounting details, cable arrangement, temperature requirements, and compatibility with the existing monitoring system.

We supply Bently Nevada proximity probes and related machinery monitoring components for industrial maintenance, repair, and equipment support. Contact us to request a quotation or confirm availability of the 330192-00-25-10-00.

Technical Specifications

Parameter

Specification

Manufacturer

Bently Nevada

Product Series

3300 XL

Model

330192-00-25-10-00

Product Type

8 mm ETR Proximity Probe

Probe Design

Extended Temperature Range

Sensing Principle

Eddy Current

Probe Tip Diameter

8 mm

Mounting Thread

3/8-24 UNF

Cable Construction

Armored

Integral Cable Length

1 meter

Overall Case Length

2.5 in

Unthreaded Length

0.0 in

Probe Tip Temperature Range

-52°C to +218°C

Cable and Connector Temperature Range

-51°C to +260°C

Matched System Linear Range

2.0 mm (80 mils)

Compatible System

3300 XL 8 mm ETR Proximity Transducer System

Total Length

1 meter

Weight

0.323 kg / 0.71 lb

Recommended Related Models

These models belong to related Bently Nevada 3300 XL proximity probe and transducer product families. Their configurations differ, so confirm the mounting, cable, and temperature requirements before selecting a replacement.

Model

Product Description

330191

3300 XL 8 mm ETR Proximity Probe, without armor

330193

3300 XL 8 mm ETR Proximity Probe, M10 × 1 thread, without armor

330194

3300 XL 8 mm ETR Proximity Probe, M10 × 1 thread, with armor

330180-50-00

3300 XL 8 mm Proximitor Sensor

Popular Related Models

The following models are also associated with the Bently Nevada 3300 XL 8 mm proximity probe family and may be relevant to maintenance or replacement projects.

Model

Product Description

330101

3300 XL 8 mm Proximity Probe, 3/8-24 UNF thread, without armor

330102

3300 XL 8 mm Proximity Probe, 3/8-24 UNF thread, with armor

330103

3300 XL 8 mm Proximity Probe, M10 × 1 thread, without armor

330104

3300 XL 8 mm Proximity Probe, M10 × 1 thread, with armor

330190

3300 XL ETR Extension Cable

For assistance with sourcing, provide the complete probe part number and details of the existing transducer arrangement. This helps ensure the replacement matches the installation requirements.


Applications

The Bently Nevada 330192-00-25-10-00 is an armored 3300 XL 8 mm Extended Temperature Range (ETR) proximity probe designed for non-contact monitoring of rotating machinery. It operates on the eddy-current sensing principle, detecting changes in the distance between the probe tip and a conductive shaft or target surface.

With its 1-meter integral cable, this configuration is suitable for installations where a shorter cable connection is required. Typical applications include:

  • Steam and gas turbines: Monitoring shaft vibration and relative shaft position.

  • Industrial compressors: Supporting condition monitoring of high-speed rotating assemblies.

  • Power generation equipment: Providing measurement signals for machinery protection systems.

  • Centrifugal pumps: Supporting continuous monitoring of rotating shafts.

  • Oil and gas facilities: Providing proximity measurements in demanding industrial environments.

The probe is intended to operate as part of a compatible 3300 XL 8 mm ETR transducer system.


Advantages

Extended Temperature Range Design

The ETR configuration is intended for applications with elevated operating temperatures. Its probe tip and cable assembly have separate temperature limits, allowing engineers to select the appropriate installation arrangement for the operating environment.

Armored Cable Protection

The integral cable features protective armor to help resist mechanical damage during installation and operation. This construction is useful where cable routing may expose the assembly to abrasion or physical contact.

Reliable Non-Contact Sensing

Eddy-current technology measures the gap between the probe tip and a conductive target without requiring direct contact. This makes the probe suitable for continuous shaft monitoring.

Compact 1-Meter Cable Configuration

The 1-meter integral cable provides a shorter connection arrangement for installations where the required routing distance is limited. It must be matched with the appropriate extension cable and Proximitor sensor configuration.

Identifiable Replacement Configuration

The complete part number distinguishes this probe from other 3300 XL 8 mm ETR versions. Checking the cable length, mounting arrangement, and system compatibility before ordering helps reduce replacement errors.


Technical FAQs

Q1: What is the function of the Bently Nevada 330192-00-25-10-00?

A: It is an 8 mm ETR proximity probe used for non-contact measurement of shaft vibration and position. It detects changes in the gap between the probe tip and a conductive target and works with a compatible Proximitor sensor.

Q2: What does ETR stand for?

A: ETR means Extended Temperature Range. It identifies a probe configuration designed for applications requiring higher temperature capability than standard proximity probe arrangements. The applicable temperature limits of the probe tip, cable, and connector should all be considered.

Q3: What is the difference between this model and the 5-meter version?

A: The key configuration difference is the integral cable length. The 330192-00-25-10-00 has a 1-meter cable, while the 330192-00-25-50-00 has a 5-meter cable. The required system cable arrangement must be checked before selecting either version.

Q4: Does this probe use eddy-current technology?

A: Yes. It uses eddy-current sensing to detect changes in the distance between the probe tip and a conductive target. The compatible Proximitor sensor converts the probe response into a signal for the machinery monitoring system.

Q5: Is the 330192-00-25-10-00 suitable for turbine monitoring?

A: It can be used in compatible turbine monitoring applications where an 8 mm ETR proximity probe is specified. The final selection should account for the turbine's operating temperature, shaft material, mounting arrangement, and complete transducer system requirements.

Q6: What type of cable protection does this model provide?

A: This model has an armored integral cable. The armor helps protect the cable from mechanical wear and physical damage, although appropriate routing and installation practices are still necessary.

Q7: Which Proximitor sensor is compatible with this probe?

A: It must be used with a compatible Bently Nevada 3300 XL 8 mm ETR Proximitor sensor. The complete transducer configuration, including extension cable requirements, should be verified before installation.

Q8: What should technicians inspect before installing the probe?

A: Inspect the sensing tip, cable armor, connector, and mounting threads for visible damage. Confirm that the probe part number matches the equipment documentation and that the selected sensor and extension cable are suitable for the intended configuration.

Q9: What can cause an incorrect or unstable proximity reading?

A: Potential causes include incorrect probe gap, damaged cable insulation, loose connectors, unsuitable target material, electrical interference, or a mismatched Proximitor sensor. Checking the complete measurement chain is recommended when troubleshooting signal problems.

Q10: Can this model directly replace another 3300 XL 8 mm probe?

A: Not in every case. Different models may have different cable lengths, mounting threads, armor configurations, or temperature ratings. Confirm the complete part number and system requirements before using it as a replacement.