Brand:Schneider PLC Item No.:NT12H1 Product Origin:France Product Dimensions:322 x 288 x 277 mm Product Weight:30 kg Payment:T/T, Western Union, Credit Card Goods_stock:15 Shipping Port:Xiamen, China Lead Time:1-3 Days Condition:Brand New And Original Warranty:1 Year Certificate:COO
The Schneider NT12H1 Breaker is a low-voltage circuit breaker intended for integration into electrical power distribution equipment. It serves as part of the protection and switching arrangement in installations where electrical circuits must be managed according to defined operating and fault conditions.
For industrial maintenance departments, panel builders, and electrical system integrators, choosing the correct breaker requires careful attention to the complete product configuration. Electrical ratings, trip unit characteristics, connection arrangements, mounting requirements, and accessory compatibility all influence whether a unit is suitable for a particular installation.
When purchasing the NT12H1 for an existing system, it is advisable to compare the complete model reference and product nameplate with the original equipment documentation. This helps reduce compatibility problems during replacement and maintenance work.
Technical Specifications
Parameter
Specification
Brand
Schneider Electric
Model
NT12H1
Product Type
Circuit Breaker
Product Category
Low-Voltage Circuit Protection
Dimensions
322 × 288 × 277 mm
Weight
30 kg / 66.14 lb
Application
Low-Voltage Power Distribution
Installation
Compatible Electrical Distribution Assembly
Note: Rated current, operating voltage, breaking capacity, trip unit type, and accessory configuration should be confirmed using the specific product nameplate and manufacturer documentation.
Recommended Related Models
The following Schneider Electric circuit breaker models may be useful for comparing equipment within related low-voltage distribution ranges.
Model
Product Description
Schneider MT12H1
MT Series Circuit Breaker
Schneider MT16H1
MT Series Circuit Breaker
Schneider MT20H1
MT Series Circuit Breaker
Schneider MT25H1
MT Series Circuit Breaker
Schneider MT32H1
MT Series Circuit Breaker
These models are related product references, not confirmed direct replacements for the NT12H1. Verify electrical and mechanical compatibility before selecting an alternative.
Popular Related Models
The following Schneider Electric circuit breaker references may also be relevant to industrial electrical equipment sourcing:
Model
Product Description
Schneider MT06NA
MT Series Circuit Breaker
Schneider MT08NA
MT Series Circuit Breaker
Schneider MT10NA
MT Series Circuit Breaker
Schneider MT12N2
MT Series Circuit Breaker
Schneider NW08N1
NW Series Circuit Breaker
For replacement projects, always compare the complete model number, rated current, breaking capacity, trip unit, mounting arrangement, and terminal configuration before ordering.
Applications
The Schneider NT12H1 Breaker is intended for low-voltage power distribution systems that require circuit switching and electrical fault protection. It can be considered for industrial and commercial installations where the breaker must operate as part of a properly coordinated distribution network.
Typical application areas include:
Industrial Power Distribution: Used in electrical distribution assemblies supplying production equipment, machinery, and plant utilities.
Power Feeder Protection: Supports protection arrangements for distribution feeders when selected according to the system's electrical requirements.
Commercial Facilities: Can be integrated into compatible low-voltage distribution systems in commercial and institutional buildings.
Switchboard Assemblies: Suitable for evaluation in switchboards and electrical cabinets designed for the corresponding breaker configuration.
Equipment Maintenance: Relevant to maintenance and replacement projects involving compatible Schneider Electric circuit breaker installations.
Key Product Characteristics
The NT12H1 is intended for electrical distribution applications where protection coordination, system compatibility, and maintenance considerations are important.
Circuit Switching and Protection: Provides a switching and protective function within an appropriately designed low-voltage distribution system.
Industrial Application: Suitable for consideration in power distribution installations serving industrial equipment and electrical infrastructure.
Protection Coordination: Can form part of a coordinated protection scheme when its characteristics are matched with upstream and downstream devices.
Equipment Identification: The complete model reference helps maintenance teams distinguish the required breaker during sourcing and replacement.
System Integration: Selection can be evaluated against existing switchboard mounting and connection requirements.
Maintenance Planning: Supports equipment inspection and servicing according to the applicable manufacturer procedures.
Technical FAQs
Q1: What is the main purpose of the Schneider NT12H1 Breaker?
It is intended to provide circuit switching and protection in low-voltage electrical distribution systems. Its actual protective functions depend on the installed trip unit and configuration.
Q2: What electrical ratings need to be verified before installation?
Confirm rated operational voltage, rated current, frequency, short-circuit breaking capacity, pole arrangement, and trip unit characteristics.
Q3: Is the NT12H1 suitable for industrial distribution equipment?
It can be considered for compatible industrial distribution applications. Its suitability depends on the electrical load, prospective fault current, environmental conditions, and switchboard design.
Q4: How does the trip unit protect an electrical circuit?
The trip unit monitors circuit conditions and initiates breaker tripping when specified protection thresholds are exceeded. Available functions and settings depend on the installed trip unit.
Q5: What is the importance of protection selectivity?
Selectivity helps ensure that the protective device closest to a fault operates first, limiting unnecessary interruptions to other parts of the electrical system.
Q6: Can the NT12H1 be used in a motor feeder circuit?
It may be considered as part of a suitable motor feeder protection arrangement. Motor starting characteristics, overload protection, short-circuit protection, and coordination with contactors or motor protection devices must be evaluated.
Q7: What could cause the breaker to trip during normal operation?
Potential causes include excessive load current, transient conditions, incorrect protection settings, wiring faults, insulation deterioration, or problems with connected equipment. The cause should be identified before resetting.
Q8: How should the breaker be inspected during routine maintenance?
Qualified personnel should check the external condition, terminals, connections, operating mechanism, and relevant protection functions according to the manufacturer's maintenance instructions.
Q9: Can another Schneider circuit breaker model replace the NT12H1?
A similar product designation does not establish interchangeability. Replacement selection must consider rated current, breaking capacity, frame compatibility, trip unit, mounting arrangement, and connection details.
Q10: What safety procedures are required before servicing the breaker?
Isolate all power sources, implement lockout/tagout, verify the absence of voltage, and follow the manufacturer's safety procedures. Electrical servicing should only be performed by qualified personnel.