Schneider PLC

  1. Home
  2. Products
  3. Schneider PLC
  4. Schneider MT16H1 Breaker
Schneider MT16H1 Breaker

Schneider MT16H1 Breaker

0.0
Points

Brand:Schneider PLC
Item No.:MT16H1
Product Origin:France
Product Dimensions:322 x 277 x 288 mm
Product Weight:30 kg
Payment:T/T, Western Union, Credit Card
Goods_stock:15
Shipping Port:Xiamen, China
Lead Time:1-3 Days
Condition:Brand New And Original
Warranty:1 Year
Certificate:COO

Add to cart


Introduction to the Schneider MT16H1

The Schneider MT16H1 Circuit Breaker is an industrial electrical distribution component associated with the Masterpact MT range. It is intended for use in low-voltage power systems where dependable switching, circuit protection, and maintenance flexibility are important.

In modern industrial facilities, circuit breakers play a critical role in maintaining electrical system stability. A properly selected breaker helps isolate faulty circuits, protect downstream equipment, and support safe maintenance operations.

The MT16H1 is relevant to industrial users who maintain Schneider Electric Masterpact equipment and require compatible components for existing switchgear installations. Its selection should always be based on the actual electrical characteristics and mechanical configuration of the original equipment.

For industrial distributors, maintenance contractors, and engineering procurement teams, the complete model identification is essential when sourcing this breaker. Confirming the trip unit, accessories, and electrical ratings before purchasing helps minimize compatibility problems and unnecessary downtime.

Technical Specifications and Product Data

Specification

Details

Brand

Schneider Electric

Model Number

MT16H1

Product Name

Masterpact MT Circuit Breaker

Product Type

Low-Voltage Circuit Breaker

Product Series

Masterpact MT

Main Application

Industrial Power Distribution

Switching Function

Circuit Switching and Isolation

Protection Function

Depends on Installed Trip Unit

Dimensions (H × W × D)

322 × 277 × 288 mm

Weight

30 kg

Weight in Pounds

66.14 lb

Mechanical Dimensions

Parameter

Measurement

Height

322 mm

Width

277 mm

Depth

288 mm

Net Weight

30 kg

Equivalent Weight

66.14 lb

The dimensions and weight are based on the supplied product information. Rated current, breaking capacity, operating voltage, and trip-unit specifications should be confirmed using the complete nameplate and product configuration.

Recommended Related Schneider Electric Models

For buyers maintaining Masterpact MT circuit breaker installations, the following model references may be useful when comparing equipment requirements and sourcing related components.

Model

Product Description

MT08H1

Masterpact MT Circuit Breaker

MT10H1

Masterpact MT Circuit Breaker

MT12H1

Masterpact MT Circuit Breaker

MT20H1

Masterpact MT Circuit Breaker

MT25H1

Masterpact MT Circuit Breaker

MT32H1

Masterpact MT Circuit Breaker

These models belong to the related Masterpact MT identification range. They should not be treated as direct replacements without checking electrical and mechanical compatibility.

Popular Masterpact Circuit Breakers for Industrial Procurement

Schneider Electric offers different Masterpact circuit breaker configurations for industrial and commercial power distribution systems. The following references are useful for equipment sourcing and maintenance inquiries.

Model

Product Description

MT12H2

Masterpact MT Circuit Breaker

MT16H2

Masterpact MT Circuit Breaker

MT25H2

Masterpact MT Circuit Breaker

MT32H2

Masterpact MT Circuit Breaker

MVS06N

Masterpact MVS Circuit Breaker

MVS08N

Masterpact MVS Circuit Breaker

Schneider MT16H1 Circuit Breaker – Reliable Industrial Equipment Sourcing

Finding the correct circuit breaker is essential for maintaining the reliability of industrial power distribution systems. We support industrial buyers, electrical contractors, and maintenance professionals with Schneider Electric equipment sourcing.

Contact us with your MT16H1 model reference and configuration details for product availability, technical confirmation, and procurement assistance.


Industrial Applications and System Integration

The Schneider MT16H1 Circuit Breaker is designed for integration into industrial low-voltage power distribution systems where dependable circuit switching and electrical protection are essential. As part of the Schneider Electric Masterpact MT product family, it is intended for demanding electrical installations that require reliable power management and equipment protection.

Typical application areas include:

  • Industrial Switchgear: Integration into main distribution panels and low-voltage switchgear assemblies.

  • Manufacturing Plants: Protection of electrical distribution networks supplying production machinery and industrial equipment.

  • Power Distribution Centers: Application in electrical infrastructure where controlled switching and circuit isolation are required.

  • Commercial Infrastructure: Suitable for evaluating in large building distribution systems and electrical installations.

  • Industrial Maintenance Projects: Used in replacement and maintenance programs involving compatible Masterpact MT equipment.


Major Advantages and Product Highlights

1. Dependable Electrical Protection

The MT16H1 is intended for applications requiring reliable interruption of abnormal electrical currents. Its protection performance depends on the installed trip unit and the selected protection settings.

2. Suitable for Industrial Distribution Systems

Its Masterpact MT platform makes it relevant to industrial switchgear and power distribution applications where equipment reliability is a priority.

3. Flexible Protection Configuration

Depending on the exact product configuration, compatible protection accessories and trip-unit arrangements can support different electrical protection requirements.

4. Reliable Switching Performance

The circuit breaker provides a switching and isolation solution for appropriately designed electrical distribution assemblies.

5. Long-Term Equipment Maintenance

For facilities maintaining established Schneider Electric distribution systems, sourcing the correct MT16H1 configuration can help reduce unnecessary modifications during equipment replacement.

6. Professional Industrial Application

Its application in power distribution infrastructure makes it a relevant component for electrical contractors, panel builders, maintenance teams, and industrial equipment suppliers.


Technical FAQs

Q1: What is the main purpose of the Schneider MT16H1 Circuit Breaker?

A: The MT16H1 is designed for electrical switching and circuit protection in compatible low-voltage distribution systems. It helps protect electrical installations against abnormal current conditions according to its installed protection configuration.

Q2: What is the difference between overload protection and short-circuit protection?

A: Overload protection responds to excessive current sustained over time, while short-circuit protection addresses significantly higher fault currents that require rapid interruption. Both functions depend on the installed trip unit and its settings.

Q3: Can the MT16H1 be installed in an existing Masterpact MT switchboard?

A: It may be suitable if the switchboard is designed for the corresponding breaker frame, mounting arrangement, electrical ratings, and connection configuration. Compatibility must be confirmed before installation.

Q4: How should the protection settings be selected?

A: Protection settings should be determined according to the connected load, cable capacity, system fault level, and coordination requirements. Qualified electrical engineers should verify the settings before commissioning.

Q5: What is the function of an electronic trip unit?

A: An electronic trip unit monitors electrical current and evaluates it against configured protection thresholds. When a detected condition exceeds the applicable settings, it initiates the circuit breaker's opening mechanism.

Q6: Can auxiliary contacts be used with the MT16H1?

A: Compatible auxiliary contacts can provide remote indication of breaker status, such as open, closed, or tripped conditions. The correct accessory type must be confirmed for the specific breaker version.

Q7: What should be considered when connecting the breaker to a busbar system?

A: Important considerations include rated current, busbar dimensions, connection orientation, electrical clearances, temperature rise, and short-circuit withstand capability. All connections must follow the approved installation requirements.

Q8: Why might the circuit breaker fail to close?

A: Possible causes include an incomplete spring-charging sequence, an active trip condition, an electrical or mechanical interlock, undervoltage release activation, or a control circuit fault. The operating mechanism and control accessories should be inspected by qualified personnel.

Q9: Is the MT16H1 suitable for remote monitoring?

A: Remote monitoring depends on the installed auxiliary contacts, communication accessories, and compatible monitoring infrastructure. The complete configuration should be checked before integrating it into a supervisory system.

Q10: What information is required when ordering a replacement MT16H1?

A: Buyers should provide the complete model reference, rated current, rated operational voltage, breaking capacity, pole arrangement, trip-unit type, mounting configuration, and accessory details. These parameters help ensure that the replacement matches the existing installation.


Look forward to your comments!Comment
Latest comments
Tags:
Need Assistance? Chat with Us on WhatsApp!
Need Assistance? Click to Inquire
Back to top