Brand:Schneider PLC Item No.:MT16H1 Product Origin:France Product Dimensions:322 x 277 x 288 mm Product Weight:30 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Schneider MT16H1 Circuit Breaker is an industrial electrical distribution component associated with the Masterpact MT range. It is intended for use in low-voltage power systems where dependable switching, circuit protection, and maintenance flexibility are important.
In modern industrial facilities, circuit breakers play a critical role in maintaining electrical system stability. A properly selected breaker helps isolate faulty circuits, protect downstream equipment, and support safe maintenance operations.
The MT16H1 is relevant to industrial users who maintain Schneider Electric Masterpact equipment and require compatible components for existing switchgear installations. Its selection should always be based on the actual electrical characteristics and mechanical configuration of the original equipment.
For industrial distributors, maintenance contractors, and engineering procurement teams, the complete model identification is essential when sourcing this breaker. Confirming the trip unit, accessories, and electrical ratings before purchasing helps minimize compatibility problems and unnecessary downtime.
Technical Specifications and Product Data
Specification
Details
Brand
Schneider Electric
Model Number
MT16H1
Product Name
Masterpact MT Circuit Breaker
Product Type
Low-Voltage Circuit Breaker
Product Series
Masterpact MT
Main Application
Industrial Power Distribution
Switching Function
Circuit Switching and Isolation
Protection Function
Depends on Installed Trip Unit
Dimensions (H × W × D)
322 × 277 × 288 mm
Weight
30 kg
Weight in Pounds
66.14 lb
Mechanical Dimensions
Parameter
Measurement
Height
322 mm
Width
277 mm
Depth
288 mm
Net Weight
30 kg
Equivalent Weight
66.14 lb
The dimensions and weight are based on the supplied product information. Rated current, breaking capacity, operating voltage, and trip-unit specifications should be confirmed using the complete nameplate and product configuration.
Recommended Related Schneider Electric Models
For buyers maintaining Masterpact MT circuit breaker installations, the following model references may be useful when comparing equipment requirements and sourcing related components.
Model
Product Description
MT08H1
Masterpact MT Circuit Breaker
MT10H1
Masterpact MT Circuit Breaker
MT12H1
Masterpact MT Circuit Breaker
MT20H1
Masterpact MT Circuit Breaker
MT25H1
Masterpact MT Circuit Breaker
MT32H1
Masterpact MT Circuit Breaker
These models belong to the related Masterpact MT identification range. They should not be treated as direct replacements without checking electrical and mechanical compatibility.
Popular Masterpact Circuit Breakers for Industrial Procurement
Schneider Electric offers different Masterpact circuit breaker configurations for industrial and commercial power distribution systems. The following references are useful for equipment sourcing and maintenance inquiries.
Finding the correct circuit breaker is essential for maintaining the reliability of industrial power distribution systems. We support industrial buyers, electrical contractors, and maintenance professionals with Schneider Electric equipment sourcing.
Contact us with your MT16H1 model reference and configuration details for product availability, technical confirmation, and procurement assistance.
Industrial Applications and System Integration
The Schneider MT16H1 Circuit Breaker is designed for integration into industrial low-voltage power distribution systems where dependable circuit switching and electrical protection are essential. As part of the Schneider Electric Masterpact MT product family, it is intended for demanding electrical installations that require reliable power management and equipment protection.
Typical application areas include:
Industrial Switchgear: Integration into main distribution panels and low-voltage switchgear assemblies.
Manufacturing Plants: Protection of electrical distribution networks supplying production machinery and industrial equipment.
Power Distribution Centers: Application in electrical infrastructure where controlled switching and circuit isolation are required.
Commercial Infrastructure: Suitable for evaluating in large building distribution systems and electrical installations.
Industrial Maintenance Projects: Used in replacement and maintenance programs involving compatible Masterpact MT equipment.
Major Advantages and Product Highlights
1. Dependable Electrical Protection
The MT16H1 is intended for applications requiring reliable interruption of abnormal electrical currents. Its protection performance depends on the installed trip unit and the selected protection settings.
2. Suitable for Industrial Distribution Systems
Its Masterpact MT platform makes it relevant to industrial switchgear and power distribution applications where equipment reliability is a priority.
3. Flexible Protection Configuration
Depending on the exact product configuration, compatible protection accessories and trip-unit arrangements can support different electrical protection requirements.
4. Reliable Switching Performance
The circuit breaker provides a switching and isolation solution for appropriately designed electrical distribution assemblies.
5. Long-Term Equipment Maintenance
For facilities maintaining established Schneider Electric distribution systems, sourcing the correct MT16H1 configuration can help reduce unnecessary modifications during equipment replacement.
6. Professional Industrial Application
Its application in power distribution infrastructure makes it a relevant component for electrical contractors, panel builders, maintenance teams, and industrial equipment suppliers.
Technical FAQs
Q1: What is the main purpose of the Schneider MT16H1 Circuit Breaker?
A: The MT16H1 is designed for electrical switching and circuit protection in compatible low-voltage distribution systems. It helps protect electrical installations against abnormal current conditions according to its installed protection configuration.
Q2: What is the difference between overload protection and short-circuit protection?
A: Overload protection responds to excessive current sustained over time, while short-circuit protection addresses significantly higher fault currents that require rapid interruption. Both functions depend on the installed trip unit and its settings.
Q3: Can the MT16H1 be installed in an existing Masterpact MT switchboard?
A: It may be suitable if the switchboard is designed for the corresponding breaker frame, mounting arrangement, electrical ratings, and connection configuration. Compatibility must be confirmed before installation.
Q4: How should the protection settings be selected?
A: Protection settings should be determined according to the connected load, cable capacity, system fault level, and coordination requirements. Qualified electrical engineers should verify the settings before commissioning.
Q5: What is the function of an electronic trip unit?
A: An electronic trip unit monitors electrical current and evaluates it against configured protection thresholds. When a detected condition exceeds the applicable settings, it initiates the circuit breaker's opening mechanism.
Q6: Can auxiliary contacts be used with the MT16H1?
A: Compatible auxiliary contacts can provide remote indication of breaker status, such as open, closed, or tripped conditions. The correct accessory type must be confirmed for the specific breaker version.
Q7: What should be considered when connecting the breaker to a busbar system?
A: Important considerations include rated current, busbar dimensions, connection orientation, electrical clearances, temperature rise, and short-circuit withstand capability. All connections must follow the approved installation requirements.
Q8: Why might the circuit breaker fail to close?
A: Possible causes include an incomplete spring-charging sequence, an active trip condition, an electrical or mechanical interlock, undervoltage release activation, or a control circuit fault. The operating mechanism and control accessories should be inspected by qualified personnel.
Q9: Is the MT16H1 suitable for remote monitoring?
A: Remote monitoring depends on the installed auxiliary contacts, communication accessories, and compatible monitoring infrastructure. The complete configuration should be checked before integrating it into a supervisory system.
Q10: What information is required when ordering a replacement MT16H1?
A: Buyers should provide the complete model reference, rated current, rated operational voltage, breaking capacity, pole arrangement, trip-unit type, mounting configuration, and accessory details. These parameters help ensure that the replacement matches the existing installation.